Log:
Assessments - 2, GPA: 4 ( )

Instruções de Operação Altinex, Modelo Multi Tasker MT107-306

Fabricante : Altinex
Arquivo Tamanho: 3.08 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Make sure that cable connector is secured in the socket of the input card. Step 3. Carefully, slide the MT107-301/305/306 into slot of the Multi-Tasker™ Enclosure. Step 4. Secure each card by tightening the retainer screws at the top and bottom of each card. 7.1 RS-232 CONTROL The MT107-301/305/306 has many advanced remote control capabilities when used in the Multi-Tasker™ Enclosure as part of an MT107-100 Matrix Switcher. These capabilities are accessible through standard RS-232 communication. The actual controlling can be accomplished through a computer control system or any other device capable of sending RS-232 commands. 7.2 DESCRIPTION OF COMMANDS Please, see the MT107-100 User's Guide for a full listing of commands available for the MT107 301/305/306 as part of a Multi-Tasker™ Matrix Switcher. TROUBLESHOOTING GUIDE 8 We have carefully tested and have found no problems in the supplied MT107-301/305/306. However, we would like to offer suggestions for the following: 8.1 BAD SIGNAL Cause 1: The display is connected to the wrong card. Solution: Make sure the video signals are coming from the video card (-305) and sync signals are coming from the sync card (-306). If the signal is still bad, see Cause 2. Cause 2: The switch settings are wrong. Solution: If the output card is an MT107-301, make sure the Video/Sync switch settings are in the correct position for the signal type on each channel. If the signal is still bad, call Altinex at (714) 990-2300. 9 MULTI-TASKER™ 8.2 NO DISPLAY Cause 1: The source has a problem. Solution: Check the source and make sure that there is a signal present and all source connections are correct. If the source is working and there is still no display, see Cause 2. Cause 2: The output signal is not detected. Solution 1: In MTSetup™, or other control software, send the [SDO] command. This command is detailed in the MT107-100's User Guide. Verify a signal is detected for the output number in question. If a signal is not detected, see Solution 2. Solution 2: Verify the MT107-301/305/306 is connected to the MT107-100 and that the cable is in good condition. If a signal is detected, see Cause 3. If there is no signal detected, please, call Altinex at (714) 990-2300. Cause 3: The path is not selected. Solution: Make sure the input to output path is correctly selected. For example, Input 1 is connected to Output 17 in the matrix engine. Physically, the source signal is connected to Input 1 and the display cable is connected to Output 17. See RS-232 accessible commands in Section 7 of the MT100-107's User Guide for command details. If no display is present, see Cause 4. Cause 4: Cable connections are incorrect. Solution: Make sure that cables are properly connected. Also, make sure that the continuity and wiring are good. If there is still no display present, see Cause 5. Cause 5: The display has a problem. Solution: Make sure the display has power and is turned ON. If there is still no display, please (714) 990-2300. call Altinex at ALTINEX POLICY 9 9.1 LIMITED WARRANTY/RETURN POLICY Please see the Altinex website at for details on warranty and return policy. 9.2 CONTACT INFORMATION ALTINEX, INC 592 Apollo street Brea, CA 92821 USA TEL: 714-990-2300 TOLL FREE: 1-800-ALTINEX WEB: E-MAIL: solutions@altinex.com 10 ...

Este manual também é adequado para os modelos :
Equipamento de rede - Multi Tasker MT107-301 (3.08 mb)
Equipamento de rede - Multi Tasker MT107-305 (3.08 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias