OPERATIONAL MODE Always know the operational mode of the nailer before using. Failure to know the operational mode could result in death or serious personal injury. SINGLE SEQUENTIAL MODE This mode requires the trigger to be pulled each time a nail is driven. The nailer can be actuated by depressing the WCE against the work surface followed by pulling the trigger. The trigger must be released to reset the tool before another nail can be driven. CHECKING THE WORK CONTACT ELEMENT (WCE) Check the operation of the Work Contact Element (WCE) trip mechanism before each use. The WCE must move freely without binding through its entire travel distance. The WCE spring must return the WCE to its fully extended position after being depressed. Do not operate the nailer if the WCE trip mechanism is not operating properly. Personal injury may occur. ! CAUTION ! WARNING Recommended Hookup Quickplug Quickcoupler Air hose Quick-plug (Optional) Quickcoupler (Optional) Oiler Regulator Filter 150 PSI WP 3/8” I.D. Operating Instructions 50 PSI Min. 100 PSI Max. movement (C) ToRuortnateer movement 4. Utiliser un regulateur de pression sur le compresseur avec une pression de service de 0 a 862 kPa. Un regulateur de pression est indispensable pour maintenir la pression de service de la cloueuse entre 345 et 690 kPa. MODE D’EMPLOI Toujours determiner le mode d’operation avant d’utiliser la cloueuse. Sinon, il y a risque de mort ou de blessures graves. MODE SEQUENTIEL UNIQUE La gachette doit etre tiree chaque fois qu’un clou est enfonce. La cloueuse peut etre actionnee en placant le mecanisme de declenchement WCE contre la surface de travail et ensuite en tirant sur la gachette. La gachette doit etre relachee afin de rajuster l’outil avant d’enfoncer un autre clou. VERIFIER LE MECANISME DE DECLENCHEMENT PAR CONTACT (WCE) Verifier le fonctionnement du mecanisme de declenchement par contact (WCE) avant chaque usage. Le WCE doit fonctionner librement sans se gripper a travers la distance totale. Le ressort WCE doit retourner le WCE a sa position etendue apres qu’il a ete appuye. Ne pas utiliser la cloueuse si le mecanisme de declenchement WCE ne fonctionne pas correctement. Ceci peut causer des blessures personnelles. ! ATTENTION ! AVERTISSEMENT 1. Debrancher la source d’air de la cloueuse. 2. Enlever tous les clous du chargeur (voir Chargement / Dechargement) 3. S’assurer que la gachette et le mecanisme de declenchement (WCE) bougent du haut en bas sans grippage. 4. Brancher a nouveau la source d’air a la cloueuse. 5. Appuyer le mecanisme de declenchement par contact (WCE) sur la surface de travail sans actionner la gachette. La cloueuse NE DOIT PAS FONCTIONNER. Si l’ejection d’un clou se produit sans que l’on actionne la gachette, ne pas utiliser cet appareil. Il y a risque de blessures. 6. Oter la cloueuse de la surface de travail. Le mecanisme de declenchement par contact (WCE) doit redescendre a sa position initiale. Actionner la gachette. La cloueuse NE DOIT PAS FONCTIONNER. Si l’ejection d’un clou se produit lorsqu’on releve la cloueuse, ne pas utiliser celle-ci. Il y a risque de blessures. Instructions d’utilisation Branchement Recommande Bouchon Rapide Raccord Rapide Tuyau A Air Bouchon Rapide (Optionnel) Raccord Rapide (Optionnel) Graisseur Regulateur Filtre 3-Fr 7. Depress the Work Contact Element (WCE) against the work surface. Pull the trigger. The nailer MUST OPERATE. LOADING/UNLOADING THE NAILER 1. Always connect the tool to the air supply before loading fasteners. 2. Push down on the latch. Pull back on the magazine cover. 3. Insert a stick of nails (see "Fasteners" section) into the magazine. Make sure the pointed ends of the nails are resting on the bottom ledge of the magazine when loading. Make sure the nails are not dirty or damaged. 4. Push the magazine cover forward until the latch catches. 5. Always unload all fasteners before removing tool from service. Unloading is the reverse of loading, except always disconnect the air supply before unloading. ADJUSTING THE NAIL PENETRATION The air-powered finishing nailer is equipped with an adjustable depth of drive feature. This allows the user to determine how deep a fastener will be driven into the work surface. 1. Adjust operating pressure so nails are driven consistently. Do not exceed 100 PSI. 2. To drive the nail shallower, turn the wheel (C) to right to the extent desired. 3. To sink a nail deeper, turn the wheel (C) to left to the extent desired. 4. Make sure trigger and work contact element (WCE) move freely up and jammed fastener. 5. Remove the jammed fastener, using pliers or a screwdriver if required. 6 Rotate door back into the closed position. 7. Push button down again to lift the hook. Close the door and release the button to reengage the hook with the nose. 8. Make sure the trigger and work contact element (WCE) move freely up and down without sticking or binding. TECHNICAL SUPPORT Please call our Toll-Free Helpline at 1-866-220-2097 with any questions rega...