Facilidade de uso


Tighten screws holding leveling bracket to unit on each side. 3 INSTALL DUCTWORK CAUTION -BEFORE CUTTING HOLE IN CABINET FOR DUCTWORK: Check for interference with floor joists, wall studs, electrical wiring or plumbing. 6" RD. ELBOW & DUCT- WORK 3-1/4" X 10" TO 6" RD. TRANSITION BLOWER COLLARSCREWS 1. Cut hole in cabinet as well as holes in wall or floor as necessary. 2. Mount the roof or wall cap and work back towards the cabinet, attaching all ductwork, elbows and transitions as previously planned. Tape all ductwork connections to make them secure and air tight. 3. Connect ductwork (and transition, if required) to downdraft. If necessary, LOOSEN nuts and screws that hold the blower in place, and slide blower left or right to meet ductwork. Retighten screws and nuts. Note: A 3-1/4" x 10" collar is provided for installers who prefer to rivet the ductwork to the unit. This will allow blower to be removed and replaced easily in service situations without disturbing ductwork. INSTALL ELECTRICAL WIRING 1. Mount a standard wiring box, with 3-pronged receptacle, inside the cabinet. Make sure the downdraft’s power cord can easily reach it. 2. Run appropriate power cable into cabinet and connect it to receptacle. 3. Plug the downdraft’s power cord into the outlet. WIRING DIAGRAM INSTALL COOKTOP 1. Align the cooktop with the downdraft and fasten cooktop in place. Note: Accurate alignment of cooktop and downdraft is necessary to ensure that there is no interference when air vent is raised and lowered. There should be a gap of 1/32"-1/16" between the back of the cooktop and the front of the downdraft cover. ADJUSTMENT The downdraft is factory-adjusted for proper operation. However, shipping and handling may affect the position of the activating switch. To adjust position of activating switch: WARNING: To avoid possible electrical shock, personal injury or death Disconnect electrical power. 1. If downdraft is plugged into electrical outlet, unplug it. 2. Lift air vent straight up and cock it slightly so it remains in the UP position. SCREWS SWITCH MEMBRANE SWITCH BRACKET SWITCH COVER 3. Remove switch cover from right end of air vent. 4. Loosen the 2 screws holding the switch bracket in place. Position switch bracket so that activating switch just comes in contact with underside of switch membrane. Tighten screws. 5. Replace switch cover, gently lower air vent into chimney, and plug in power cord. Re-connect electrical power and check4 operation. USE AND CARE Always turn the downdraft blower on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few minutes to clean the air after you turn the cooktop off. This will keep the whole kitchen cleaner and brighter. CONTROLS Turn the downdraft blower ON by pressing down on the activating switch. The air vent will rise. KNOB USE AND CARE - (Continued) CLEANING WARNING: Always disconnect electric power supply before cleaning unit. Use a mild detergent suitable for painted surfaces. DO NOT USE ABRASIVE CLOTH, STEEL WOOL PADS, OR SCOURING POWDERS. Vacuum blower to clean. Do not immerse blower in water. Wash the 2 aluminum grease filters in a mild detergent solution or a dishwasher. Remove them from the air vent by grasping the tab at the top of each filter. Note: The filters are different sizes. Be sure to replace them as removed, (wider one on the left), with tabs UP. SERVICING The blower can be turned ON or OFF and its speed can be adjusted with the recessed knob on the right side of the air vent. Turn the downdraft blower OFF by pressing the activating switch again. The air vent will go down and the blower will shut OFF. Note: For most convenient operation, set the blower to your favorite speed. The blower will come on to this speed whenever the activating switch is pressed and the air vent rises. WARNING: Always disconnect electric power supply before servicing unit. It may be necessary to remove the downdraft blower system from the cabinet in order to service components such as the blower motor or air vent mechanism. Disconnect power to the cooktop and remove it first. Reverse the steps under “MOUNT THE UNIT” to remove the downdraft from the cabinet. Service parts are available from your local Broan distributor or from the Broan Service Department, P.O. Box 140, Hartford, WI 53027 Phone: 1-800-637-1453. 5 SERVICE PARTS Models 2730 & 2736 Downdraft Blower Systems KEY NO. .ONYEK.ONYEK.ONKKKYE.ONYE.ONYE PART NUMBER REBMUNTRAPREBMUNTRAPREBMUNTPPPRAREBMUNTRAREBMUNTRA DESCRIPTION NOITPIRCSEDNOITPIRCSEDNOITPIRCDDDSENOITPIRCSENOITPIRCSE . ... Q. Q.Q. QTY YTYTQYQQTYTYT 1 93400038 Bushing, 7/8" 1 2 99400061 Bushing, Split Heyco, 5/8" 1 3 99400024 Bushing, Heyco, 1/2" 1 4 93470012 Roller 1 5 97011238 Switch Assembly, Up/Down 1 6 97010714 Wire Harness, Speed Control 1 7 99260491 Nut, 3/8-32 1 8 99360165 Knob 1 9 99100484 Motor Insolator 3 10 97009972 Lower Switch Bracket Assembly 1 11 97011293 Green Ground Wire 1 12 97010993 Wire Harness 1 16 98007...

Este manual também é adequado para os modelos :
Sistemas de ventilação - ECLIPSE 2730 (169.69 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias