Log:
Assessments - 3, GPA: 3.3 ( )

Instruções de Operação American Power Conversion, Modelo SU1400XLT

Fabricante : American Power Conversion
Arquivo Tamanho: 1.43 mb
Arquivo Nome : ASTE-6Z8L95_R0_EN.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


All rights reserved; reproduction in whole or in part without permission is prohibited. Smart-UPS is a registered trademark of APC. All other trademarks are the property of their respective owners. Contents Contents 1. Introduction ................................................ 3 2. Hardwire Kit Overview................................... 5 3. Hardwire Kit Contents ................................... 6 4. Required Materials and Tools ...........................8 4.1 Required Materials ..............................................8 4.2 Required Tools ...................................................8 5. Installation .................................................. 9 5.1 Installing the Hardwire Kit on 100V or 120V Tower Units .............................................................. 10 5.2 Installing the Hardwire Kit on 208V Tower Units......19 5.3 Installing the Hardwire Kit on 100V and 120V Rack Mount Units ....................................................29 5.4 Installing the Hardwire Kit on 208V Rack Mount Units .............................................................. 37 2 1. Introduction 1. Introduction These instructions describe how to safely install the accessory hardwire kit on the following Smart-UPS models. SU1400XLT SU2200 SU3000 SU1400RMXLT SU2200XL SU3000T SU2200XLT SU3000RM SU2200RM SU3000J SU2200RMXLT SU3000RMJ SU2200XLRM SU2200J This kit provides the necessary hardware to install direct wiring for input connection, output connection or both. Carefully read these instructions in their entirety before continuing. WARNING! Only qualified service personnel or electricians may perform the following procedure. The electrical terminals exposed in the following procedures will be energized if the UPS is on or plugged in. Make sure the UPS is both unplugged and off. CAUTION! When the input and/or output panels are replaced with this kit, the standard circuit breakers are eliminated. Properly rated overcurrent protection must be supplied at the source to protect both the wiring, the UPS, and the loads attached to it. Where an individual load has a lower rating for its source overcurrent protection, additional properly rated overcurrent protection must be supplied for the load(s). The maximum allowed overcurrent protection for each model is given in the table below. A lower value may be used, but may result in a reduction of power that can be supplied by the UPS. Model Number Overcurrent Protection Maximum Input Current Nominal Voltage 1400XLT 1400RMXLT 20A 20A 12A 12A 208V 208V 2200J 30A 24A 100V 2200 30A 21A 120V 2200RM 30A 21A 120V 2200XL 30A 24A 120V 2200RMXL 30A 24A 120V 2200XLT 20A 16A 208V 2200RMXLT 20A 16A 208V 3000J 40A 30A 100V 3000RMJ 40A 30A 100V 3000 40A 28A 120V 3000RM 40A 28A 120V 3000T 20A 18A 208V 2. Hardwire Kit Overview 2. Hardwire Kit Overview The Smart-UPS hardwire kit provides the panels and mounting hardware for both floor standing (tower) and rack mount Smart-UPS models. This kit is used to replace the power distribution outlets and/or input power cord that is originally furnished with the UPS. The input and output panels are designed with knockouts for use with standard sized cable or conduit clamps. Cable or conduit clamps are not included in this kit. NOTE: If your Smart-UPS is serial number 9603xxxxxxx or less, you may be unable to install this hardwire kit to your UPS. Con tact your dealer for an alternative solution. 6 3. HardwireKitContents The Smart-UPS hardwire kit contains the following items: Figure 3-1 Contents of the Hardwire Kit Output Panel - For tower unit. Colored black. Input Panel - For tower unit. Colored black. Access Panel - For tower unit. Colored black. Access Panel - For rack mount unit. Colored silver. Output Panel - For rack mount unit. Colored silver. Input Panel - For rack mount unit. Colored silver. Hardware Bag - Contains: 2 red wire nut connectors 4 green self-tapping screws (10-32 x 3/8”) 8 self-locking panel screws (8-32 x 3/8”) 2 wire harness mounting screws (8-32 x 3/4”) 1 terminal block label 1 maximum input label 1 receptacle option label sheet Rack Mount Wire Harness Bracket -Used to mount the wire har ness assembly (#10) inside a rack mount unit. 4-Wire Jumper Harness (qty 2) -An extension used to attach wire harness input wires to the input connector inside the UPS. 3-Wire Jumper Harness -An extension used to attach wire harness input wires to the input connector inside the UPS. Wire Harness Assembly - Provides screw terminals for connecting external input and output wiring to the wiring harness. In-line connectors allow for connection between the wiring harness and the UPS. 4. Required Materials and Tools 4. Required Materials and Tools 4.1 Required Materials The following materials are not included in the hardwire kit and must be supplied by the purchaser: • Electrical cable or wiring - Cable or wiring must be of sufficient current carrying capacity to safely accommodate the attached loads. Refer to local electrical ...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias