Log:
Assessments - 5, GPA: 4.2 ( )

Instruções de Operação Little Wonder, Modelo OPTIMAX 91270-03-01

Fabricante : Little Wonder
Arquivo Tamanho: 1.29 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


- Replace caps on fuel containers and tanks securely. Sparks from static electricity can start fires or cause explosions. Flowing fuel can generate static electricity. To prevent static electricity sparks: - Keep containers electrically grounded. Do not fill containers in a vehicle or on a truck or trailer bed with a plastic liner. Fill containers on the ground away from the vehicle. - When practical, remove petrol (gasoline) powered equipment from the truck or trailer and refuel it on the ground. If equipment must be refueled on the truck or trailer, refuel from a portable container rather than a dispenser nozzle. - Keep the dispenser nozzle in contact with the rim of the fuel tank or container opening until fueling is complete. Do not use a nozzle lock-open device. - If fuel is spilled on clothing change it immediately. WARNING SAFETY SAFETY DECALS An important part of the safety system incorporated in this blower are the warning labels found on the blower. Replace labels if damaged or illegible. -Read and understand Operator manual and labels. -Wear hearing and eye protection. -Replace labels and Operator manual if lost or damaged. BEFORE STARTING: WARNING-Lea y entienda el manual del operador y las etiquetas. -Pide que alguien lea y explique el manual y las etiquetas a usted si usted no lee Ingles. -Use proteccion ocular y auditiva. -No haga funcionar sin los protectores en su lugar. -Pare el motor antes de dar servicio-La gente a mas durante la operacion. 4165977ADVERTENCIAAntes de comenzar: WARNINGThrown objects-Keep bystanders away. -Do not blow toward people or pets. -Do not blow toward items that may be damaged by flying debris. -Keep hands and feet away. -Stop engine and remove spark plug wire before servicing. -Do not operate without guards in place. Fan blades can cut/crush. DANGER4165975 SET-UP INSTRUCTIONS SET-UP INSTRUCTIONS 1. Open box. Remove upper handle and cardboard insert. 2. Lay box down with blower housing up. Use lower handle to roll unit out of the box. 3. Locate hardware package. 4. Install upper handle to lower handle with (4) 3/8-16 x 1-3/4 carriage bolts and (4) 3/8-16 flanged nylon insert nuts from the hardware package. Tighten the nuts securely but not so much as to crush the tube. (Figure 1) 5. If equipped with a Throttle Cable: Route the throttle cable in front of lower handle crossbar. Install to the left side of the upper handle with (2) 10-32 x . thread forming screws from the hardware package. (Figure 2) 6. If equipped with a Throttle Cable: Secure the throttle cables to the handle tubes with cable ties from the hardware package. Trim off excess. (Figure 3) 7. Fill the engine with oil to the level indicated on the dipstick. Fill the fuel tank with clean, fresh regular grade unleaded gasoline. FIGURE 2 FIGURE 3 FIGURE 1 CONTROLS (BLOWER SHOWN WITH HONDA GC160 ENGINE. OTHER ENGINES ARE SIMILAR.) SWITCH (A)-SUBARU ONLY (not shown) Move to the “OFF” position to stop the engine. Move to the “ON” position before starting engine. THROTTLE (B) Controls engine speed and the amount of air being blown. 91270-03-01 model has an engine mounted throttle control. CHOKE (C) Move to the “CHOKE” position to apply the choke. Move to the “RUN” position to remove the choke. FUEL SHUT OFF (D) SUBARU ONLY (not shown) Move to the “OFF” position to shut off the fuel whenever transporting the machine by trailer or truck or during storage. Move to the “ON” position before starting the engine. .LOCKING KNOB (F) Tighten the knob to lock the horizontal deflector in the desired position. Loosen to allow the deflector to be rotated with remote horizontal deflector levelr. VERTICAL DEFLECTOR (G) Rotate the deflector to direct air discharge forward or to the side. Honda Shown OPERATION / MAINTENANCE BEFORE STARTING THE ENGINE 1. Read the Operator Manual and Engine Manual. Become familiar with the controls, how each functions, and what it operates. 2. Check the engine oil level and add if necessary. 3 Fill the fuel tank with good quality, clean, unleaded regular gasoline (petrol). Use a funnel to avoid spilling. OPERATING INSTRUCTIONS Air flow can be directed to the side or front by the two-position vertical deflector. The front discharge position is used to remove debris from along walls, fences, etc. The side discharge position is used to form windrows or piles. The horizontal deflector directs air downward to “chisel” under wet, heavy leaves and litter. Air velocity is regulated by the throttle setting. To reduce windrowing or to blow over an obstacle, point deflector upward. To avoid blowing in an area, close deflector and reduce throttle setting. Slight changes in deflector position will have a big effect on air flow. Experiment until you find the best position for your needs. When clearing a yard or parking lot, a little time spent planning how to blow it off can greatly reduce the total clearing time. To stop the engine, move the throttle control to the slow position and switch the engine off. Stop...

Este manual também é adequado para os modelos :
Sistemas de ventilação - OPTIMAX 2/1/1960 (1.29 mb)
Sistemas de ventilação - OPTIMAX 2/1/1960 (1.29 mb)
Sistemas de ventilação - OPTIMAX 91270-03-01 (1.29 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias