|
Facilidade de uso
If it does not fit, use a cord with a correct connection. If the cord does not fit into the power supply outlet, contact a qualified electrician to install the proper outlet. DO NOT change the plug on the extension cord or unit in any way. WARNING: 6. Secure the extension cord to motor housing as shown (Fig. 13) Fig. 13 STARTING AND STOPPING THE BLOWER /VAC This unit is equipped with an OFF/LOW/HIGH switch . For low speed operation, slide the switch up to the first click (A). To select high speed, slide the switch up to the second click (B). To turn the unit off, slide the switch all the way down (C). (Fig. 14) (C) (A) (B) Fig. 14 To avoid serious personal injury, wear goggles or safety glasses at all times when operating this unit. Wear a face mask or dust mask in dusty locations. WARNING: OPERATING AS A BLOWER Hold the blower as shown in Figs. 15 and sweep from side to side with the nozzle several inches above the ground or floor. Slowly advance, keeping the accumulated pile of debris in front of you. Most dry blowing operations are better suited to low speed than high. Of course, you may choose to use either and you'll probably find the high speed better for moving heavier items like large debris or gravel. 1. Use the blower for trees, shrubs, flower beds and hard-to-clean areas . 2. Use the blower around buildings and for other normal cleaning. 3. Use the blower for walls, overhangs and screens. (Fig. 15) Fig. 15 9 OPERATING INSTRUCTIONS MAINTENANCE INSTRUCTIONS OPERATING INSTRUCTIONS MAINTENANCE INSTRUCTIONS OPERATING AS A VACUUM To avoid serious personal injury, wear goggles or safety glasses at all times when operating this unit. Wear a face mask or dust mask in dusty locations. WARNING: Turn off and unplug the unit before opening vacuum door or installing or removing vacuum bag to avoid personal injury from the impeller. WARNING: SHOULDER STRAP ADJUSTMENTS 1. With the unit turned off, hold the unit in your left hand in an upright position. Support the lower vacuum tube on the ground. (Fig. 16) 2. Place the vacuum bag strap over your head and onto your left shoulder. 3. Extend your right arm toward the rear of the vacuum bag. Adjust the vacuum bag strap until the vacuum bag/shoulder strap seam lies between your thumb and index finger. 4. Mark sure the vacuum bag strap is adjusted to allow a free flow of air from the vacuum bag elbow tube (Fig. 18). If the bag is kinked, the tool will not operate properly. To avoid serious personal injury, do not wear loose fitting clothing or articles such as scarves, strings, chains, ties, etc., because they could gat drawn into the air intake. Long hair must be pulled back and secured off shoulders and neck. WARNING: Fig. 16 Hold the vacuum, tilting the suction tube slightly, and use a sweeping action to collect light debris (Fig. 18). The debris will flow into the vacuum bag.Things such as small leaves and small twigs will be mulched as they pass through the fan housing, allowing the vacuum bag to hold a lot of debris. When the bag is full, suction will noticeably decrease. Turn off and unplug the unit before you unzip the bag. Unzip the bag and empty the contents before continuing. To avoid serious personal injury, never unzip the vacuum bag without first turning off and unplugging the unit. WARNING: As a vacuum, the unit is designed to pick up dry material such as leaves, grass, small twigs and bits of paper. To avoid seri- ous personal injury, do not attempt to vac- uum wet debris and/or standing water as this may result in damage to the Blower/Vacuum and possible electric shock. To avoid severe damage to the impeller, do not vacuum metal, broken glass, etc. WARNING: When the upper and lower vacuum tubes are removed, make sure the vacuum door is snapped closed before plugging in the unit, to avoid injury form the impeller. WARNING: MAINTENANCE SERVICING DOUBLE-INSULATED APPLIANCE In this double-insulated appliance, two systems of insulation are provided instead of grounding. No grounding means is provided on a double-insulated appliance, nor should a means for grounding be added to the appliance. There are no serviceable parts inside. A double- insulated appliance is marked with the words, “DOUBLE INSULATION” or “DOUBLE INSULATED”. The symbol (square within a square) may also be marked on the appliance. 1. Place switch in “OFF” position and unplug the power supply before the appliance is serviced, cleaned or maintenance is performed. 2. Keep air intake clean and air vents free of debris to avoid overheating the motor. 3. Clean with a damp sponge and mild soap. Do not squirt with a water hose or douse with water or other liquids. 4. If the blower vibrates abnormally, stop motor immediately. Abnormal vibration usually indicates a mechanical problem and continued operation could lead to injury or damage to the blower. 5. No lubrication is necessary as the motor is equipped with lifetime lubricated bearings. 6. If the blower does not operate, turn switch to “OFF” p...
Este manual também é adequado para os modelos :Sistemas de ventilação - TB120BV (1.25 mb)