Log:
Assessments - 3, GPA: 4.3 ( )

Instruções de Operação Crestron electronic, Modelo CHV-TSTAT

Fabricante : Crestron electronic
Arquivo Tamanho: 1.47 mb
Arquivo Nome : chv-tstat_chv-thstat_firmware_up_to_1.1.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Press VIEW to select preferences. Press the Arrow keys (^Ў) to select the value of the parameter. MODEVIEW.... CRESTRONSETUP: SYSTEM PERFHeat Anticipator: Cool Anticipator: Auto Mode DdBand: HP Balance Pt: AUX Balance Pt: 332000150Anticipators(valid selections are 1 through 6) Low number = more frequent cycles and fasterresponse (tighter regulation) High number = less frequent cycles and slowerresponse (looser regulation) Auto Mode Dead Band(valid selections are 2 through 60) The minimum differential between heatingand cooling setpoints (Dual Setpoint Autoset to Yes in Display Options on page 19). HP Balance Point (Heat Pump Systems only) Minimum outdoor temperature at which the heatpump will run (requires outdoor sensor) AUX Balance Point (Heat Pump with Aux only) Maximum outdoor temperature at which Aux HeatSystem supplements the heat pump (requiresoutdoor sensor) NOTE: Setting the HP Balance Point to 0. can disable Heat pump. Setting the Aux Balance Point to 90. can disable Aux Heat. 3. Humidifier/Fan Options Press the MODE button to access the HUMIDIFIER/FAN OPTIONS. Press VIEW to select option. Press the Arrow keys (^Ў) to select the value of the parameter. MODEVIEW.... CRESTRONSETUP: HUM/FAN OPTSDisp Humidity Pgs? Cold Weather Comp? Run Fan in Ht Calls? YYNDisplay Humidity Pages? Cold Weather Compensation? Run Fan in Heat Calls? Yes or NoYes or No. Modifies the humidifier outputto prevent condensation on the windows. Requires an outdoor temperature sensor. Yes or NoMost heating systems run the fanautomatically. If your heating systemrequires fan control, select Yes. 4. Device Options Press the MODE button to access the DEVICE OPTIONS. Press VIEW to select options. Press the Arrow keys (^Ў) to select the value of the parameter. MODEVIEW.... CRESTRONSETUP: DEVICE OPTSNetwork ID: LCD ContrastFirmwareVersion [1.1] Bld 1332A5Select Network IDValid entries are 03 to FE in Hexto match the network ID set for thethermostat in SIMPL WindowsSelect LCD Screen Contrast(1 Lighter through 10 Darker) 5. Screen Options Press the MODE button to access the SCREEN OPTIONS. Press VIEW to select each option. Press the Arrow keys (^Ў) to select the value of the parameter. NOTE: The pages in the following setup screen refer to the screens that are seen by the user when the VIEW key is pressed in the normal operating mode. Outdoor Page – Temperature/humidity of the outside sensor (if the optional sensor is installed). May also be imported from Cresnet. Global Page – Temperature/humidity selection for entire house. Allows setting of temperature/humidity throughout a multi-thermostat system from a single location. Must be wired and programmed as part of a Cresnet system. Remote Function Page(s) – When part of a Cresnet system, remote function pages allows control of other functions (for example: lights, alarms, etc.). Each of the two pages has two definable buttons. The up ^and down Ў keys are set by indirect text for each page, refer to “CHV-TSTAT and CHV-THSTAT Advanced Symbol” on page 27. MODEVIEW.... CRESTRONSETUP: SCRN OPTIONSDisp Global Page? Disp Outdoor Page? Disp Rem Func Pg1? Disp Rem Func Pg2? YYYYDisplay Global Page? Yes or NoDisplay Outdoor Page? Yes or NoDisplay Remote Function Pages? Yes or No 6. Display Options Press the MODE button to access the DISPLAY OPTIONS. Press VIEW to select options. Press the Arrow keys (^Ў) to select the value of the parameter. MODEVIEW.... CRESTRONSETUP: DISP OPTIONSTemperature Units: Temp display offset: Dual Setpoint Auto: Main Scn Lwr Obj: F00YHM0F or 0COffset (-6 to +60) Allows the user to adjustthe displayed temperatureMain Screen Lower Object(Under the Temperature Display) HM - Displays HumidityNA - No DisplayOD - Outdoor temperatureUse Dual Setpoint AutomaticYes or NoAllows an automatic selection ofsetpoint range. NOTE: Dual Setpoint Automatic – Selecting Yes allows the user to explicitly set the heat and cool setpoints in auto mode. Selecting No shows one setpoint and the thermostat automatically selects the operating systems to maintain that setpoint temperature. NOTE: The Offset option permits recalibration of the room temperature sensor. There are various reasons why users may want to adjust the temperature. The selection number is the number of degrees added or subtracted to the actual temperature. The range is -6° to +6°. Factory default is 0°. This adjustment changes the actual regulated temperature, not just the display. 7. Sensors Press the MODE button to access the SENSORS. Press VIEW to select each sensor type. Press the Arrow keys (^Ў) to select the value of the parameter. NOTE: The sensors are used for Temperature/Humidity Averaging. Choose USE to include each sensor, or OMIT to exclude each sensor in the averaging equation. NOTE: The thermostat will not leave the setup mode unless a valid sensor selection is made. An omitted remote humidity sensor for a CHV-TSTAT does not prevent setup exit. MODEVIEW.... CRESTRONSETUP: SENSORSSensorInternal: Remote 1: Remote 2: T...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias