Log:
Assessments - 3, GPA: 4.7 ( )

Instruções de Operação Grizzly, Modelo G0719

Fabricante : Grizzly
Arquivo Tamanho: 2.55 mb
Arquivo Nome : g0719_m.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Circuit information A power supply circuit includes all electrical equipment between the breaker box or fuse panel in the building and the machine. The power supply circuit used for this machine must be sized to safely handle the full-load current drawn from the machine for an extended period of time. (If this machine is connected to a circuit protected by fuses, use a time delay fuse marked D.) Electrocution, fire, or equipment damage may occur if machine is not correctly grounded and connected to the power supply. full-Load Current rating The full-load current rating is the amperage a machine draws at 100% of the rated output power. On machines with multiple motors, this is the amperage drawn by the largest motor or sum of all motors and electrical devices that might operate at one time during normal operations. full-Load Current rating at 220v ..... 12 amps The full-load current is not the maximum amount of amps that the machine will draw. If the machine is overloaded, it will draw additional amps beyond the full-load rating. If the machine is overloaded for a sufficient length of time, damage, overheating, or fire may result— especially if connected to an undersized circuit. To reduce the risk of these hazards, avoid overloading the machine during operation and make sure it is connected to a power supply circuit that meets the requirements in the following section. For your own safety and protection of property, consult a qualified electrician if you are unsure about wiring practices or electrical codes in your area. Note: The circuit requirements listed in this manual apply to a dedicated circuit—where only one machine will be running at a time. If this machine will be connected to a shared circuit where multiple machines will be running at the same time, consult a qualified electrician to ensure that the circuit is properly sized for safe operation. Circuit requirements This machine is prewired to operate on a 220V power supply circuit that has a verified ground and meets the following requirements: nominal voltage .............................. 220v/240v Cycle..........................................................60 hz phase........................................... single-phase Circuit rating...................................... 15 amps plug/receptacle ............................. nEMa 6-15 -9 model g0719 (mfg. since 10/10) Grounding requirements This machine MUST be grounded. In the event of certain malfunctions or breakdowns, grounding reduces the risk of electric shock by providing a path of least resistance for electric current. For 220V operation: This machine is equipped with a power cord that has an equipment-grounding wire and a grounding plug (see following figure). The plug must only be inserted into a matching receptacle (outlet) that is properly installed and grounded in accordance with all local codes and ordinances. GROUNDED 6-15 RECEPTACLE Current Carrying Prongs 6-15 PLUG Grounding Prong figure 2. typical 6-15 plug and receptacle. Improper connection of the equipment-grounding wire can result in a risk of electric shock. The wire with green insulation (with or without yellow stripes) is the equipment-grounding wire. If repair or replacement of the power cord or plug is necessary, do not connect the equipment-grounding wire to a live (current carrying) terminal. Check with a qualified electrician or service personnel if you do not understand these grounding requirements, or if you are in doubt about whether the tool is properly grounded. If you ever notice that a cord or plug is damaged or worn, disconnect it from power, and immediately replace it with a new one. Serious injury could occur if you connect the machine to power before completing the setup process. DO NOT connect to power until instructed later in this manual. Extension Cords We do not recommend using an extension cord with this machine. If you must use an extension cord, only use it if absolutely necessary and only on a temporary basis. Extension cords cause voltage drop, which may damage electrical components and shorten motor life. Voltage drop increases as the extension cord size gets longer and the gauge size gets smaller (higher gauge numbers indicate smaller sizes). Any extension cord used with this machine must contain a ground wire, match the required plug and receptacle, and meet the following requirements: Minimum Gauge size ...........................14 aWG Maximum Length (shorter is Better).......50 ft. -10 model g0719 (mfg. since 10/10) Model G0719 (Mfg. Since 10/10) -11- Wear safety glasses during the entire setup process! This machine presents serious injury hazards to untrained users. Read through this entire manual to become familiar with the controls and operations before starting the machine! SECTI ON 3: SETUP The following are needed to complete the setup process, but are not included with your machine. Description Qty • S afety Glasses............................................. 1 • Cleaner/De...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias