Log:
Sort : Nome ↑   Downloads   Avaliação   Tamanho ↑  
Downloads : 4   Arquivo Tamanho: 58 kb   Fabricante : Bradley Smoker  
Categoria : Canalização
@name

File these instructions with the owner or maintenance department. P.O. Box 309, Menomonee Falls, WI 53052-0309 215-1384Rev.A;EN01-819 TEL. 1-800-BRADLEY FAX (262) 251-5817 Page1of4 Express® LavatorySystemMG-SeriesExtension MG-EXT InstallationInstructions Pre-Installation Information Check Contents Separate all parts from the packaging and check each part with the drawing below. Make sure all parts are accounted for before discarding any packaging material. If any parts are missing, do not attemp

Downloads : 0   Arquivo Tamanho: 562 kb   Fabricante : Bradley Smoker  
Categoria : Canalização
@name

Terreon® is a unique, cast solid surface material. Aggregate flow and distribution as well as shades of color can vary from product to product creating natural characteristics. Brand Names: Use of brand names is intended only to indicate a type of cleaner. This does not constitute an endorsement, nor does the omission of any brand name cleaner imply inadequacy. Many products named are regional in distribution, and can be found in local supermarkets, department and hardware stores, or through you

Downloads : 0   Arquivo Tamanho: 2 mb   Fabricante : Bradley Smoker  
Categoria : Canalização
@name

1 Enable “Manual Setting” Mode > See “Enabling Manual Setting Mode” section 2 Fully cover sensor with hand. Water fl ow stops after 5 seconds - Continue to hold on for another four (4) additional water pulses. 3 Remove hand. Result: Scrub Mode is now activated for 180 seconds. F - Sensor Range Adjustment The detection distance of the sensor can be adjusted between approximately 4 - 11 inches from the infrared window. 1 Enable “Manual Setting” Mode > See “Enabling Manual Setting Mode” section 2 R

Downloads : 2   Arquivo Tamanho: 562 kb   Fabricante : Bradley Smoker  
Categoria : Canalização
@name

O.D. washers to mount main frame and bowl to wall (minimum pull-out rating of 1,000 lbs.) • (2) #10 wall anchors (for optional mixing valve/bracket mounting) • 1/2" NPT hot/cold or tempered supply piping • 1-1/2" NPT drain piping • OPTIONAL: 110 volt GFCI protected electrical outlet for 100–120 VAC plug-in transformer (for Bradley Faucets) • OPTIONAL: 240/208 or 277 volts for electric tankless water heater Installation FL-1H, FL-1L Cleaning and Maintenance for Terreon® Material Description: Terr

Downloads : 8   Arquivo Tamanho: 773 kb   Fabricante : Bradley Smoker  
Categoria : Canalização
@name

For more than three washfountains, pipe sizes should be increased proportionately. -Supplies from below or through wall - Vented through ceiling off trap inside pedestal Type O Drain -Supplies from above - Vented from below or through wall off drain (mm) Figure 2d NOTE: Supply lines for one to two washfountains should be 1”; for three washfountains, 1-1/4”. For more than three washfountains, pipe sizes should be increased proportionately. Bradley Corporation • 215-1470 Rev. H; EN 06-915 2/8/07 T

Downloads : 5   Arquivo Tamanho: 246 kb   Fabricante : Bradley Smoker  
Categoria : Canalização
@name

Welded construction with burr-free edges. FLANGE: 22 gauge stainless steel with exposed surfaces in architectural satin finish. One-piece seamless construction, 1" wide with W" return. DOOR: 18 gauge stainless steel with full-length piano hinge and tumbler lock keyed like other Bradley units. PUSH FLAP DOOR: 22 gauge stainless steel with exposed surfaces in architectural satin finish. Self-closing, with heavy-duty stainless steel piano hinge. WASTE RECEPTACLE: leakproof molded plastic. 1.0 g

Downloads : 0   Arquivo Tamanho: 2 mb   Fabricante : Bradley Smoker  
Categoria : Canalização
@name

. . . . . . . . . . . . . . . . . . . . . . . . . .9 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . 10 Care and Maintenance . . . . . . . . . . . . . . . . . 12 Multi-Faucet Transformer Wiring . . . . . . . . . 14 IMPORTANT! Read this entire installation manual to ensure proper installation. When finished with the installation, file this manual with the owner or maintenance department. Compliance and conformity to local codes and ordinances is the responsibility of the installer. Se

Downloads : 4   Arquivo Tamanho: 262 kb   Fabricante : Bradley Smoker  
Categoria : Canalização
@name

• Graffiti/Vandalism: If vandals create markings on the panel, Bradley recommends using Motsenbocker’s LIFT OFF® to remove ink and spray paint. Remover #3 is for ink and markers, and Remover #4 is for spray paint. Motsenbocker’s LIFT OFF® can be ordered through Sanitary Maintenance Service Inc. (call 1-800-451-5523 x 425 or visit for ordering information). After cleaning with LIFT OFF®, give the panel a final thorough cleaning with a liquid tub and tile cleaner to remove soil and maintain the gl

Downloads : 3   Arquivo Tamanho: 241 kb   Fabricante : Bradley Smoker  
Categoria : Canalização
@name

Wall anchors used must have a minimum pull-out rating of 1,000lbs. Product warranties may be foundunder "Product Information" on our web site at Installation Instructions OBSOLETE SS-3/AST/WH97TAS Express® LavatorySystem SS-Series *Complies with Texas Accessibility Standards (TAS) for Juvenile Height applications. Table of Contents Pre-Installation Information . . . . . . . . . . . . . . . .2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4 Installation Instructions . . . . .

Downloads : 7   Arquivo Tamanho: 228 kb   Fabricante : Bradley Smoker  
Categoria : Canalização
@name

This will continue for 8 minutes and then stop. Proceed to Faucet Operation, page 6. Bradley Corporation •215-1559 Rev. A; EN 04-216A 9/23/04 Aerada 1000 Series Gooseneck Faucet Installation Instructions Faucet Operation Operating Modes • Normal Motion Detecting Mode: water flows within 1/4 second after activating sensor (i.e., putting hands in front of collar) and continues to stay on as long as motion is detected. Maximum time is 45 seconds (factory default setting). • Scrub Mode: water contin