Log:
Assessments - 3, GPA: 3.3 ( )

Instruções de Operação Campbell Hausfeld, Modelo FP2040

Fabricante : Campbell Hausfeld
Arquivo Tamanho: 3.47 mb
Arquivo Nome : 98a18de9-8157-44ed-8f17-fe73e1c81b99.pdf
Língua de Ensino: enesfr
Ir para baixar



Facilidade de uso


Attach chuck or other tool to open end of hose. Turn the regulator on. In the ON position, the compressor pumps air into the tank. It shuts off automatically when unit reaches its maximum preset pressure. In the OFF position, the pressure switch cannot function and the compressor will not operate. Make sure switch is in OFF position when connecting or disconnecting power cord from electrical outlet. ASME SAFETY VALVE Do not remove or ! WARNING attempt to adjust the safety valve! Figure 3 This valve should be checked occasionally by pulling the ring by hand. Air may leak even after ring has been released. However, if the leaking continues for an extended period of time, or if the safety valve is stuck and cannot be activated by the ring, the safety valve MUST be replaced. (Note: Valve will reset when tank pressure reaches 40-50 PSI.) REGULATOR KNOB 1. This knob controls air pressure to an air operated tool or paint spray gun. 2. Turn knob clockwise to increase air pressure. 3. To lower air pressure turn knob counterclockwise. 4. Turn fully counterclockwise to shut off flow of air completely. Maintenance Disconnect power source then release all pressure from the system before attempting to install, service, relocate or perform any maintenance. ! WARNING MOISTURE IN COMPRESSED AIR Moisture in compressed air will form into droplets as it comes from an air compressor pump. When humidity is high or when a compressor is in continuous use for an extended period of time, this moisture will collect in the tank. When using a paint spray or sandblast gun, this water will be carried from the tank through the hose, and out of the gun as droplets mixed with the spray material. IMPORTANT: This condensation will cause water spots in a paint job, especially when spraying other than water based paints. If sandblasting, it will cause the sand to cake and clog the gun, rendering it ineffective. A filter in the air line (MP3105), located as near to the gun as possible, will help eliminate this moisture. Figure 4 Check compressor often for any visible problems and follow maintenance procedures each time compressor is used. 1. Pull ring on safety valve and allow it to snap back to normal position. Safety valve must ! WARNING be replaced if it cannot be actuated or it leaks air after ring is released. 2. Turn compressor off and release pressure from system. Drain moisture from tank by opening drain cock underneath tank. Tilt tank to remove all moisture. 3. Clean dust and dirt from motor, tank, air lines and pump cooling fins while compressor is still OFF. LUBRICATION This is an oilless type compressor requiring no lubrication. THERMAL OVERLOAD PROTECTOR This compressor is ! CAUTION equipped with an automatic reset thermal overload protector which will shut off motor if it becomes overheated. If thermal overload protector shuts motor OFF frequently, look for the following causes. 1. Low voltage. 2. Clogged air filter. 3. Lack of proper ventilation. If the thermal ! CAUTION overload protector is actuated, the motor must be allowed to cool down before start-up is possible. The motor will automatically restart without warning if left plugged into electrical outlet and unit is turned on. STORAGE 1. When not in use, store hose and compressor in a cool dry place. 2. Drain tank of moisture. 3. Disconnect hose and hang open ends down to allow any moisture to drain. 4 FP2040 Troubleshooting Chart Symptom Possible Cause(s) Corrective Action Compressor will not run 1. No power or switch in OFF position 1. Make sure compressor is plugged in and switch is ON 2. Blown fuse 2. Disconnect compressor from power source then remove pump shroud. Replace fuse (Part. No. FP200352AV) 3. Motor overheated 3. Allow compressor to cool for approximately 30 minutes so thermal overload switch will reset. If unit still does not start, empty air from tank and refer to 4. Tank pressure at maximum actions 1 and 2. 4. Release air from tank 5. Breaker open 5. Reset, determine cause of problem 6. Pressure switch bad 6. Replace pressure switch Fuses blow/circuit breaker trips repeatedly Never use an extension cord with this product ! CAUTION 1. Incorrect size fuse, circuit overloaded 2. Defective check valve 1. Check for proper fuse in supply circuit. Disconnect other electrical appliances from circuit or operate compressor on its own branch circuit 2. Replace check valve assembly Do not disassemble check valve. With air in tank, bleed tank first. ! DANGER Thermal overload protector cuts out repeatedly 1. Low voltage 2. Lack of proper ventilation/room temperature too high 3. Check valve malfunction 4. Compressor valves failed 1. Eliminate extension cord, check with voltmeter 2. Move compressor to well ventilated area 3. Replace check valve assembly 4. Replace pump assembly Do not disassemble check valve. With air in tank, bleed tank first. ! DANGER Knocks, rattles, excessive vibration 1. Loose bolts, tank not level 2. Defective bearing on eccentric or mo...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias