Log:
Assessments - 3, GPA: 4 ( )

Instruções de Operação Black & Decker, Modelo BV9000

Fabricante : Black & Decker
Arquivo Tamanho: 409.21 kb
Arquivo Nome :
Língua de Ensino: enesfr
Ir para baixar



Facilidade de uso


Remove all debris and hard objects such as rocks, glass, wire, etc. that can ricochet, be thrown, or otherwise cause injury or damage during operation. As a vacuum, the tool is designed to pick up dry material such as leaves, grass, small twigs, and bits of paper. Do not vacuum stones, gravel, metal, broken glass, etc. WARNING: To reduce the risk of electrical shock; do not expose to rain, do not use on wet surfaces. Store indoors. WARNING: Turn off and unplug unit, then wait until fan stops or at least 10 seconds before removing the blower or vacuum tube assemblies. SAVE THESE INSTRUCTIONS SERVICING OF DOUBLE INSULATED APPLIANCES Your Blower/Vac is double-insulated to give you added safety. In a double insulated appliance, two systems of insulation are provided instead of grounding. No grounding means is provided on a double insulated appliance, nor should a means for grounding be added to the appliance. Servicing a double insulated appliance requires extreme care and knowledge of the system and should be done only by qualified service personnel. Replacement parts for a double insulated appliance must be identical to the parts they replace. A double insulated appliance is marked with the words double insulated or "double insulation". The symbol (square within a square) may also be marked on the appliance. SAFETY RULES AND INSTRUCTIONS: EXTENSION CORDS Double insulated tools have 2-wire cords and can be used with 2-wire or 3-wire extension cords. Only round jacketed extension cords should be used, and we recommend that they be listed by Underwriters Laboratories (U.L.) (C.S.A. in Canada). If the extension will be used outside, the cord must be suitable for outdoor use. Any cord marked as outdoor can also be used for indoor work. An extension cord must have adequate wire size (AWG or American Wire Gauge) for safety, and to prevent loss of power and overheating. The smaller the gauge number of the wire, the greater the capacity of the cable, that is 16 gauge has more capacity than 18 gauge. When using more than one extension to make up the total length, be sure each individual extension contains at least the minimum wire size. To determine the minimum wire size required, refer to the chart below. Before using an extension cord, inspect it for loose or exposed wires, damaged insulation, and defective fittings. Make any needed repairs or replace the cord if necessary. Minimum Gage for Cord Sets Volts Total Length of Cord in Feet 120V 0-25 26-50 51-100 101-150 (0-7,6m) (7,6-15,2m) (15,2-30,4m) (30,4-45,7m) 240V 0-50 51-100 101-200 201-300 (0-15,2m) (15,2-30,4m) (30,4-60,9m) (60,9-91,4m) Ampere Rating More Not more American Wire Gage Than Than 0 -6 18 16 16 14 6 -10 18 16 14 12 10 -12 16 16 14 12 12 -16 14 12 Not Recommended SAFETY WARNINGS AND INSTRUCTIONS: POLARIZED PLUG To reduce the risk of electric shock, this equipment has a polarized plug (one blade is wider than the other). This equipment must be used with a suitable polarized 2 wire or 3 wire extension cord. Polarized connections will fit together only one way. Make sure that the receptacle end of the extension cord has large and small blade slot widths. If the plug does not fit fully into the extension cord, reverse the plug. If it still does not fit, obtain a suitable extension cord. If the extension cord does not fit fully into the outlet, contact a qualified electrician to install the proper outlet. Do not change the tool plug or extension cord in any way. BEFORE OPERATING • SECURING POWER SUPPLY CORD - Secure the extension cord in the tool's built-in cord retainer as shown in Figure 12 or secure the power supply cord and a suitable extension cord as shown in Figure 13. SWITCH NOTE: The switch will not operate if the release button, shown in Figure 1, is depressed. To turn the tool ON, slide the switch forward, as shown in Figure 1. To turn tool OFF, slide switch to the rear. OPERATION USE AS A BLOWER: ALWAYS WEAR SAFETY GLASSES, WEAR A FILTER MASK IF THE OPERATION IS DUSTY. USE OF RUBBER GLOVES AND SUBSTANTIAL FOOTWEAR IS RECOMMENDED WHEN WORKING OUTDOORS. FOR HOUSEHOLD USE ONLY. • BLOWER MODE Ensure that the unit is switched OFF and is disconnected from the power supply. Assemble blow tube as shown in Figure 2. (This only needs to be done the first time you assemble the unit.) WARNING: When turning the tool off for tube installation or any other reason, wait 10 seconds for the fan to stop rotating before disassembly. Attach the blower tube assembly (The assembly includes the blower tubes, the fan chamber and the blower air speed control mechanism) to the front of the tool, as shown in Figure 3 by inserting point A into the matching recess marked point B, also shown in Figure 3. Swing the tube up to engage the lock, as shown in Figure 4. NOTE: The lock will not engage if the ON/OFF switch is in the forward (ON) position. Hold the end of the blower tube approximately 7 inches (180mm) above the ground and turn the tool ON. Using a sweeping motion, fro...

Este manual também é adequado para os modelos :
Sistemas de ventilação - 625233-01 (409.21 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias