Log:
Assessments - 3, GPA: 4 ( )

Instruções de Operação Emerson, Modelo 90 SERIES 1F95-391

Fabricante : Emerson
Arquivo Tamanho: 1 mb
Arquivo Nome : 0037-6528.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


1 (Blue arrow) Lowers temperature setting (45° F or 7° C minimum) 2 (Red arrow) Raises temperature setting (99° F or 37° C maximum) 3 The multi-color indicator glows: green for 1st stage, yellow for 2ndstage, flashing yellow for 3rd stage, red for emergency heat and flashing red for malfunction condition in system. 4 This button (on top of the cover) lights the display. 5 Used to initiate or review thermostat programming or advance to next program period in programming mode. BACK 6 Used with TIME FWD / TIME to set the clock. 7 Used to adjust the time backward, or to select the previous menu item. 8 Used to adjust the time forward, or to select the next menu item. BACK 9 Used with TIME FWD / TIME to set the current day. 10 Used to advance operation to the next program period or advance to the next day in programming mode. 11 Used to manually override programming to hold at a selected temperature. 12 Used to view ambient humidity or modify humidity setting. 13 Selects fan operation (see The Display page 3). This button is also used to program the fan to run continuously during a program period. 14 Used to enter the service menu to change or reset humidifier, air filter, UV bulb, and service timers. 15 Sets the system mode ( HEATing, EMERgency (Heat Pump models only) , OFF, COOLing, or AUTOmatic changeover) . 16 Used to adjust the clock one hour forward or back. 17 Used to start or return to program operation. 1 LARGE LIGHTED The thermostat display shows the current time and temperature on the left side. The display also shows the temperature you have programmed or set on the right side of your screen. 1 Display system mode ( OFF, AUTO, HOLD, VACA or HUMD). During programming displays the time period ( MOR, DAY, EVE, NHT) being programmed. In the configuration menu, the menu item name is FAN AUTO HRS CHECK BATTERY AM MON 1 2 3 4 567 shown, one word PRGM MODE, EMR, COOL FAN DELA OFF, etc.). 2 CHECK STAT appears when the thermostat detects certain problems within itself. CHECK SYSTEM appears when the themostat detects certain problems in the heating/cooling or humidity system. 3 Indicates the length of time remaining in a temporary hold condition. Also indicates the length of time remaining in VACATION mode. FAN AUTO HEAT F MON 1 8 4 Displays FAN ON when the fan is operating continuously. Displays FAN AUTO when the fan cycles with the heating or cooling system. 5 Displays the setpoint temperature. In HUMD mode, shows humidity setpoint. 6 Alternately displays room temperature and time of day. In HUMD mode, shows actual humidity. 7 Shows the current day of the week. When programming, shows the day(s) being programmed. 8 The word HEAT or COOL will appear above or below the setpoint if area 1 is needed to display other information. 2 INTRODUCTION Introduction ..................................................... 3 Configuration .............................................. 4-11 Manual Operation and Programming ...... 12-17 Features .................................................... 18-26 FAQs .......................................................... 27-32 Troubleshooting ....................................... 33-37 Index ............................................................... 38 Use the tabs at the bottom of the page to quickly locate sections. You will find information about thermostat buttons (page display beginning on page INTRODUCTION Introduction ..................................................... 3 Configuration .............................................. 4-11 Manual Operation and Programming ...... 12-17 Features .................................................... 18-26 FAQs .......................................................... 27-32 Troubleshooting ....................................... 33-37 Index ............................................................... 38 Use the tabs at the bottom of the page to quickly locate sections. You will find information about thermostat buttons (page display beginning on page Thank you for purchasing new White-Rodgers 90 Series thermostat with humidity White-Rodgers has been producing energy saving controls for over 60 years. We have been designing and producing the White-Rodgers 90 Series family of electronic programmable thermostats since 1982. White-Rodgers 90 Series is the third generation of the electronic programmable family. We believe you will find that the White-Rodgers 90 Series is the most user friendly and technologically advanced thermostat and humidity control available today. 3 Introduction Configuration Troubleshooting Programming Features FAQs Index CONFIGURATION CONFIGURATION The configuration menu your system or personal To enter the menu, press TIME FWD and TIME BACK once at the same time. Press TIME FWD to advance through the menu options. Press arrow keys User Configuration Menu Step Press Button(s) Displayed (Factory Default) Press or to select: COMMENTS RefPage 1 TIME FWD 0 F (0) 5 LO to 5 HI Adjusts temperature display high...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias