Facilidade de uso


Push DIVERTER (9) back into MANIFOLD (10). Reverse procedure to reinstall SPOUT, CARTRIDGE and HANDLE. Remove PLUG BUTTON (2), loosen HANDLE SCREW (1) and remove HANDLE (3). Remove ESCUTCHEON CAP (4). Unscrew the three CARTRIDGE SCREWS (5). Clean MANIFOLD (10), CARTRIDGE (6) ports and SEALS (13). Clean inlets of CARTRIDGE (6) and MANIFOLD (10). Reassemble CARTRIDGE (6), alternately tightening SCREWS (5). Replace CAP (4) and HANDLE (3). Check flow. SERVICE 5Clogged CARTRIDGE outlets or inlets may cause reduced flow. To clean, first turn off water supply then: Reduced flow. If the flow gradually reduces over a number of months, the AERATOR (12) may have collected debris. To clean, remove AERATOR (12) and rinse with water and remove any debris. Turn on faucet to wash any debris out of the faucet. Thread AERATOR (12) back into spout. Operate faucet. 631 2 11 8 10 7 4 5 6 13 12 9 SPOUT HUB DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH. DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE. CARE INSTRUCTIONS: ...