Log:
Assessments - 4, GPA: 3.8 ( )

Instruções de Operação Wayne, Modelo WLS200

Fabricante : Wayne
Arquivo Tamanho: 265.25 kb
Arquivo Nome :
Língua de Ensino: enesfr
Ir para baixar



Facilidade de uso


The water inside the pump could boil and damage the pump. Maintenance Maintain adequate ventilation for the pump motor. The motor bearings are permanently lubricated at the factory. Additional lubrication is not required. DRAINING FOR WINTER Always protect pump and piping against freezing temperatures. If there is any danger of freezing, drain the system. To drain the system: 1. Remove the pipe plug from the discharge tee. 2. Remove the 1/4” plug from the lower front face of the pump. 3. Drain all piping below the frost line. Lift in Feet 2 HP Pump Capacity in GPH Operating Pressure (psi) 10 20 30 40 Lift in Feet 1 HP Pump Capacity in GPH Operating Pressure (psi) 10 20 30 5 10 15 20 25 4410 4180 3830 3680 3340 3920 3520 3340 3060 2720 2570 2300 1780 1160 1260 5 10 15 20 25 5980 5410 5230 4120 3980 5560 5220 4980 3840 3600 4310 4090 3900 3510 3300 3060 2880 2570 2210 0 3 WLS75, WLS100 Operating Instructions and Parts Manual WLS150, WLS200 WIRING CHART - RECOMMENDED WIRE AND FUSE SIZES Distance in Feet From Motor to Supply Max. Fuse 0 51 101 201 Load Rating 50 100 200 300 Model HP Volts Amps Amps (AWG Wire Size) WLS75 3/4 115 13.5 20 12 12 10 10 230 7.0 15 14 14 12 12 WLS100 1 115 14.8 20 12 12 10 10 230 7.4 15 14 14 12 12 WLS150 1-1/2 115 17.0 30 10 10 8 8 230 8.5 15 14 14 12 12 WLS200 2 230 12.0 15 14 14 12 12 psi Friction Loss in 100 Feet of Plastic Pipe* Pipe (Gallons per Hour) Size 1200 1500 1800 2400 3000 3600 4800 6000 7200 1-1/4 2.6 3.9 5.5 9.4 14.1 1-1/2 1.2 1.9 2.6 4.4 6.7 9.4 15.9 2 0.6 0.8 1.3 2.0 2.8 4.7 7.1 10.0 2-1/2 0.6 0.8 1.2 1.3 3.0 4.2 * Multiply by 1.8 for steel pipe Troubleshooting Chart Symptom Possible Cause(s) Corrective Action Motor will not run 1. Disconnect switch is off 2. Fuse is blown 3. Starting switch is defective 4. Wires at motor are loose, disconnected or wired incorrectly 1. Be sure switch is on 2. Replace fuse 3. Replace starting switch 4. Refer to wiring instructions. Check and tighten all wiring Capacitor voltage may be hazardous. To discharge capacitor, touch short capacitor terminals with an insulated screwdriver. BE SURE to hold handle of screwdriver while making contact with capacitor terminals. Motor runs hot and 1. Motor is wired incorrectly 1. Refer to wiring instructions overload kicks off 2. Voltage is too low 2. Check with power company. Install heavier wiring if wire size is too small (See wiring chart) 3. Pump house not properly vented 3. Be sure pump has sufficient ventilation to cool the motor Motor runs but no water is delivered Note: Check prime before looking for other causes. Unscrew priming plug and see if water is in priming hole. 1. Pump in new installation did not pick up prime through: a. Improper priming b. Air leaks c. Leaking foot valve 2. Pump has lost prime through: a. air leaks b. water level below suction of pump 3. Impeller is plugged 4. Check valve or foot valve is stuck in closed position 5. Pipes are frozen 6. Foot valve and/or strainer are buried in sand or mud 1. New installation: a. Re-prime according to instructions b. Check all connections on suction line c. Replace foot valve 2. Existing installations: a. Check all connections on suction line and shaft seal b. Lower suction line into water and re-prime. If receding water level in well exceeds suction lift, a deep well pump is needed 3. Clean impeller 4. Replace check valve or foot valve 5. Thaw pipes. Bury pipe below frost line. Heat pit or pump house 6. Raise foot valve and/or stainer above well bottom Pump does not 1. Water level in well is lower than 1. A deep well jet pump my be needed (over 25 ft. (7.6M) to deliver water to full estimated water) capacity 2. Steel piping (if used) is corroded 2. Replace with plastic pipe where possible, otherwise with new or limed, causing excess friction steel pipe 3. Piping is too small in size 3. Use larger piping 4 WLS75, WLS100 Operating Instructions and Parts Manual WLS150, WLS200 For Replacement Parts or Technical Assistance, call 1-800-237-0987 Please provide following information: - Model number -Serial number (if any) -Part description and number as shown in parts list 1 3 2 Address parts correspondence to: Wayne Water Systems 101 Production Drive Harrison, OH 45030 U.S.A. 7 4 5 6 8 9 10 11 Ref. Part Number for Models: No. Description WLS75 WLS100 WLS150 WLS200 Qty. 1 Motor 32031-001 32015-001 32020-001 32021-001 1 2 3/8”-16 x 1” Hex cap screw 16334 16334 16334 16334 4 3 Sealplate 41011-001 41011-001 41011-001 41011-001 1 4 Shaft seal assembly 15559-002 15559-002 15559-002 15559-002 1 5 Impeller 29806-001 29805-001 29804-001 29803-001 1 6 Diffuser 29807-001 29807-001 29807-001 29807-001 1 7 10-24 x 1” Phillips screw 67017-001 67017-001 67017-001 67017-001 3 8 Square ring 19013-001 19013-001 19013-001 19013-001 1 9 Volute 41010-001 41010-001 41010-001 41010-001 1 10 7/16”-16 x 1.25” Hex cap screw 67018 67018 67018 67018 4 11 1/4” NPT Sq. hd. pipe plug 16314-002 16314-002 16314-002 16314-002 1 www....

Este manual também é adequado para os modelos :
Ferramentas para Jardim - WLS150 (265.25 kb)
Ferramentas para Jardim - WLS100 (265.25 kb)
Ferramentas para Jardim - WLS75 (265.25 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias