Log:
Assessments - 3, GPA: 4 ( )

Instruções de Operação American Standard, Modelo 3475.5

Fabricante : American Standard
Arquivo Tamanho: 1.17 mb
Arquivo Nome : Install_1314.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


*Your new American Standard faucet is designed to work only with the Speed Connect drain. To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin. M968677 Rev. 1.1 Turn off hot and cold water 1 BIDET FAUCET INSTALLATION CAUTION supplies before beginning. Replace UPPER GASKET (8) and WASHER (7) and ESCUTCHEON (6) until it locks against internal stop. Position the side threaded outlet rearward and secure MOUNTING NUT (11). Remove ESCUTCHEON (6), WASHER (7) and UPPER GASKET (8) from TRANSFER VALVE (9). Insert TRANSFER VALVE (9) into the center forward hole of BIDET. HOT COLD BIDET LEDGE 10 4 3 3a 8 9 1 5 2 6 2 SPRAY INSTALLATION Assemble SPRAY BODY (1) to BIDET. Using putty, seal underside of SPRAY BODY FLANGE (2) and secure with NUT (3). Thread SPRAY CAP (9) onto SPRAY BODY (1). Thread SPRAY HOSE (4) with SEAL WASHER (5) to SPRAY BODY (1). Connect other end of HOSE (4) with SEAL WASHER (6) to side outlet NIPPLE (7) of the TRANSFER VALVE (8). PUTTY 6 2 7 8 1 9 Tighten LOCKNUTS (1) with WRENCH (5) (supplied) to secure VALVE BODIES (3, 3a). Install LOCKNUT (1) and RUBBER WASHER (2) onto VALVE BODIES (3, 3a). From under side of mounting surface, install VALVE BODY (3, 3a) through valve mounting holes. Threads of VALVE BODY (3, 3a) should extent at least 5/16 of a inch above mounting surface top. Fig. A. Thread ESCUTCHEON (4) onto VALVE BODIES (3, 3a) until snug against internal stop. If necessary, adjust LOCKNUT (1). Place RUBBER RING (10) into ESCUTCHEON (4). MOUNTING SURFACE 4 10 21 3, 3a 5/16'' MIN. Fig. A. 11 Adjustable Wrench Screwdriver Channel Locks Required tools Tubing Cutter Phillips Screwdriver Plumbers' Putty or Caulking 7 1 Roughing-in Dimensions BIDET OUTLINE IS SYMBOLIC FINISHED FLOOR FINISHED WALL 1-1/4 O.D. TAILPIECE DOUCHE SPRAY 2-1/8 DIA. ADJ. 1-1/4 TO 2-1/4 3-7/8 5-1/2 1-3/8 DIA. 7/8 DIA. 1-1/4 MAX. 1-3/16 DIA. 2-1/4 (C) (H) DIA. 4-1/4 FOR GROUND JOINT CONNECTION OR 1/2 " O.D. SLIP (INLETS) REAR VIEW WITH WALL REMOVED TRANSFER VALVE (FOR FLUSHING RIM OR SPRAY) 8 TO 12 Speed Connect Drain* • Fewer parts, installs in less time • Never needs adjustment • Guaranteed to seal properly the first time, every time. M968677 Rev. 1.1 2 POP-UP DRAIN Tighten TAILPIECE (4) on DRAIN BODY before installing DRAIN BODY. Fig. B. DRAIN BODY 7 3 5 4 TIGHTEN LOCKNUT 1 REMOVE FLANGE Thread FLANGE (1) counter-clockwise and remove FLANGE (1) and FOAM GASKET (2) from drain body. Fig. A. Thread LOCKNUT (3) clock-wise to bottom of drain body. Push GASKET (4) down against LOCKNUT (3). Fig. B. Remove CLEAR PLASTIC COVER (1). Remove CARDBOARD SPACER (2) from under DRAIN POP-UP (3). 2 2 3 3 1 1 Tighten LOCKNUT (1) firmly with Adjustable Wrench or Channel Locks. 2 INSTALL DRAIN FROM BELOW FIXTURE 6 From under side of BIDET install DRAIN BODY (1) up through drain outlet. Note: No plumber’s putty or caulk is required. The CABLE ATTACHMENT POINT (2) must face towards the rear of the BIDET. DRAIN OUTLET Install FOAM GASKET (3) and FLANGE (4) onto drain body from above BIDET and tighten FLANGE (4) firmly. 1 4 3 4 Fig. A. Fig. B. Fig. A. Fig. B. 7 FLANGE GASKET Check DRAIN FLANGE in BIDET to ensure that WHITE FOAM GASKET (1) is fully compressed and not visible. Fig. A. DRAIN FLANGE 1WHITE FOAM GASKET NOT VISIBLE Insert LIFT ROD GUIDE (1) and CABLE CONNECTOR (2) through rear hole, making sure SEAL WASHER (3) is properly seated. Fig. B. From below slip slot in MOUNTING NUT (4) over CABLE (5). Thread NUT (4) onto lift rod guide shank to secure ROD GUIDE (1) to bidet. Hand tighten only. Fig. B. 1 2 4 3 ILLUSTRATION SHOWN LESS VALVES SLOTTED MOUNTING NUT POP-UP ROD ASSEMBLY Fig. A. Fig. B. Connect HOT water supply to inlet of left SHANK and COLD water supply to right SHANK using sealant, appropriate connectors, and COUPLING NUTS. Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to waste outlet. 10 Connect water supply to VALVE BODIES (7,7a) with 1/2" IPS FLEXIBLE SUPPLIES (8) or 3/8" O.D. BULL-NOSE RISERS (9). Use adjustable wrench to tighten connections. Do not over tighten. Be careful not to kink copper supply when bending. Use tubing cutter to cut to proper length. TEE AND HOSE CONNECTION NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS NOT INCLUDED AND MUST BE PURCHASED SEPARATELY. HOT COLD FLEXIBLE SUPPLIES 1 1/2" PIPE THREAD 3/8 COMPRESSION CONNECTION 2 POP-UP KNOB (1) must be fully down. Fig. A. Thread CABLE CONNECTOR (1) clockwise onto DRAIN BODY CONNECTION (2) and hand tighten. Fig. B. Your new POP-UP DRAIN installation is now complete. Fig. C. Note: Tailpeice on pop-up drain is 1-1/4” O.D. Fig. C. Fig. B. ATTACH CABLE CONNECTOR 8 Operate LIFT KNOB (1) to verify that STOPPER (2) opens and closes. Note: If STOPPER (2) does not open and close properly then refer to the “troubleshooting section” of these instructions. CHECK OPERATION OF POP-UP INSTALL DIVERTER KNOB 9 Fig. C. 1-1/4” O.D. M968677 Rev. 1.1 DOWN Fig. A. 1 1 5 3 1 2 2 WATER SUPPLY CONNECTION Insert SEAL (1) into ADAPTER (2) ...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias