Log:
Assessments - 1, GPA: 3 ( )

Instruções de Operação Grizzly, Modelo G6046

Fabricante : Grizzly
Arquivo Tamanho: 749.15 kb
Arquivo Nome : 0d21ee96-d468-cd64-7db5-b33f49ab4de2.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


In addition, this nailer discharges at 85-90 decibels. To protect your hearing, always wear ANSI approved ear protection when operating this nailer. Never point this nailer at yourself or another person! Always pay attention to the direction this nailer is pointed. Use this tool with respect and caution to lessen the possibility of operator or bystander injury. Ignoring this warning may result in serious personal injury. G6045/G6046/G6047 18 Gauge Brad Nailer -3 -4- G6045/G6046/G6047 18 Gauge Brad Nailer INTRODUCTION Commentary Most importantly, we stand behind our tools. If you have any service questions or parts requests, please call or write us at the location listed below. Grizzly Industrial, Inc. 1203 Lycoming Mall Circle Pennsdale, PA 17756 Phone: (570) 546-9663 Fax: (800) 438-5901 E-Mail: techsupport@grizzly.com Web Site: We are proud to offer the Grizzly Model G6045/G6046/G6047 18 Gauge Brad Nailer. This model is part of a growing Grizzly family of fine power tools. When used according to the guidelines set forth in this manual, you can expect years of trouble-free, enjoyable operation and proof of Grizzly’s commitment to customer satisfaction. This model features 360° adjustable exhaust, a convenient side-loading magazine, a safety trigger and a durable plastic carrying case. We are pleased to provide this manual with the Model G6045/G6046/G6047. It was written to encourage safety considerations and guide you through general operating procedures and maintenance. This manual represents our effort to produce the best documentation possible. The specifications, details, and photographs in this manual represent the Model G6045/G6046/G6047 as supplied when the manual was prepared. However, owing to Grizzly’s policy of continuous improvement, changes may be made at any time with no obligation on the part of Grizzly. If you have any comments regarding this manual, please write to us at the address below: Grizzly Industrial, Inc. C/O Technical Documentation P.O. Box 2069 Bellingham, WA 98227-2069 Read the manual before assembly and operation. Become familiar with this tool, its safety instructions, and its operation before beginning any work. Serious personal injury may result if safety or operational information is not understood or followed. Compressed Air System The Models G6045 & G6046 are designed to be operated at 60-100 psi. The Model G6047 is designed to be operated at 70110 psi. Do not exceed the maximum operating pressure for your model. Before using your new nailer, install the included 3.8" quick connect fitting. Install a female 3.8" fitting on the air hose. Regulate the air pressure on your air compressor to barely over the minimum psi for your model. Many pneumatic tools benefit from an in- line filter/lubricator/regulator unit. This attachment is connected by hoses between the air compressor and the nailer. Using this unit protects your tool from damaging water build-up, allows you to adjust and maintain constant air pressure to your tool, and saves you the inconvenience of having to manually lubricate your tool every time you use it. Check the current Grizzly catalog for availability of this unit. If you plan on installing a filter/lubricator/regulator unit in your compressed air system, always follow the connection instructions that come with the unit. Exceeding the maximum permissible operating pressure may cause the nailer to explode, blowing metal fragments in all directions. To protect yourself from serious personal injury, DO NOT allow your air compressor to exceed the recommended pressure when connected to this nailer! Safety Yoke Mechanism A safety yoke mechanism (bump fire) on the nose of the nailer acts as a secondary safety device. When the trigger is pressed, the nailer will not fire until the safety yoke mechanism is depressed. Before you use your nailer for the first time, check the safety yoke mechanism to ensure proper function. To do this: 1. Make sure the nailer is disconnected from the air supply! 2. Make sure the magazine is empty and contains no nails. 3. Make sure the trigger and the safety yoke mechanism move up and down without sticking. 4. Connect the nailer to the air supply. 5. Without pressing the trigger, depress the safety yoke mechanism against a scrap piece of wood that is clean and free of any knots, nails, or other foreign objects. If the nailer does not fire, then the safety yoke mechanism is working correctly. If the nailer does fire when you do this, immediately disconnect the nailer from the air supply and call our customer service for help. Similarly if the nailer fires when the trigger is pulled, without the safety yoke mechanism being depressed, then the nailer is not working properly. If either of these two conditions develop after you have used your nailer for a period of time, check the lubrication of these mechanisms. The safety yoke is a mechanical device that can fail. Never rely on the safety yoke mechanism as an excuse...

Este manual também é adequado para os modelos :
Pistola de pregos - G6047 (749.15 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias