Log:
Assessments - 3, GPA: 3.3 ( )

Instruções de Operação Samsung, Modelo DV209AG

Fabricante : Samsung
Arquivo Tamanho: 5.04 mb
Arquivo Nome :
Língua de Ensino: enes
Ir para baixar



Facilidade de uso


• That a flexible plastic duct is not used. • To Inspect and clean all lint buildup from inside the existing duct. • The duct is not kinked or crushed. • The exhaust hood damper opens and closes freely. The static pressure in any exhaust system must not exceed 0.83 inches of water column, or be less than 0. This can be measured while the Dryer is running with a manometer at the point where the exhaust duct connects to the Dryer. A no-heat setting should be used. The Dryer tumbler should be empty and the lint filter clean. IMPORTANT TO INSTALLER Please read the following instructions carefully before installing the dryer. These instructions should be kept for future reference. REMOVE THE DOOR FROM ALL DISCARDED APPLIANCES TO AVOID THE DANGER OF A CHILD WARNING SUFFOCATING. LOCATION CONSIDERATIONS The dryer should be located where there is enough space at the front for loading the Dryer, and enough space behind for the exhaust system. This Dryer is factory-ready for rear exhaust. To exhaust out the bottom or the left, use the accessory exhaust kit. Instructions are included with the kit. It’s important to make sure the room has enough fresh air. The Dryer must be located where there is no air-flow obstruction. On gas Dryers, adequate clearance as noted on the data plate must be maintained to ensure adequate air for combustion and proper Dryer operation. THE DRYER MUST NOT BE INSTALLED OR STORED IN AN AREA WHERE IT WILL BE EXPOSED TO WATER AND/OR WEATHER. THE DRYER AREA IS TO BE KEPT CLEAR OF COMBUSTIBLE MATERIALS, GASOLINE, AND OTHER FLAMMABLE VAPORS AND LIQUIDS. A DRYER PRODUCES COMBUSTIBLE LINT. THE AREA AROUND THE DRYER SHOULD BE KEPT LINT-FREE. ALCOVE OR CLOSET INSTALLATION The Dryer must be exhausted to the outside to reduce the risk of fire when installed in an alcove or WARNING closet. • No other fuel-burning appliance should be installed in the same closet as the Dryer. • WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED TO THE OUTDOORS. See EXHAUST INFORMATION section. • Minimum clearances between the Dryer and adjacent walls or other surfaces are: 2” in front, 17” on top, 1” on either side, and 2.375” in the back. • The closet front must have two unobstructed air openings for a combined minimum total area of 72 in. with 3” minimum clearance on the top and bottom. A louvered door with equivalent space clearance is acceptable. 01 installing installing your dryer _9 DV218AEW-02568A-02_EN.indd 9 2009-01-09 .AAu 11:43:28 installing your dryer MOBILE HOME INSTALLATION The installation of the Dryer in mobile homes must conform to the Manufactured Home Construction and Safety Standard Title 24 CFR, Part 32-80 {formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD (Part 280), 1975} for the United States) or CSA Standards Z240 (for Canada). When installing a Dryer in a mobile home, provisions for anchoring the Dryer to the floor must be made. Locate an area that has adequate fresh air. A minimum of 72 in. (183 cm.) of unobstructed space is required. Call 1-800-SAMSUNG for information on purchasing the Floor Anchoring Kit as an accessory. All mobile home installations must be exhausted to the outside with the exhaust duct termination securely fastened to the mobile home structure, using materials that will not support combustion. The exhaust duct may not terminate underneath the mobile home. See Exhausting section for more information. EXHAUSTING Exhausting the Dryer to the outside will prevent large amounts of lint and moisture from being blown into the room. In the United States: • All dryers must be exhausted to the outside. • The required exhaust duct is 4inch(102mm) in diameter. • Only those foil-type flexible ducts, if any, specifically identified for use with the appliance by the manufacturer and that comply with the Outline for Clothes Dryer Transition Duct, Subject 2158A, shall be used. • The duct shall not be assembled with screws or other fastening means that extend into the duct and catch lint. In Canada: • Only those foil-type flexible ducts, if any, specifically identified for use with the appliance by the manufacturer shall be used. • All dryers must be exhausted to the outside. • The exhaust duct should be 4inch (102mm) in diameter. Outside the U.S. and Canada: • Refer to the local codes. The dryer must be exhausted to the outside to reduce the risk of fire when installed in an WARNING alcove or closet. NEVER USE A PLASTIC OR NON-METAL FLEXIBLE DUCT. If your existing ductwork is plastic, non-metal, or combustible, replace it with metal. Use only a metal exhaust duct that is non-flammable to ensure containment of exhaust air, heat, and lint. 10_ installing your dryer DV218AEW-02568A-02_EN.indd 10 2009-01-09 .AAu 11:43:28 GAS REQUIREMENTS Use only natural or LP (liquid propane) gases. THE INSTALLATION MUST CONFORM WITH LOCAL CODES, OR IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL FUEL GAS CODE ANSI/Z223.1, LATEST REVISION (FOR THE UNITED STATES), ...

Este manual também é adequado para os modelos :
Secadores - DV209AE (5.04 mb)
Secadores - Electric Dryers DV218A (5.04 mb)
Secadores - Gas Dryer DV218A (5.04 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias