Instruções de Operação Kenmore, Modelo 110.8787

Fabricante : Kenmore
Arquivo Tamanho: 1.68 mb
Arquivo Nome : c706a552-8de1-4145-8ba1-17f2f11e25e5.pdf
Língua de Ensino: enes
Ir para baixar



Facilidade de uso


Side view - closet or confined area B. Closet door with vents *Required spacing **For side or bottom venting, 0" (0 cm) spacing is allowed. Recessed or closet installation - Dryer on pedestal 27" 31..." 1" 1" 1"* 5"** (68.6 cm) (2.5 cm) (2.5 cm) (2.5 cm) (80 cm) (12.7 cm) A B A. Recessed area B. Side view - closet or confined area *Required spacing **For side or bottom venting, 0" (0 cm) spacing is allowed. 18" min.* (45.72 cm) 14" max.* (35.6 cm) Installation spacing for cabinet installation ¦ For cabinet installation, with a door, minimum ventilation openings in the top of the cabinet are required. 7"* (17.8 cm) 7"* (17.8 cm) 9"* (22.9 cm) 5"**31..." 1"* 1" 27" 1" (12.7 cm) (80.0 cm) (68.6 cm)(2.5 cm) (2.5 cm)(2.5 cm) *Required spacing **For side or bottom venting, 0" (0 cm) spacing is allowed. Recommended installation spacing for recessed or closet installation, with stacked washer and dryer The dimensions shown are for the recommended spacing. 48 in.2 * (310 cm2) 24 in.2 * 3"* (7.6 cm) 3"* (7.6 cm) 1"* (2.5 cm) (155 cm2) *Required spacing 6"* (15.2 cm) 76" (193 cm) 1" 27" 1" (2.5 cm) (68.6 cm) (2.5 cm) 5"* (12.7 cm) *Required spacing Mobile home - additional installation requirements This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280). Mobile home installations require: ¦ Metal exhaust system hardware, which is available for purchase from your local Sears store or Sears Service Center. ¦ Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening. Electrical Requirements It is your responsibility ¦ To contact a qualified electrical installer. ¦ To be sure that the electrical connection is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70-latest edition and all local codes and ordinances. The National Electric Code requires a 4-wire supply connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations. A copy of the above code standards can be obtained from: National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269. ¦ To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit. ¦ Do not use an extension cord. ¦ If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate. Electrical Connection To properly install your dryer, you must determine the type of electrical connection you will be using and follow the instructions provided for it here. ¦ If local codes do not permit the connection of a neutral ground wire to the neutral wire, see “Optional 3-wire connection” section. ¦ This dryer is manufactured ready to install with a 3-wire electrical supply connection. The neutral ground wire is permanently connected to the neutral conductor (white wire) within the dryer. If the dryer is installed with a 4-wire electrical supply connection, the neutral ground wire must be removed from the external ground conductor screw (green screw), and secured under the neutral terminal (center or white wire) of the terminal block. When the neutral ground wire is secured under the neutral terminal (center or white wire) of the terminal block, the dryer cabinet is isolated from the neutral conductor. ¦ A 4-wire power supply connection must be used when the appliance is installed in a location where grounding through the neutral conductor is prohibited. Grounding through the neutral is prohibited for (1) new branch-circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductors. If using a power supply cord: Use a UL listed power supply cord kit marked for use with clothes dryers. The kit should contain: ¦ A UL listed 30-amp power supply cord, rated 120/240 volt minimum. The cord should be type SRD or SRDT and be at least 4 ft (1.22 m) long. The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends. ¦ A UL listed strain relief. If your outlet looks like this: 4-wire receptacle (14-30R) Then choose a 4-wire power supply cord with ring or spade terminals and UL listed strain relief. The 4-wire power supply cord, at least 4 ft (1.22 m) long, must have four 10-gauge copper wires and match a 4-wire receptacle of NEMA Type 14-30R. The ground wire (ground...

Este manual também é adequado para os modelos :
Secadores - 8789 (1.68 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias