Log:
Assessments - 4, GPA: 3.8 ( )

Instruções de Operação Kenmore, Modelo 110.9656

Fabricante : Kenmore
Arquivo Tamanho: 3.57 mb
Arquivo Nome : f77b9ae7-a656-47cd-a560-29c1ba3a1e54.pdf
Língua de Ensino: enes
Ir para baixar



Facilidade de uso


• Flexible metal vent must be fully extended and supported when the dryer is in its final position. • Remove excess flexible metal vent to avoid sagging and kinking that may result in reduced airflow and poor performance. • Do not install flexible metal vent in enclosed walls, ceilings or floors. Elbows 45°elbowsprovidebetterairflowthan90°elbows. Good Better Clamps Use clamps to seal all joints. Exhaust vent must not be connected or secured with screws or other fastening devices that extend into the interior of the duct. Do not use duct tape. Clamp Exhaust Recommended hood styles are shown here. B (10.2 cm) A. Louvered hood style B. Box hood style The angled hood style (shown here) is acceptable, "<'k"_-k_2,/_ ,, (6.4cm) An exhaust hood should cap the vent to prevent rodents and insects from entering the home. Exhaust hood must be at least 12" (30,5 cm) from the ground or any object that may be in the path of the exhaust (such as flowers, rocks or bushes, snow line, etc.), Do not use an exhaust hood with a magnetic latch. Improper venting can cause moisture and lint to collect indoors, which may result in: [] Moisture damage to woodwork, furniture, paint, wallpaper, carpets, etc. [] Housecleaning problems and health problems. Choose your exhaust installation type Recommended exhaust installations Typical installations vent the dryer from the rear of the dryer. Other installations are possible. B ......................... F i ..................................... i G A. Dryer B. Elbow C. Wall D. Exhaust hood E. Clamps F. Rigid metal or flexible metal vent G. Vent length necessary to connect elbows H. Exhaust outlet Optional exhaust installations This dryer can be converted to exhaust out the right side, left side, or through the bottom. Contact your local dealer to have the dryer converted. Fire Hazard Cover unused exhaust holes with the following kit: 279818 (white) Contact your local dealer. Failure to follow these instructions can result in death, fire, electrical shock, or serious injury. A B A. Standard rear offset exhaust installation B. Left or right side exhaust installation C. Bottom exhaust installation (not an option with pedestal installations) Alternate installations for close clearances Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown. Refer to the manufacturer's instructions. f \\\ \ AB A. Over-the-top installation (also available with one offset elbow) B. Periscope installation NOTE: The following kits for close clearance alternate installations are available for purchase. For further information, please call 1-800-4-MY-HOME ®(1-800-469-4663), • Over-the-Top Installation: Part Number 26-49900 • Periscope Installation (For use with dryer vent to wall vent mismatch): Part Number 26-49901 -Less than 5" (12.7 cm) mismatch Part Number 26-49908 -5" (12.7 cm) to 18" (45.72 cm) mismatch Part Number 26-49904 -18" (45.72 cm) to 29" (73.66 cm) mismatch Part Number 26-49905 -29" (73.66 cm) to 50" (127 cm) mismatch Special provisions for mobile home installations The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside. Determine vent path • Select the route that will provide the straightest and most direct path outdoors. • Plan the installation to use the fewest number of elbows and turns. • When using elbows or making turns, allow as much room as possible. • Bend vent gradually to avoid kinking. • Use the fewest 90 ° turns possible, Determine vent length and elbows needed for best drying performance • Use the Vent system chart below to determine type of vent material and hood combinations acceptable to use, • NOTE: Do not use vent runs longer than those specified in the Vent system chart. Exhaust systems longer than those specified will: • Shorten the life of the dryer. • Reduce performance, resulting in longer drying times and increased energy usage, The Vent system chart provides venting requirements that will help to achieve the best drying performance, Vent system chart NOTE: Side and bottom exhaust installations have a 90 ° turn inside the dryer. To determine maximum exhaust length, add one 90 ° turn to the chart. Number of Type of Box or Angled 90° turns vent Iouvered hoods or elbows hoods 0 Rigid metal 64 ft (20 m) 58 ft (17.7 m) Flexible metal 36 ft (11 m) 28 ft (8.5 m) 1 Rigid metal 54 ft (16.5 m) 48 ft (14.6 m) Flexible metal 31 ft (9.4 m) 23 ft (7 m) 2 Rigid metal 44 ft (13.4 m) 38 ft (11.6 m) Flexible metal 27 ft (8.2 m) 19 ft (5.8 m) 3 Rigid metal 35 ft (10.7 m) 29 ft (8,8 m) Flexible metal 25 ft (7.6 m) 17 ft (5,2 m) 4 Rigid metal 27 ft (8,2 m) 21 ft (6.4 m) Flexible metal 23 ft (7 m) 15 ft (4,6 m) 1. Install exhaust hood. Use caulking compound to seal exterior wall opening around exhaust hood. 2. Connect vent to exhaust hood. Vent must fit inside exhaust hood. Secure vent to exhaust hood...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias