Log:
Assessments - 2, GPA: 5 ( )

Instruções de Operação FEIN Power Tools, Modelo FMM 250Q

Fabricante : FEIN Power Tools
Arquivo Tamanho: 2.59 mb
Arquivo Nome :
Língua de Ensino: enesfr
Ir para baixar



Facilidade de uso


value on the type plate of the power tool is prohibited. Symbols. Symbol Term, meaning Explanation . Action Action to be taken by the user Do not touch the saw blade. Danger of sharp application tools moving back and forth. General mandatory sign Follow the instructions in the adjacent text! Read documentation Be absolutely sure to read the enclosed documentation such as the Instruction Manual and the General Safety Instructions. Use eye-protection Use eye-protection during operation. Wear ear protection Use ear protection during operation. Use dust mask Use a dust mask during operation. Use protective gloves Use protective gloves during operation. It is forbidden to dispose of the product in the unsorted household waste. Worn out power tools and other electro- technical and electrical products should be sorted separately for environment-friendly recycling. This symbol confirms the certification of this product for the USA and Canada. 8 3 41 01 091 21 0.book Seite 9 Dienstag, 24. Juli 2007 3:32 15 3 41 01 091 21 0.book Seite 9 Dienstag, 24. Juli 2007 3:32 15 MULTIMASTER FMM 250 / MULTIMASTER FMM 250 Q EN Symbol DANGER Term, meaning WARNING Explanation DANGER This sign warns of a directly imminent, dangerous situation. A false reaction can cause a severe or fatal injury. WARNING This sign indicates a possible dangerous situation that could cause severe or fatal injury. CAUTION CAUTION This sign warns of a possible dangerous situation that could cause injury. Protective class II Product with double or reinforced insulation mm Millimeter Unit of measure for length, width, height or depth kg Kilogram Unit of measure for the mass V Volt Unit of measure for the electric voltage A Ampere Unit of measure for the electric current intensity W Watt Unit of measure for the output min per minute Unit of measure for number of revolutions, strokes, impacts or oscillations per minute ° Degree Unit of measure for the angle width ~ or a. c. Current type Alternating current 1 ~ Power supply type Alternating current single-phase No-load speed Revolution speed at no-load 1/min no per minute Unit of measure for number of revolutions, strokes, impacts or oscillations per minute O Diameter Diameter of a round part Technical description and specifications. WARNING Before mounting or replacing application tools or accessories, pull the power plug. This preventive safety measure rules out the danger of injuries through accidental starting of the power tool. 9 10 EN MULTIMASTER FMM 250 / MULTIMASTER FMM 250 Q Only part of the accessories described or shown in this instruction manual will be included with your power tool. Type MULTIMASTER FMM 250 MULTIMASTER FMM 250 Q Reference number 7 229 36 7 229 37 Rated voltage 120 V/60 Hz 120 V/60 Hz Power Input 250 W 250 W Output 140 W 140 W Current 2.3 A 2.3 A Power supply type 1 ~ 1 ~ Oscillating frequency 11 000–20 000/min 11 000–20 000/min Weight according to EPTA-Procedure 01/2003 1.2 kg 1.4 kg Class of protection II II Oscillating angle 1.6 ° 1.6 ° Quick-clamping lever On/Off switch Dial control for adjustment of oscillating frequency Depth stop Suction device Multimaster FMM 250 Q Fig. 1 3 41 01 091 21 0.book Seite 10 Dienstag, 24. Juli 2007 3:32 15 MULTIMASTER FMM 250 / MULTIMASTER FMM 250 Q 11 EN Assembly instructions. Mounting the suction device (Figure 2). Before mounting or replacing application tools or accessories, pull the power plug. This preventive safety measure rules out the danger of injuries through accidental starting of the power tool. .Mount the suction device step by step as shown in the figures. .For connection with a FEIN Dustex or a vacuum cleaner, various hose adapters are available as an accessory. .To remove the suction device again, push the clamp at the mark to the rear (.). WARNING Suction device . . . . . . . . Fig. 2 3 41 01 091 21 0.book Seite 11 Dienstag, 24. Juli 2007 3:32 15 3 41 01 091 21 0.book Seite 12 Dienstag, 24. Juli 2007 3:32 15 EN MULTIMASTER FMM 250 / MULTIMASTER FMM 250 Q Changing the tool. The application tool can be fastened offset at convenient working positions at 45° steps (or at 30° steps for the triangle-shaped sanding pad). MULTIMASTER FMM 250 Q (Figure 3). WARNING Before mounting or replacing application tools or accessories, pull the power plug. This preventive safety measure rules out the danger of injuries through accidental starting of the power tool. CAUTION For all work or when chang ing application tools, always wear protective gloves. Danger of injury from the sharp edges of the application tools. Application tools can become very hot while working. Danger of burns! . Loosen the quick-clamping lever and swivel it to the stop. . Pull out the fastening element. 180° Fastening element Tool holder Quick-clamping lever Fig. 3 . Clean the tool holder, the application tool and the fastening element. . Place the application tool exactly onto the star-shaped tool holder. Pay attention that the application tool has a flush fit. . Insert t...

Este manual também é adequado para os modelos :
Máquinas e acabar - FMM 250 (2.59 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias