|
Facilidade de uso
A strain relief must be used. Do not loosen the nuts already installed on the terminal block. Be sure they are tight. Use a 3/8” (1cm) deep well socket. 6. Review Gas Requirements section. Remove the pipe thread protective cap. Apply pipe joint compound or about 1 1/2 wraps of Teflon tape over all threaded connections. Pipe joint compound must be resistant to the action of any liquefied petroleum gas. Connect the gas supply to your Dryer. An additional fitting is required to connect the 3/4” (1.9 cm) female thread end of a flexible connector to the 3/8” (1 cm) male threaded end on the dryer. Securely tighten the gas line fitting over threads. Turn on the gas supply. Check all gas connections for leaks using a soap solution. If bubbles appear, tighten the connections and recheck. DO NOT use an open flame to check for gas leaks. 01 Installing Installing your dryer _15 DV218AEW-02568A_EN.indd 15 2008-03-14 .AEA 6:11:22 installing your dryer 3-WIRE system connections 1. Loosen or remove the center terminal block screw. 2. Connect the neutral wire (white or center wire) of the power cord to the center, silver-colored terminal screw of the terminal block. Tighten screw. 3. Connect the other wires to outer terminal block screws. Tighten screws. 4. Tighten the strain relief screws. 5. Insert the tab of the terminal block cover into your Dryer’s rear panel slot. Secure the cover with a hold-down screw. 1. External ground connector 2. Neutral grounding wire (green/yellow) 3. Center silver-colored terminal block screw 4. Neutral wire (white or center wire) 5. 3/4” (1.9 cm) UL-listed strain relief If converting from a 4-wire electrical system to a 3-wire, the ground strap must be reconnected to the terminal block support to ground the Dryer frame to the neutral conductor. WARNING 4-WIRE system connections 1. Remove the center terminal block screw. 2. Connect the ground wire (green or unwrapped) of the power cord to the external ground conductor screw. 3. Connect the neutral wire (white or center wire) of the power cord and the appliance ground wire (green with yellow stripes) under the central screw of the terminal block. 4. Connect the other wires to the outer terminal block screws. Tighten screws. 5. Tighten the strain relief screws. 6. Insert the tab of the terminal block cover into your Dryer’s rear panel slot. Secure the cover with a hold-down screw. 1. External ground connector 2. Green or bare copper wire of power cord 3. 3/4 in. (1.9 cm) UL-listed strain relief 4. Center silver-colored terminal block screw 5. Grounding wire (green/yellow) 6. Neutral wire (white or center wire) 6. With a level, check your Dryer and make necessary adjustments to the leveling legs. 7. At this time, make sure all gas connections (on gas models), exhaust and electrical connections are complete. Plug in your Dryer, and check operation by using the checklist below. 8. (GAS MODELS ONLY : DV218AGW, DV218AGB) The burner may not ignite initially due to air in the gas line. Allowing your Dryer to operate on a heat setting will purge the line. If the gas does not ignite within 5 minutes, turn your Dryer off and wait 5 minutes. Be sure the gas supply to your Dryer has been turned on. In order to confirm gas ignition, check the exhaust for heat. 16_ Installing your dryer DV218AEW-02568A_EN.indd 16 2008-03-14 .AEA 6:11:22 FINAL INSTALLATION CHECKLIST . Dryer is plugged into electrical outlet and is properly grounded. . Exhaust ductwork is hooked up and joints are taped. . Plastic flexible duct is NOT used. . Used rigid or stiff-walled flexible metal vent material. . Dryer is leveled and is sitting firmly on the floor. . Gas models – gas is turned on with no gas leaks. . Start your dryer to confirm that it runs, heats, and shuts off. 01 Installing Installing your dryer _17 DV218AEW-02568A_EN.indd 17 2008-03-14 .AEA 6:11:23 installing your dryer DRYER EXHAUST TIPS Plastic or non-metal flexible duct presents a potential fire hazard. WARNING 1. Make sure you dryer is installed properly so it exhausts air easily. 2. Use a 4” diameter rigid metal duct. Tape all joints, including at the dryer. Never use lint-trapping screws. 3. Keep ducts as straight as possible. 4. Clean all old ducts before installing your new Dryer. Be sure the vent flap opens and closes freely. Inspect and clean the exhaust system annually. Don’t let a poor exhaust system slow drying by: 1. Restricting your Dryer with a poor exhaust system. 12 2. Using a plastic, thin foil, or non-metal flexible duct. 3. Unnecessarily using long ducts that have many elbows. 4. Allowing crushed or clogged ducts and vent. 3 4 18_ Installing your dryer DV218AEW-02568A_EN.indd 18 2008-03-14 .AEA 6:11:25 DOOR REVERSAL 1. Unplug the power cord. 2. Remove two door hinge screws. 3. Lift the door and remove it. 8. Reinsert the black screw in the other hole. 4. Remove a screw on the Frame Front Reinsert the screw (Step 4) on the Frame Front 5. Remove the two screws on the opposite side of the door hinge. 1...
Este manual também é adequado para os modelos :Secadores - DV218AE (2.29 mb)