6. ThedryerMUSTbedisconnectedfromthegas supply piping system during any pressure testing of the gas supply piping system at test pressuresinexcessof1/2psig(3.45kPa). 7. ThedryerMUSTbeisolatedfromthegassupplypiping system during any pressure testing of the gas supply piping system at test pressures equal toorlessthan1/2psig(3.45kPa). 8. Connections for the gas supply must comply with the Standard for Connectors for Gas Appliances,ANSIZ21.24.5Installation Requirements WARNING FIREHAZARDFailure to follow these instructions can create excessivedryingtimesandfirehazards. WARNING FIREHAZARDDonotinstallaclothesdryerwithflexibleplasticormetalfoilventingmaterials.Flexibleventingmaterials are known to collapse, be easily crushed and trap lint. These conditions will obstruct clothes dryer airflow and increase the risk of fire. Exhaust system requirements If your present system is made up of plastic duct or metal foil duct, replace it with a rigid or semi-rigid metal duct. In Canada and the United Statesifmetal(foiltype)ductisinstalled,itmustbe of a specific type identified by the appliance manufacturer as suitable for use with clothes dryers and in the United States must also comply with the Outline for Clothes Dryer Transition Duct, UL standard 2158A. Also, ensure the present duct is free of any lint prior to installing dryer duct. Useonly4inch(10.2cm)diameter(minimum)rigidorflexiblemetalductandapprovedventhoodwhichhasaswing-outdamper(s)thatopenwhenthe dryer is in operation. When the dryer stops, the dampers automatically close to prevent drafts and the entrance of insects and rodents. To avoid restricting the outlet, maintain a minimum of 12 inches(30.5cm)clearancebetweentheventhoodand the ground or any other obstruction. CorrectIncorrectCorrectIncorrectThe following are specific requirements for proper and safe operation of your dryer. Gas supply requirements WARNING EXPLOSIONHAZARDUncoated copper tubing will corrode when subjectedtonaturalgas,causinggasleaks. Use ONLY black iron, stainless steel, or plastic- coated brass piping for gas supply. 1. InstallationMUSTconformwithlocalcodes,orin the absence of local codes, with the National FuelGasCode,ANSIZ223.1(latestedition). 2. Thegassupplylineshouldbe1/2inch(1.27cm)pipe. 3. Ifcodesallow,flexiblemetaltubingmaybeused to connect your dryer to the gas supply line.ThetubingMUSTbeconstructedofstainless steel or plastic-coated brass. 4. ThegassupplylineMUSThaveanindividualshutoff valve. 5. A1/8inch(0.32cm)N.P.T.pluggedtapping, accessiblefortestgaugeconnection,MUSTbe installed immediately upstream of the gas supply connection to the dryer. 6. ThedryerMUSTbedisconnectedfromthegas supply piping system during any pressure testing of the gas supply piping system at test pressuresinexcessof1/2psig(3.45kPa). 7. ThedryerMUSTbeisolatedfromthegassupplypiping system during any pressure testing of the gas supply piping system at test pressures equal toorlessthan1/2psig(3.45kPa). 8. Connections for the gas supply must comply with the Standard for Connectors for Gas Appliances,ANSIZ21.24. Installation Requirements Exhaust system requirements, continued WARNING FIRE HAZARD A clothes dryer must be exhausted outdoors. Do not exhaust dryer into a chimney, a wall, a ceiling, an attic, a crawl space or any concealed space of a building. A clothes dryer produces combustible lint. If the dryer is not exhausted outdoors, some fine lint will be expelled into the laundry area. An accumulation of lint in any area of the home can create a health and fire hazard. The dryer must be connected to an exhaust outdoors. Regularly inspect the outdoor exhaust opening and remove any accumulation of lint around the outdoor exhaust opening and in the surrounding area. WARNING FIRE HAZARD • Do not allow combustible materials (for example: clothing, draperies/curtains, paper) to come in contact with exhaust system. The dryer MUST NOT be exhausted into a chimney, a wall, a ceiling, or any concealed space of a building which can accumulate lint, resulting in a fire hazard. • Do not screen the exhaust ends of the vent system, or use any screws, rivets or other fasteners that extend into the duct to assemble the exhaust system. Lint can become caught in the screen, on the screws or rivets, clogging the duct work and creating a fire hazard as well as increasing drying times. Use an approved vent hood to terminate the duct outdoors, and seal all joints with duct tape. All male duct pipe fittings MUST be installed downstream with the flow of air. WARNING FIRE HAZARD Exceeding the length of duct pipe or number of elbows allowed in the “MAXIMUM LENGTH” charts can cause an accumulation of lint in the exhaust system. Plugging the system could create a fire hazard, as well as increase drying times. Number of 90° turns MAXIMUM LENGTH of 4” (10.2cm) Rigid Metal Duct VENT HOOD TYPE (Preferred) 4” (10.2cm) louvered 2.5” (6.35cm) 0 125 ft. (38.10m) 110 ft. (33.53m) 1 115 ft. (35.05m) 100 ft. (30.48m) 2 105 ft. (32.00m) 90 ft. (27...

Este manual também é adequado para os modelos :
Secadores - 134912700 (2.83 mb)
Secadores - 134709300 (2.83 mb)
Secadores - 137018200 A (2.83 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias