Log:
Assessments - 2, GPA: 3.5 ( )

Instruções de Operação AGFA, Modelo SNAPSCAN E42

Fabricante : AGFA
Arquivo Tamanho: 1.07 mb
Arquivo Nome : e1c18c45-17d7-4cee-bde1-47c6805fd3f9.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


These drivers are necessary for detecting the respective scanner. Appendix A: Troubleshooting Windows 98 fails to detect the scanner when you connect it for the first time (PC ONLY). • Check if the scanner is connected with the USB cable to your computer and that the AC adapter is plugged in. It can always happen that a USB port is damaged, therefore try the other USB port of your computer. • Check if the Device Manager finds the USB controller. To check if the USB controller is present in the Device Manager, click with the right mouse button on the icon My Computer and select Properties from the menu that pops up. Select the Device Manager tab from the System Properties dialog box. • If the USB controller ( ) is present in the Device Manager, carry out the scanner installation procedure exactly as described in this manual. • If the USB controller is not present in the Device Manager, carry out the following instructions: 1 Restart your computer. 2 Enable the USB controller in the BIOS settings. Caution: Changing your computer’s BIOS settings is at your own risk! It should be done by system administrators and experienced users only. If you are not familiar with these tasks, ask your computer dealer to do this for you. You typically do this by pressing a key combination during the startup of your PC. Consult your computer manual for more information. 3 Exit and save the changes you made. Your computer is rebooted automatically. • Check again if the Universal serial bus controller is present in the Device Manager. • If the Universal serial bus controller ( ) is present in the Device Manager, carry out the scanner installation procedure exactly as described in this manual. • If the Universal serial bus controller is still not present in the Device Manager, carry out the following instructions: 1. Click the Start button. 2. Select Settings. 3. Select Control Panel. 4. Double-click on the Add New Hardware icon. 5. Attentively follow the instructions that appear on your screen. The Universal Serial Bus controller should now be present in the Device Manager. Carry out the scanner installation procedure exactly as described in this manual. An OEM Windows 98 system was already installed when purchasing your computer (PC ONLY). When you encounter problems during the installation procedure on a PC with a pre-installed Windows 98 system, please contact your PC dealer. Appendix A: Troubleshooting The e-mail function is not working (PC ONLY). The e-mail function is not working (PC ONLY). s means you need a MAPI compatible e-mail client and it also has to be configured correctly. If ScanWise cannot find such a destination, the e-mail destination will NOT be visible in the destination list. Examples of MAPI compatible clients: Microsoft Outlook and Outlook Express, Netscape Messenger, Eudora Pro. Example of a non MAPI compatible client: Compuserve for Windows. Some configuration examples: • If you are using MS Outlook Express v4.x and it does not show up in the ScanWise destination list, choose Options in the Tools menu in Outlook Express and make sure that the following items are checked: • Make Outlook Express my default e-mail program. • Make Outlook Express my default Simple MAPI client. This should solve the problem. • If you are using MS Outlook Express v5, choose Tools, General in the Tools menu in MS Outlook Express. If Outlook is not the default e-mail client, click the ‘Make default’ button. • You can also choose Internet Options, Programs in the Control Panel and indicate your e-mail client there. • Note: If ScanWise cannot find an e-mail destination, ScanWise will ask you to assign another action to the default e-mail button of your scanner. Appendix A: Troubleshooting Appendix B: Technical Information Appendix B: Technical Information Scanner type: SnapScan e42 SnapScan e52 Desktop, flatbed, one pass, 4 buttons of which all are software definable Desktop, flatbed, one pass, 4 buttons of which all are software definable and transparency module Maximum resolution: - optical: - through interpolation: 1200 ppi horizontal x 2400 ppi vertical 9600 ppi horizontal x 9600 ppi vertical - Internal sample depth: 16 bits for gray, 48 bits for color Scanning speed: - line-art: - gray: - color: 8 ms / line 8 ms / line 23 ms / line Maximum scanning area (for reflective scanning only): 216 x 297 mm (8.5 '' x 11.7 '') Maximum scanning area for transparency scanning (SnapScan e52): 5 negatives or transparencies 3 slides Lamp for reflective scanning: Cold cathode Lamp for transparent scanning (SnapScan e52): Cold cathode Power-on to ready time: 15 seconds AC-adapter: - Input voltage: - Input frequency: 100 to 240 V 47 to 63 Hz Power consumption: 25 W Appendix B: Technical Information Dimensions: - length SnapScan e42: - length SnapScan e52: - width: - height: - weight SnapScan e42: - weight SnapScan e52: 496 mm (19.5 “) 501 mm (19.7 “) 337 mm (13.3 “) 94 mm (3.7 “) 3.9 kg (8.6 lb) 4.2 kg (9.24 lb) Interface: USB port Transmission...

Este manual também é adequado para os modelos :
Scanner / Copiadora / MFP - SNAPSCAN E52 (1.07 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias