Log:
Assessments - 2, GPA: 3.5 ( )

Instruções de Operação TechniSat, Modelo GigaSwitch 9/8

Fabricante : TechniSat
Arquivo Tamanho: 236.81 kb
Arquivo Nome : 6bbdfc48-1334-4091-a30d-68be629449c7.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


. . . . . . . . . . . . . . . . . . . . . . . . . . . .2 2 Safety notes . . . . . . . . . . . . . . . . . . . . . . . .4 3 Installation/mounting . . . . . . . . . . . . . . . . .4 3.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 3.2 Selecting the external unit/LNCs . . . . . . . . . . . . . . . . . . . . . . . . . .4 3.3 Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 3.4 Selecting antenna sockets/connectors . . . . . . . . . . . . . . . . . . . . . .5 3.5 Cascade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 3.6 Energy-saving setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 4 Hints on installation . . . . . . . . . . . . . . . . . .5 5 Trouble.shooting guide . . . . . . . . . . . . . . . .6 6 Technical Data . . . . . . . . . . . . . . . . . . . . . .7 Examples ofinstallations . . . . . . . . . . . . . .8 1 Uses The multi-switches of the GigaSwitch 9/8 series serve to provide satellite IF signals as well as terrestrial signals for up to 16 parties. Distribution examples include the following: > the full bandwidths of two satellites (analogue and digital programmes of the Astra 19,2° and Eutelsat 13° East satellites) or > eight freely selectable polarisation planes. In the satellite band, the branch switches have a slope-rectified amplification/gain, so that distances of up to 100 metres can be bridged without any need for additional equipment. The slope-rectified gain system for terrestrial signals is secure for the future, and can distribute DVB-T signals effectively even in areas receiving a weak signal. Use the mains power adapter supplied to make the connection to mains power. If the GigaSwitch 9/8 G is used without a cascade matrix, it is recommended that the energy- savings switch be set to on. Please note: When using a Cascade GigaSwitch 9/8 K, the energy-savings option must be switched off! 2 Basic unit (for a maximum of 8 parties) Art. No. 0000/3245 Cascade matrix (for a maximum of 8 parties) Art. No. 0000/3246 Mains power adapter Art. No. 0000/3222 3 2 Safety notes For your own protection, you should read the safety notes carefully before installing the equipment. The manufacturer accepts no liability for damage caused by inappropriate handling, or by ignoring the safety instructions. > Components should be mounted in a dry room, on a horizontal plane, consisting or flame-resistant materials. > When installing the equipment keep the electricity switched off. > Ensure the antenna installation is earthed. > Ensure the antenna installation is protected from lightning as per local regulations. > Ensure that you are in compliance with relevant European standards and VDE regulations, where applicable, with regard to electrical safety. > You must comply with national regulations pertaining to broadcast reception installations. > Never open the housing of the equipment. Any repairs necessary should only be carried out by a qualified specialist. If the following apply, disconnect the equipment from the mains power supply, and call a qualified repair person: > the unit was subject to humidity, or water has run into the unit, > in case of malfunctions, > in case of severe external damage. 3 Installation 3.1 General > We recommend a star-shaped distribution, with the distributor being located either in the attic or near the centre of the building. If you are using a cascade matrix, please note Point 3.5. > Please ensure that the levels of the satellite signals fed into the system are approximately equal. This ensures that the very good decoupling characteristics are not limited. > As cables are very sensitive to damage, you should install these as late as possible duriung the building process. If possible, lay the cables inside a protective tube or pipe. Do not bend cables too sharply! > Install the equipment while the electricity is switched off, or disconnected. 3.2 Selecting the external unit/LNCs > You may use Quatro or Dual-Output LNCs. Please note the maximum possible current strength for inputs, as per the technical data. > Quatro-Switch LNCs, Twin LNCs and Single Universal V/H LNCs are not suitable. > The current feeding the LNCs ia approx. 18V (load-dependant). 3.3 Cable > Because of the amplification provieded by the units, you can use small-calibre, easy- to-use cables in spite of the higher damping this means. > When connecting the LNCs with the multi-switch, resp. several multi-switches with each other, we recommend the use of MULTYMEDIA cable (Art. No. 0001/3014). > we recommend you use mini coaxial cable to connect the multi-switch with the antenna sockets. > To isntall longer sections of cable to connect to the antenna sockets, please use the low-damping co-axial cable CoaxSat 2150. > Damping values are specified in Point 6. > Please use crimp-type connectors wherever possible! 4 Insulation should be stripped f...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias