Instruções de Operação Mustang Survival, Modelo MD3095

Fabricante : Mustang Survival
Arquivo Tamanho: 429.27 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


IS YOUR LP IN GOOD AND SERVICEABLE CONDITION? Check your LP between outings to be sure that it is properly armed; that it is free of rips, tears or holes; that all seams are securely sewn; and that the fabric, straps and hardware are still strong. Inspect the inflatable Compact Tactical Life Preserver Owner’s Manual portion of the LP in accordance with the CARE AND MAINTENANCE INSTRUCTIONS. CARE AND MAINTENANCE INSTRUCTIONS The life preserver and inflation system should be checked at least every three months. In addition, the following maintenance should be performed after each time you wear or inflate the LP. 1) Remove and inspect the CO2 cylinder from the inflator. 2) Check all components for dirt or corrosion. Clean or replace. 3) Check that the CO2 cylinder has not been pierced. Replace with MD3090 33gm CO2 cylinder if necessary (contained in MD3090 accessory pack MA7170). Replace with MD3095 33gm CO2 cylinder if necessary (contained in MD3095 accessory pack MA7203). 4) Check the manual lever to ensure it is in the up and ready position, with the green indicator pin properly installed (MD3090 only). 5) To check the oral inflation valve, fully inflate the MD3090 or MD3095 and hold the valve under water. If bubbles appear, deflate and reinflate to test again. Should the leak persist, take your MD3090 or MD3095 to the point of purchase for proper servicing. 6) Visually examine your MD3090 or MD3095 for damage or excessive abrasion, wear, tear or contamination. Particular attention must be paid to the stitching. If in doubt, send it to the point of purchase for evaluation and/or servicing. 7) Reassemble inflation system parts and repack MD3090 or MD3095 as outlined in previous instructions and illustrations. Leak test: Every three months the LP should be tested for general leakage by orally inflating until firm and let stand overnight. A leaking LP will not hold its firmness and should be replaced. WARNING: If you are not confident in the self inspection and servicing of your LP, in accordance with these instructions, take your MD3090 or MD3095 LP to the point of purchase for professional servicing or contact Mustang Survival (see contact information on back of manual). Compact Tactical Life Preserver Owner’s Manual Safety Accessories MA7170 33 gram CO2 replacement cylinder and green indicator pin. MA7203 33 gram CO2 replacement cylinder/bayonet assembly. MA3090 Chest Belt/Crotch Strap Assembly. Cleaning and Storing Your LP To clean your inflatable LP, remove the CO2 gas cylinder. Hand wash or sponge down in warm, soapy water and rinse with clean water. Hang to dry on a plastic coat hanger. Be sure to replace CO2 cylinder. See Rearming Your LP (for your model). Always store your LP in a warm, dry place out of direct sunlight. How and Why to Test your LP Inflate your LP and try it out in the water to: · Make sure it floats you: Comfortably (when worn properly) Adequately for expected operations (Body shapes/densities affect performance) · Make sure it works: A flow of bubbles should not appear (see CARE AND MAINTENANCE INSTRUCTIONS for leak tests P. 9) It should inflate quick and easily. · Learn how it works by: Activating the CO2 inflation system Re-arming the CO2 inflation system Using the oral inflator tube How do you Test your LP using the Manual Inflator? 1) To test your inflatable LP, you will need: · Your fully armed LP, and Compact Tactical Life Preserver Owner’s Manual · Re-arming kit approved for your LP. 2) Put on the LP. 3) Actuate the inflation system by jerking firmly downward on the beaded handle. The LP should fully inflate within 5 seconds. 4) Get into shallow water, just deep enough that you can stand with your head above the surface. 5) See if the LP will float you adequately just slightly back of vertical. In a relaxed floating position, verify that your mouth is well above the water’s surface. Note the effect of where you hold your legs on how you float. 6) Get out of the water and remove the LP. Remove the used CO2 cylinder from the LP inflator. Completely deflate the LP using the oral inflator. 7) Let the LP dry thoroughly. RE-ARM AND REPACK the LP in accordance with the instructions. How do you Test your LP Using the Oral Inflator? 1) To test your inflatable LP, you will not need any spare parts, or rearming kits. 2) Remove the CO2 cylinder, to prevent inadvertent activation of the manual inflation system which could potentially damage the LP. Inspect the threaded end to confirm it is unused. 3) Put on the LP. 4) Get into shallow water, just deep enough that you can stand with your head above the surface. 5) If you are a weak swimmer or non-swimmer, inflate the LP partially so that you are supported well enough to be able to complete inflation without touching bottom, either orally or manually. Note this level of inflation because it is the minimum needed for you to safely use this inflatable LP. 6) Fully inflate the LP using the oral inflator. 7) See if the LP will float you on your ...

Este manual também é adequado para os modelos :
Equipamentos de Segurança - MD3090 (429.27 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias