Log:
Assessments - 2, GPA: 4.5 ( )

Instruções de Operação Miller Electric, Modelo 383

Fabricante : Miller Electric
Arquivo Tamanho: 2.2 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Routine Maintenance ik ± Disconnect power before maintaining. ^ Maintain more often during severe conditions. 3 Months Replace unreadable labels WARNlrt Ji — J»w Repair or replace cracked weld cable Clean and tighten weld terminals 6 Months Blow out or vacuum inside. Remove drive roll and carrier. Apply light coat of oil or grease to drive motor shaft. 5-2. Circuit Breaker CB1 ik > 1 Circuit Breaker CB1 CB1 protects the unit from overloading of drive motor M1. If CB1 opens, wire feeding stops. 2 Welding Gun Check gun liner for blockage or kinks. 3 Wire Drive Assembly Check for jammed wire, binding drive gear or misaligned drive rolls. Allow cooling period and reset breaker. Close door. 5-3. Unit Overload Thermal switches TP1 in XFMR and TP2 in SR1 protect the unit from damage due to overheating. If the thermal indicator illuminates, wait for unit to cool allowing fan motor to run before trying to weld. If unit is cool and no weld output continues, contact Factory Authorized Service Agent. OM-223 194 Page 18 5-4. Troubleshooting £k rr Trouble Remedy No weld output; wire does not feed. Be sure line disconnect switch is On (see Section 3-8). Replace building line fuse or reset circuit breaker if open. Reset circuit breaker CB1 (see Section 5-2). Secure gun trigger connections. Check continuity of power switch S1 and replace if necessary. Check main transformer T1 for signs of windig failure. Check continuity across windings and check for proper connections. Check secondary voltages. Replace T1 if necessary. Check continuity of thermostats TP1 and TP2. Replace TP1 and TP2 if necessary. Check main control board PC1 and connections and replace if necessary. No weld output; wire feeds. Connect work clamp to get good metal to metal contact. Replace contact tip (see gun Owner's Manual). An overload condition occurred (see Section 5-3) Check diodes in main rectifier SR1, and replace if necessary. Check stabilizer Z1 for signs of winding failure. Check continuity across windings and check connections. Replace Z1 if necessary. Check main transformer T1 for signs of winding failure. Check continuity across windings and check connections. Check secondary voltages. Replace T1 if necessary. Check voltage switch(s). Replace if necessary. Low weld output. Connect unit to proper input voltage or check for low line voltage (see Section 3-6). Check input voltage jumper links and correct position if necessary (see Section 3-6). Check main rectifier SR1, and replace if necessary. Check voltage switch(s). Replace if necessary. Low, high, or erratic wire speed. Readjust front panel settings (see Section 4-1). Change to correct size drive rolls. Readjust drive roll pressure (see Section 3-11). Replace inlet guide, contact tip, and/or liner if necessary. Check position of input jumper links (see Section 3-6). Check Wire Speed control R1, and replace if necessary. Check diodes in main rectifier SR1, and replace if necessary. Check main control boarf PC1 and connections and replace if necessary. No wire feed. Reset circuit breaker CB1 (see Section 5-2). Rotate Wire Speed control R1 to higher setting (see Section 4-1). Clear obstruction in gun contact tip or liner (see gun Owner's Manual). OM-223 194 Page 19 Notes OM-223 194 Page 20 SECTION 6 - ELECTRICAL DIAGRAMS S2 GRN/ZEL пь GM/TEL ° rh r H h H h S3 10 "0 l~L? П' IN RECTC IN TRANS ' 16 O—1-O—^ O^-0—4-0-2-o-£- o-*-0-2-o- /о 400V PL1 TP1 Este manual também é adequado para os modelos :
Máquinas de soldar - 273 (2.2 mb)
Máquinas de soldar - 271 (2.2 mb)
Máquinas de soldar - 293 (2.2 mb)
Máquinas de soldar - 333 (2.2 mb)


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias