Log:
Assessments - 4, GPA: 4.8 ( )

Instruções de Operação Altinex, Modelo MT104-107

Fabricante : Altinex
Arquivo Tamanho: 745.06 kb
Arquivo Nome : aaa861a1-f56f-4f5b-9654-9ca1544b2065.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


7. […F] – Feedback After processing a command, an OK or ER will be returned as feedback if "F" is included at the end of a command string. 8. […P] – Path This command will set the path for the output, but it is not active until the switch command, [SW], is executed. Commands ending in "P" are not executed immediately. The path for outputs on multiple cards or the same card can be preloaded. See examples in ON and OFF commands. 9. [SW] – Switch The switch command immediately connects inputs and outputs, which were previously set with the path command on this card and all other cards in the Multi-Tasker™ Enclosure. Example: [ON1C6U3P] [ON3C7U3P] [SW] The above example turns ON input 1 of card 6 of unit 3 at the same time as input 3 of card 7 of unit 3. 10. [HELP] This command displays information available for the Multi-Tasker interface commands. Command Format: [HELPCnUi] Cn = card ID number (n = # from 1 to max slots) Ui = Unit ID (i = # from 0 to 9) Example: In order to view the RS-232 commands available for the MT104-107 card in slot 2 of unit 3, send the command [HELPC2U3]. The commands along with a brief description will be displayed in the Terminal Window. 11. [WR] This command groups multiple cards in the Enclosure. Each unit contains a maximum of nine groups. Command Format: [WRCn…GkUi] Cn = card ID (n = slot # from 1 to max slots) Gk = group number (k = # from 1-9) 10 MULTI-TASKER Ui = unit number (i = # from 0-9) Example: To group cards #1, 2, and 3 as group 5 of unit #1, send the command [WRC1C2C3G5U1]. After executing this command, cards 1, 2 and 3 will be grouped together as group 5 of unit 1. 12. [CLR] This command clears the members for a single group or for all nine groups. Command Format: [CLRGkUi] Gk = group number (k = # from 1-9) Ui = unit number (i = # from 0-9) Example: 1) To clear group #1, send the [CLRG1U1] command. This command clears the members for the specified group only. 2) To clear all groups of unit 1, send the [CLRG[U1] command. 13. [G] This command is used to request group data. With the command, the user can identify which input or output of a particular group is on. Command Format: [GkUi] Gk = group number (k = # from 1-9) Ui = unit number (i = # from 0-9) Example: In unit ID 0, if group 1 has DA Cards with outputs 1 and 2 on, while group 2 has SW Cards with input 2 on: [G1]: will return feedback as ON12 G1U0. [G2]: will return feedback as ON2 G2U0. 14. [RD] This command displays the members in each group. Command Format: [RDGkUi] Gk = Group number (k = # from 1-9) Ui = Unit ID (i = # from 0-9) Example: The cards in slots 1, 2 and 19 are part of group 5 in unit 1. Read the member data for group 5 of unit 1, by sending the command [RDG5U1]. The system will return feedback as follows: C1C2C19 G5U1 C1 = Card in Slot 1 C2 = Card in Slot 2 C19 = Card in slot 19 G5 = Group 5 U1 = Unit ID 1 15. [CLM] This command removes the members in a group and leaves the group empty. Command Format: [CLMGkUi] Gk = Group number (k = # from 1-9) Ui = Unit ID (i = # from 0-9) Example: Group 5 of Unit 1 contains the cards in slots 1, 2 and 19. Read the member data for group 5 of unit 1, by sending the command [RDG5U1]: C1C2C19 G5U1. Now, clear group 5 by sending the command [CLMG5U1]. Reread the member data as above and note the following feedback: NONE G5U1 7.3 SUMMARY OF COMMANDS 1) [VER] Receives software version 2) [Ci] Receives status of the card 3) [CiS] Saves card configuration 4) [ON] Turns on one or more outputs for a single card or a group of cards 5) [OFF] Turns off one or more outputs for a single card or a group of cards 6) […S] Save the command configuration 7) […F] Provides feedback upon sending 11 MULTI-TASKER 8) […P] Sets the path, preload for [SW] 9) [SW] Switch preloaded output buffer 10) [HELP] Display available commands 11) [WR] Groups multiple cards 12) [CLR] Clears members of a single group or all groups 13) [G] Requests group data 14) [RD] Displays group members 15) [CLM] Remove members from a group TROUBLESHOOTING GUIDE 8 We have carefully tested and have found no problems in the supplied MT104-107; however, we would like to offer suggestions for the following: 8.1 LED IS NOT LIT Cause 1 Card cage is not plugged in. Solution: Plug card cage in. If the LED lights, the problem is solved. If the LED is still not ON, see Cause 2. Cause 2: Card is not plugged in all the way. Solution: Push the card in all the way. If the LED is still not ON, see Cause 3. Cause 3: Card cage slot has a problem. Solution 1 Test the card in other slots of the card cage. If the slot was damaged, the card may work in other slots. If other slots work and the LED lights, the problem is the card cage slot. The card cage may require service. Call ALTINEX at (714) 990-2300. If the other slots do not work and the LED is still not lit, see Solution 2. Solution 2 Take any other known good card with an LED and install it in the questionable slot. If the LED on the good card comes ON, then the original card ...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias