|
Facilidade de uso
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70283501 11 Operation TMB2136N Figure 6 Dual Digital Timer Control RQ Control Suffix 1. Select HIGH, MED, LOW or NO HEAT by turning the temperature knob. 2. Set the HEAT TIME for the number of minutes (from 0-60) desired. 3. Set the COOL DOWN TIME for the number of minutes (from 0-15) desired. 4. Select reversing or nonreversing cylinder rotation setting, if applicable. 5. Press and release START button to start tumbler. Display will show minutes remaining before end of cycle. NOTE: One touch drying is available for repetitive loads. If the START button is pressed while the machine is in Idle Mode, when the display is dark, the tumbler will repeat the last drying cycle. If the cycle time is adjusted before the cycle is started, the time displayed when the start button was pressed will be used for future cycles. IMPORTANT: To stop the tumbler at any time during the cycle, OPEN DOOR. If the loading door or lint panel door is opened during the cycle, the heating system will shut off and the motor will stop. To restart the cycle, both doors must be closed and the START button must be pressed in. If the load cools to 90° F before cool down time expires, the control will flash “Lr” (load ready) in the heat time display. If the door is not opened, the tumbler completes the selected cool down time. If the door is opened after reaching “Lr” temperature, the cycle will be terminated. NOTE: If display shows an error code, refer to Error Codes section. 6. When the cycle is complete, open door and remove the laundry. Anti-wrinkle feature will tumble the load without heat for 30 seconds every 2 minutes for 1 hour OR until the loading door is opened. NOTE: This machine includes an anti-wrinkle/ extended tumble feature. After the drying cycle is complete, the cylinder will tumble without heat every few minutes. The intermittent tumbling will continue for one hour or until the door is opened. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Operation To Program a Short Test Cycle: 1. Unplug machine power cord. 2. Write down machine control dip switch settings, then set them all to the off position. Refer to Figure 7. 3. Plug machine in and start a cycle. NOTE: With all control dip switches off, the total cycle time will be 1 minute long. 4. Once all testing is complete, unplug machine and re-set dip switches to their original settings. 5. Plug machine in. Error Codes Figure 7 TMB2216N 12345678ON12345678 To reduce the risk of electric shock, fire, explosion, serious injury or death: • Disconnect electric power to the tumbler before servicing. • Close gas shut-off valve to gas tumbler before servicing. • Close steam valve to steam tumbler before servicing. • Never start the tumbler with any guards/panels removed. • Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumbler is properly grounded. W002 WARNING OP Display Open thermistor error Definition • Check thermistor. Replace if inoperative. • Check wiring diagram between control and thermistor. Refer to wiring diagram for proper wiring. • Check control. Replace if inoperative. Corrective Action SH AF - 1 started AF - 2 Airflow switch failed to close after cycle started Shorted thermistor error Airflow switch closed when cycle • • • Check thermistor. Replace if inoperative. • Check wiring between control and thermistor. Refer to wiring diagram for proper wiring. • Check control. Replace if inoperative. Check airflow switch. Replace if inoperative. Check airflow switch. Replace if inoperative. 70283501 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 13 Operation Ignition Control Operation Power Up After 24 VAC is applied to the ignition control pins 24V and GND, the Diagnostic LED on the ignition control will turn orange/yellow. If a fault is detected the ignition control will enter Lockout Mode. If no faults are detected, the Diagnostic LED will turn Green and the ignition control will enter Standby Mode. Standby Mode While in Standby Mode, the ignition control will continually monitor the system for faults. Once 24VAC is applied to terminals TH and GND on the control, the ignition control will enter Start Up Mode. Start Up Mode During Start Up Mode, the ignition control will monitor the system for faults and begin the ignition sequence. If no faults are present, the ignition control will begin the ignition sequence by entering an 18 second waiting period. During this time the Green LED on the ignition control will switch between Red and Green, before maintaining a Green color. After the waiting period, the ignition control will turn on the igniter and gas valve. The igniter will remain on until a flame is sensed, or up to 10 seconds. Once a flame has been sensed the ignition control will stop sparking, the gas valve will remain on and ignition control will enter Run Mode. If a flame is not sensed, the ignition...
Este manual também é adequado para os modelos :Máquinas de lavar - 170 Pound Capacity (591.32 kb)