Log:
Assessments - 4, GPA: 4 ( )

Instruções de Operação Intelligent Motion Systems, Modelo IM1007 I/IE

Fabricante : Intelligent Motion Systems
Arquivo Tamanho: 584.25 kb
Arquivo Nome : 634ed9bf-11d2-aa84-d91f-162d5f184615.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


2 Pin Description ............................................................................................... 3 Absolute Maximum Rating ............................................................................. 4 Electrical Specifications ................................................................................. 5 Mechanical Specifications .............................................................................. 6 Thermal Specifications...................................................................................7 Over Temperature Protection .................................................................. 7 Output Current ............................................................................................... 8 Determining Output Current .................................................................... 8 Setting Output Current ............................................................................ 9 Encoder Interface ........................................................................................... 9 Motor ............................................................................................................ 10 Motor Selection ..................................................................................... 10 Connecting the Motor ........................................................................... 11 Connecting Power ........................................................................................ 12 Optically Isolated Inputs (Limit A, Limit B, Home, Party) .............................. 13 General Purpose Inputs ............................................................................... 14 Dedicated Inputs .......................................................................................... 15 Moving Output .............................................................................................. 15 Fault Protection ............................................................................................ 16 Party Line Operation .................................................................................... 17 Party Line Connection (using RS-232 Option) ...................................... 17 +5 VDC Output ............................................................................................ 18 Options/Accessories .................................................................................... 18 Application Notes ......................................................................................... 19 Appendix A: Recommended Cable Configurations ...................................... 20 Warranty ...................................................................................................... 27 IM1007ie Operating Manual Rev 052404 1 APPENDIX A Recommended Cable Configurations: DC Supply to IMS Driver Cable length, wire gauge and power conditioning devices play a major role in the performance of your IMS Driver and Motor. NOTE: The length of the DC power supply cable to the IMS Driver should not exceed 50 feet. Example A demonstrates the recommended cable configuration for DC power supply cabling under 50 feet long. If cabling of 50 feet or longer is required, the additional length may be gained by adding an AC power supply cable (see Examples B & C). Correct AWG wire size is determined by the current requirement plus cable length. Please see the IMS Driver Supply Cable AWG Table in this Appendix. Example A – Cabling Under 50 Feet, DC Power To IMS Driver Ferrite Beads Shielded/Twisted Pair (Wire Size from IMS Driver Supply Cable AWG Table) Shield to Earth Ground on Supply End Only Per Amp DC Voltage from Power Supply 500 .f +- Braided Shield .Type RFI Filter . Required Current +- Cable Length less then 50 Feet 20 Example B – Cabling 50 Feet or Greater, AC Power to Full Wave Bridge NOTE: To Cable A Connect the cable illustrated in Example A to the output of the Full Wave Bridge Full Wave Bridge Braided Shield Shielded/Twisted Pair (Wire Size from IMS Driver Supply Cable AWG Table) . Type RFI Filter . Required Current Transformer : 0 to 28 VAC RMS for 48 VDC Systems 20 to 48 VAC RMS for 75 VDC Systems Shield to Earth Ground on Supply End Only Cable Length 50 Feet or greater +- 21 Example C – Cabling 50 Feet or Greater, AC Power to Power Supply NOTE: the Power Supply Shielded/Twisted Pair (Wire Size from IMS Driver Supply Cable AWG Table) . Type RFI Filter . Required Current Shield to Earth Ground on Supply End Only Braided Shield Cable Length 50 Feet or greater 120 or 240 VAC Dependent on Power Supply Power Supply +-To Cable A DC Volts Out Connect the cable illustrated in Example A to the output of 22 NOTE: These recommendations will provide optimal protection against EMI and RFI. The actual cable type, wire gauge, shield type and filtering devices used are dependent on the customer’s application and system. IMS Driver Supply Cable AWG Table 1 Ampere (Peak) Length (Feet) 10 25 50* 75* 100* Minimu...

Este manual também é adequado para os modelos :
Máquinas de soldar - IM1007 I/IE (584.25 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias