total St. Louis Ribs (2.75lb.) 126 pieces 346 lb. total w/Optional Rib Racks 270 pieces 742 lb total Chicken (3lb.) 156 pieces 468 lb. total Brisket (12 lb.) 48 pieces 576 lb. total Spare Ribs (3.5lb.) 90 pieces 315 lb. total SPK-700-SL Electrical Requirements: 120 volts AC, 60 hertz, 1 phase, 15 amp wiring required. Gas Requirements: 75,000 btu, 1/2 NPT Construction: Inner Liner: 14 gauge H.R. Steel or 14 gauge Stainless Steel. Exterior: 22-gauge Polished Stainless Steel Firebox: 10 ga. H.R. steel with 10 ga. H.R. firebox door. Uses wood logs or charcoal. Capacity: 3-4 logs 4-6” dia. 12-16” long. Dimensions: 75” tall, 72 3/8” wide, 83 1/4” deep (including covers) w/19” legs Shell Dimensions: 56” tall, 583/8” wide, 75 1/4” long. Food Racks: Rotisserie with six (6) hanger racks, each with three (3) 12”x 48” food racks (18 Total). 72 Sq.Ft. of Cooking Surface. 3 1/2” Spacing between food racks. Air Circulation: Low Velocity Convection Fan. Temperature Range: 100-325 degrees F. Burner: Electronic Pilot Gas Burner (Specify Natural or L.P. gas.) Approvals: UL, ULC, NSF Venting: See back page for venting instructions. 75 1/4" 58 3/8" 83 1/4" 83 1/4" 72 3/8" 75 1/4" 19" 19" 5 1/2" 5 1/2" 29 1/4" 12 1/2" 14" 22" 19" 14" 19" 56" 75" Front View Side View Top View 10" 28 1/2" NOTE: Dimensions Show position of the 10” flue on the optional smoke extractor on the -SLSE Model. NOTE: Drawings Show the Optional Smoke Extractor on SLSE Models. Optional Smoke Extractor Optional Smoke Extractor 11 1/2" Optional Smoke Extractor Electrical Connection for VSP Hood Shown with Optional Digital Controls Electrical Connection for VSP Hood 2 1/2" SPK-700-SL with recommended optional VSP Vent Hood System. 1 2 3 SPECIFY ROOF PITCH 4 5 6 1 2 3 SPECIFY ROOF PITCH 4 5 6 SPK-700-SL VENTING INSTALLATION VSP HOOD SYSTEM: Purchased through Southern Pride VSP HOODS are U/L Listed to the applicable Southern Pride oven models and are NSF Certified. HOOD SYSTEM TO INCLUDE: 1. Ventilation Hood 2. Two speed fan (1380/2000) 3. Curb with vented extension and hinge kit (Specify roof pitch) 4. Grease capture trough 5. Combustion chamber flue vent SUPPLIED BY CUSTOMER: 6. Duct from hood to fan NOTE: If you have a duct longer than 10 feet or an elbow in your duct your installation, it may require a larger capacity exhaust fan. Please specify your duct requirements when ordering the VSP Hood System. ALL MODELS MAY ALSO BE INSTALLED UNDER A CANOPY HOOD RATED FOR COMMERCIAL COOKING APPLIANCES. NOTE: THE SIX INCH ALL FUEL CHIMNEY SHOULD EXTEND AT LEAST3’ ABOVE THE THROUGH THE WALL HIGHEST SIDE OF THE ROOF OPENING RAIN AND BE ATLEAST2’ HIGHER THAN ANY CAP DIRECT VENT INSTALLATION 10 ” ALL FUEL SMOKE EXTR ACTOR CH IMNEY P ORTI ON OF THE BUILDING WI THIN 10’. HORIZON TAL. 6” ALL FUEL CHIMNEY EXHAUS T FAN NOTE: THE 10 ” ALL FUEL SMOKE EX- TRACTOR CHIMNEY TERMIN ATES AT THE ROOF C URB NOTE 1. When installing an Oven through a wall constructed of combustible material, use the Southern Pride Insulation Kit between the oven and the wall. 2. The room that the face of the oven is installed into should have a balanced or positive air pressure. If the room has negative air pressure, smoke could escape into the room during operation. SUPPLIED BY SOUTHERN PRIDE: (*) Smoke Extractor Damper with 10” chimney adapter plate SUPPLIED BY CUSTOMER: 6” All Fuel Chimney, 6” Rain Cap, and all accessories necessary for installation of the 6” chimney. 10” All Fuel Chimney, Exhaust Fan (NOTE: Fan must be listed for use as a commercial kitchen ventilator), fan curb, and all accessories necessary for installation of the smoke extractor system. The oven’s minimum clearances from combustible materials are 18" on left side, 24" on right, 18" on top, 48" from front, and 2" on back. Minimum clearances are 18" to chimney connector and to smoke extractor chimney connector. Floor may be constructed of a combustible material. (Note: minimum clearance dimensions are from the oven cabinet, not from component cover.) (If provision is made for access to service, minimum clearance can be reduced to 2" on left side.) May be installed through a combustible wall with zero clearance with BBR kit No. 2099. ANY VENTILATION SYSTEM MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES. CONSULT WITH LOCAL OFFICIALS AND A COMMERCIAL KITCHEN VENTILATION CONTRACTOR PRIOR TO INSTALLATION. Southern Pride Distributing, L.L.C. Phone: 618-997-9348 2102 East Main Street - Marion, Illinois 62959 Fax: 618-993-5960 sales@sopride.com service@sopride.com parts@sopride.com Sales: 800-851-8180 Servi...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias