|
Facilidade de uso
WARNING: Never put hands or other D Always see your authorized service dealer to objects into blower housing to avoid serious replace a damaged impeller. Parts that are injury from the rotating impeller. chipped, cracked, broken, or damaged in any other way can fly apart and cause seri- WARNING: Inspect the area before ous injury. Have damaged parts replaced using the unit. Remove all debris and hard ob before using attachment. jects such as rocks, glass, wire, etc., that can D Use only recommended Poulan PRO re- ricochet, be thrown, or otherwise cause injury placement parts; use of any other parts or damage during operation. may void your warranty and cause damage S Inspect attachment before each use for to your unit. worn, loose, missing, or damaged parts. Do D Never douse or squirt the attachment with not use until unit is in proper working order. S Keep outside surfaces free from oil and water or any other liquid. fuel. TRANSPORTING AND STORAGE S Never start or run engine inside a closed D Hand carry the unit with the engine room, building or other unventilated area. stopped. Breathing exhaust fumes can kill. D Allow the powerhead and attachment to S Avoid dangerous environments. Do not use cool and secure the unit before storing or in unventilated areas or where explosive transporting in a vehicle. vapors or carbon monoxidebuild- --upcould D Store unit and fuel in area where fuel vapors be present. cannot reach sparks or open flames from S Do not set unit on any surface except a water heaters, electric motors or switches, clean, hard area while engine is running. furnaces, etc. Debris such as gravel, sand, dust, grass, etc. could be picked up by the air intake and D Store in a high, cool, dry, indoor area out of thrown out through discharge opening, reach of children. damaging unit, property, or causing serious If situations occur which are not covered in this injury to bystanders or operator. manual, use care and good judgment. If you S Donotoverreachorusefromunstablesur-needassistance,call1- --800- --554- --6723. faces such as ladders, trees, steep slopes, SPECIAL NOTICE: Exposure to vibrations rooftops, etc. Keep firm footing and balance through prolonged use of gasoline powered at all times. hand tools could cause blood vessel or nerve S Never place objects inside the discharge damage in the fingers, hands, and joints of peo opening; always direct the blowing debris ple prone to circulation disorders or abnormal away from people, animals, glass, and solid swelling. Prolonged use in cold weather has objects such as trees, automobiles, walls, etc. The force of air can cause rocks, dirt, or been linked to blood vessel damage in other- sticks to be thrown or to ricochet which can wise healthy people. If symptoms occur such as hurt people or animals, break glass, or numbness, pain, loss of strength, change in skin cause other damage. color or texture, or loss of feeling in the fingers, S Check air intake opening frequently. Keep hands, or joints, discontinue the use of this tool vents and discharge opening free of debris and seek medical attention. An anti- --vibration which can accumulate and restrict proper system does not guarantee the avoidance of air flow. these problems. Users who operate power tools S Never place any object in air intake opening on a continual and regular basis must monitor as this could restrict proper air flow and cause closely their physical condition and the condition damage to the unit. of this tool. SAVE THESE INSTRUCTIONS --4 - - OPERATIONOPERATION KNOW YOUR BLOWER ATTACHMENT READ THIS INSTRUCTION MANUAL AND SAFETY RULES BEFORE OPERATING YOUR BLOWER ATTACHMENT. Compare the illustrations with your unit to familiarize yourself with the location of the various controls and adjustments. Save this manual for future reference. AirIntakeOpeningBlowerDischargeOpeningHangerShaft OPERATING THE COUPLER Your powerhead is equipped with a coupler which enables optional attachments to be installed. The optional attachments are: MODEL: Edger ..................... PPB1000E Cultivator .................. PPB2000T Pruner .................... PPB5000P Pruner .................... PPB5500P Brushcutter* ............... PPB4000C *not designed for use with electric powerheads WARNING: Always disconnect powerhead spark plug (or disconnect powerhead from power source) before removing or installing attachments. REMOVING ATTACHMENT CAUTION: When removing or installing attachments, place the unit on a flat surface for stability. 1. Loosen the coupler by turning the knob counterclockwise. --5 AttachmentCouplerKnobLOOSEN TIGHTEN 2. Press and hold the locking/release button. Locking/Release Button Attachment Upper Shaft Coupler 3. While securely holding the upper shaft, pull the attachment straight out of the coupler. - -- INSTALLING ATTACHMENT INSTALLING ATTACHMENT 1. Remove the shaft cap from the attachment (if present) and discard. 2. Position locking/release button of attachment into guide recess of up...
Este manual também é adequado para os modelos :Sistemas de ventilação - 545212828 (98.46 kb)