Log:
Assessments - 3, GPA: 4.7 ( )

Instruções de Operação American Standard, Modelo 3353

Fabricante : American Standard
Arquivo Tamanho: 69.51 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Pictures may not exactly define contour of china FIXTURE MOUNTING Fixture studs should project 1-7/8" (48mm) from face of finished wall. Front View Side View FINISHED WALL 1-7/8" (48mm) (4) STUDS When installed, top of seat is 17" to 19" (432mm to 483mm) from the finished floor. FINISHED WALL 470mm (18-1/2") C/L OF SEAT POST HOLES 140 mm (5-1/2") CENTER 660mm (26") 73mm (2-7/8") 133mm (5-1/4") 191mm (7-1/2") 292mm (11-1/2") (4) 22mm (7/8") HOLES 356mm (14") C/L OF OUTLET 121mm (4-3/4") FINISHED FLOOR 32mm (1-1/4") 1" N.P.T. OR C.W.T. SUPPLY AS REQUIRED TO FLUSH VALVE 330mm (13") 19mm (3/4") 142mm (5-1/4") 83mm (3-1/4") 62mm (2-1/8") 1-1/2" SPUD C/L 229mm (9) FINISHED WALL 470mm (18-1/2") C/L OF SEAT POST HOLES 140mm(5-1/2") CENTERS 660mm (26") 133mm (5-1/4") 191mm (7-1/2") 298mm (11-3/4") (4) 22mm (7/8") DIA. HOLES 356mm (14") C/L OF OUTLET FINISHED FLOOR 32mm (1-1/4") 330mm (13") (3/4") 19mm 133mm(5-1/4" ) 83mm (3-1/4") C/L 229mm (9") 38mm (1-1/2") DIA. HOLE IN WALL 95mm (3-3/4") FOR WALLS UP TO 1" IN THICKNESS FOR EACH INCH ADDITIONAL THICKNESS OF WALL ADD 25mm (1) TO MEASUREMENT SHOWN 89mm (3-1/2") 1" C.W.T. OR N.P.T. SUPPLY AS REQ'D NOT FURNISHED 121mm (4-3/4") VACUUM BREAKER 76mm(3") DIA. HOLE IN WALL FOR 1-1/2" SPUD 254mm (10") 41mm (1-5/8") 38mm (1-1/2") 62mm(2-1/8" ) 184mm (7-1/4") or 381mm (15") or 432mm (17") 184mm (7-1/4") or 381mm (15") or 432mm (17") Product names listed herein are trademarks of AS America, Inc. © AS America, Inc. 2010 7301115-100 Rev. C Place back-up nuts on both bottom bolts, and the top left-hand bolt only. Adjust the two lower back-up nuts so that front face of nuts is flush with finished wall. 3 Using a level, adjust the top left back-up nut so that it is in the same vertical plane as the lower left back-up nut. (If wall surface is irregular, the three back-up nuts must be positioned to allow a minimum 1/16" gap between fixture and wall surface.) 4 Adjust waste horn to project 5/16" (7mm) from finished wall. FINISHED WALL CLOSET CARRIER SYSTEM (3) NUTS WASTE HORN 5/16" (7mm) LEVEL FINISHED WALL 1/16" (2mm) (IRREGULAR WALL SURFACE) NOTE: Bearing nuts and washers must be set to take full loading from the fixture allowing 1/16" (2mm) clearance between fixture and wall. Follow support manufacturer's recommended setting of closet outlet connection. Place felt or neoprene gasket (wax ring not recommended) on closet outlet. When the fixture is installed, closet outlet gasket must be compressed sufficiently to assure a gas and watertight seal. Install bowl on support using cap nuts and fiber washers with the back-up nuts and washers. DO NOT APPLY TOP RIGHT FIBER WASHER AND CAP NUT UNTIL OTHER CAP NUTS HAVE BEEN FIRMLY TIGHTENED USING A WRENCH. Install top right cap nut with fiber washer and run up hand tight. Wrench tighten approximately 1/4 turn. Apply sealant to gap between bowl and finished wall. Remove excess sealant. 5 The following steps require a helper: In the United States: American Standard Brands P.O. Box 682...

Este manual também é adequado para os modelos :
Canalização - 2633.1 (69.51 kb)
Canalização - 2257.001 (69.51 kb)
Canalização - 2634.001 (69.51 kb)
Canalização - 3351 (69.51 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias