Log:
Assessments - 4, GPA: 3.8 ( )

Instruções de Operação Agilent Technologies, Modelo L4445A

Fabricante : Agilent Technologies
Arquivo Tamanho: 297.89 kb
Arquivo Nome : 5989-4828EN.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


• Qty 1 Y1150A Distribution board to control qty 8 N1810UL switches. Notice that each Y1152A can also drive two N181x switches. Therefore if you only needed to drive 4 N1810 switches, then you could have controlled those switches via the Y1152A distribution boards already selected. Here is the final recommended configuration: • (qty 2) 87206B DC-20 GHz SP6T Switches • (qty 8) N1810UL DC-20 GHz SPDT Switches • (qty 1) L4445A Switch/Attenuator Driver (when ordering the L4445A, the 34945EXT is automatically added for controlling switches) • (qty 2) Y1152A Distribution Boards • (qty1) Y1150A Distribution Board • Either build own cables using off-the-shelf parts, or order qty 1 Y1159A 16-to-16 pin connect kit (supplies for 2 cables) and qty 2 Y1157A 9-to-10 pin cable kit (supplies for 4 cables). We recommend that the switch be ordered with options for 24 V coils, position indicators, and socket connectors. Since 24 V latching relays are specified, there is no need for an external power supply. The L4445A instrument can provide power for a single 34945EXT. Easy-to-build ribbon cables can be built to interface each of the switches to the Y1150A and Y1152A distribution boards. See the Application note: Configuring an RF/ Microwave Switch System (5989-2272EN) for additional configuration details. 8 Ordering information (Continued) L4445A Microwave Switch/ Attenuator driver Includes User’s guide on CD, test report, power cord, and Quick Start package Option -GPIB Adds GPIB interface Option 0B0 Deletes printed manual set, full documentation included on CD ROM Option ABA English printed manual set L4445A Accessories Distribution boards are required for control of external switches. One 34945EXT external driver required for each 64 coils – holds 4 distribution boards per 34945EXT extender Y1150A 34945EXT distribution board for 8 N181x SPDT switches Y1151A 34945EXT distribution board for two 87104x/106x multiport or 87406B matrix switches Y1152A 34945EXT distribution board for one 87204x/206x or 87606B switch and two N181x switches Y1153A 34945EXT distribution board for two 84904/5/6/7/8 or 8494/5/6 step attenuators Y1154A 34945EXT distribution board for two 87222 transfer switches and six N181x SPDT switches Y1155A 34945A distribution board w/ generic screw terminals for driving 16 switch coils Cable kits for connecting switches to distribution boards: Y1157A 9-to-10 pin cable kit for Y1150A, Y1152A, Y1154A - supplies to build 4 cables Y1158A 10-to-10/10-to-14 pin cable kit for Y1153A, Y1154A - supplies to build 2 cables Y1159A 16-to-16 pin cable kit for Y1150A/51A/52A/53A/54A/55Asupplies to build 2 cables Other accessories Y1160A Rack mount kit for L4400 series instruments- racks 2 instruments side-by-side with sliding tray For additional information please visit: 9 Agilent Email Updates Get the latest information on the products and applications you select. Agilent Direct Quickly choose and use your test equipment solutions with confidence. Agilent Open Agilent Open simplifies the process of connecting and programming test systems to help engineers design, validate and manufacture electronic products. Agilent offers open connectivity for a broad range of system-ready instruments, open industry software, PC-standard I/O and global support, which are combined to more easily integrate test system development. LXI is the LAN-based successor to GPIB, providing faster, more efficient connectivity. Agilent is a founding member of the LXI consortium. Related Agilent literature Data Sheets 5988-6302EN Agilent VEE Pro 5989-1441EN Agilent W1140A-TKT T&M Toolkit 2.0 with Test Automation 5989-1439EN Agilent E2094N I/O Libraries Suite 14 5989-2272EN Configuring an RF/Microwave Switch System Remove all doubt Our repair and calibration services will get your equipment back to you, performing like new, when prom- ised. You will get full value out of your Agilent equipment through- out its lifetime. Your equipment will be serviced by Agilent-trained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. You will always have the utmost confidence in your measurements. Agilent offers a wide range of ad- ditional expert test and measure- ment services for your equipment, including initial start-up assistance onsite education and training, as well as design, system integration, and project management. For more information on repair and calibration services, go to: For more information on Agilent Technologies’ products, applications or services, please contact your local Agilent office. The complete list is available at: Americas Canada (877) 894-4414 Latin America 305 269 7500 United States (800) 829-4444 Asia Pacific Australia 1 800 629 485 China 800 810 01...

Este manual também é adequado para os modelos :
Equipamento de rede - L4445A (297.89 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias