|
Facilidade de uso
SUPPLY SOURCE: Use only clean regulated compressed air as a power source for this tool. NEVER USE OXYGEN, COMBUSTIBLE GASES, OR BOTTLED GASES, AS A POWER SOURCE FOR THIS TOOL AS TOOL MAY EXPLODE. REGULATOR: A pressure regulator with an operating pressure of 0 - 125 p.s.i. (0 - 8.79 kg/cm2) is required to control the operatiing pressure for safe operation of this tool. Do not connect this tool to air pressure which can potentially exceed 200 p.s.i. (14 kg/cm2) as tool may fracture or burst, possibly causing injury. OPERATING PRESSURE: Do not exceed recommended maximum operating pressure as tool wear will be greatly increased. The air supply must be capable of maintaining the operating pressure at the tool. Pressure drops in the air supply can reduce the tool’s driving power. Refer to “TOOL SPECIFICATIONS” for setting the correct operating pressure for the tool. FILTER: Dirt and water in the air supply are major causes of wear in pneumatic tools. A filter will help to get the best performance and minimum wear from the tool. The filter must have adequate flow capacity for the specific installation. The filter has to be kept clean to be effective in providing clean compressed air to the tool. Consult the manufacturer’s instructions on proper maintenance of your filter. A dirty and clogged filter will cause a pressure drop which will reduce the tool’s performance. LUBRICATION Frequent, but not excessive, lubrication is required for best performance. Oil added through the air line connection will lubricate the internal parts. Use BOSTITCH Air Tool Lubricant, Mobil Velocite #10, or equivalent. Do not use detergent oil or additives as these lubricants will cause accelerated wear to the seals and bumpers in the tool, resulting in poor tool performance and frequent tool maintenance. If no airline lubricator is used, add oil during use into the air fitting on the tool once or twice a day. Only a few drops of oil at a time is necessary. Too much oil will only collect inside the tool and will be noticeable in the exhaust cycle. COLD WEATHER OPERATION: For cold weather operation, near and below freezing, the moisture in the air line may freeze and prevent tool operation. We recommend the use of BOSTITCH WINTER FORMULA air tool lubricant or permanent antifreeze (ethylene glycol) as a cold weather lubricant. CAUTION: Do not store tools in a cold weather environment to prevent frost or ice formation on the tools operating valves and mechanisms that could cause tool failure. NOTE:Some commercial air line drying liquids are harmful to “O”-rings and seals – do not use these low temperature air dryers without checking compatibility. -5 LOADING THE N100C/N100CPP/N130C SERIES COIL NAILER EYE PROTECTION which conforms to ANSI specifications and provides protection against flying particles both from the FRONT and SIDE should ALWAYS be worn by the operator and others in the work area when connecting to air supply, loading, operating or servicing this tool. Eye protection is required to guard against flying fasteners and debris, which could cause severe eye injury. The employer and/or user must ensure that proper eye protection is worn. Eye protection equipment must conform to the requirements of the American National Standards Institute, ANSI Z87.1 and provide both frontal and side protection. NOTE: Non-side shielded spectacles and face shields alone do not provide adequate protection. TO PREVENT ACCIDENTAL INJURIES: •Never place a hand or any other part of the body in nail discharge area of tool while the air supply is connected. • Never point the tool at anyone else. • Never engage in horseplay. • Never pull the trigger unless nose is directed at the work. •Always handle the tool with care. • Do not pull the trigger or depress the trip mechanism while loading the tool. Canister cover Canister latch Canister bracket Canister bottom Feed pawl Door 1. Open the magazine: pull down down latch and swing door open. Swing magazine cover open. 2. Check adjustment: the nailer must be set for the length of nail to be used. Nails will not feed smoothly if the magazine is not correctly adjusted. To change setting: a) Release the canister latch on the rear of the canister. b) Pull out canister bottom by swinging right to left until tabs disengage. c) Inside the canister bracket are settings in inches and millimeters. The canister is adjusted correctly when the length of the nail being used is shown in the window of the canister bottom. 3. Load the coil of nails: IN. MM Place a coil of nails over the post in the canister. Uncoil 1 3/4 (45) enough nails to reach the feed pawl, and place the second 3 1/4 (83) 2 (50) Canister nail between the teeth on the feed pawl. The nail heads fit in bracket 2 1/4 (57) slot on nose. 2 1/2 (65) 4. Swing cover closed. 2 3/4 (70) 3 (75) 5. Close the door. Check that latch engages. (If it does not engage, check that Canister bottom the nail heads are in the slot on the nose). Note: The canister is adjusted correctl...
Este manual também é adequado para os modelos :Pistola de pregos - N100C (269.79 kb)
Pistola de pregos - N130C (269.79 kb)