Log:
Assessments - 3, GPA: 4.3 ( )

Instruções de Operação Hunter Fan, Modelo 44459

Fabricante : Hunter Fan
Arquivo Tamanho: 255.77 kb
Arquivo Nome : 44459.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Leave it in this position if you have a gas furnace or an oil burner. If you have an electric furnace, test to see whether the Heat and Fan come on as expected. If Fan operation is normal, leave the switch in the “HG” position. If the Fan does not come on within a minute of the thermostat calling for Heat, change the switch position to “HE.” The system selector has no effect in the cooling mode. NOTE: “HG” position is for gas and most other systems. “HE” position is for certain electric systems having a fan relay. Furnace or Heat Pump selector (NORMAL – O – B switch) The factory position for this switch is in the NORMAL position. Leave it in this position if you have ANY system that uses gas, oil, electric, or hot water heating. If you have a single-stage Heat Pump (no auxiliary or emergency heat source), then slide the switch to the position that matches your Reversing Valve type. If your heat pump system has a “B” wire, slide the switch to “B” for your reversing valve that activates in HEAT mode. If your heat pump system has an “O” wire, slide the switch to “O” for your reversing valve that activates in COOL mode. 14-15INSTALLATION Selector Switches F°/C° selector (SW5) 12 Hr./24 Hr. selector (SW6) Span selector (SW7) Recovery selector (SW8) HG – HE switchNormal – O – B – switch PAGE 14 * DEFAULT SETTING NORMAL HE HGB O SWITCH SETTING SW NAME ON * OFF SW5 F/C CELSUIS FAHRENHEIT SW6 12/24 24HOURS 12 HOURS SW7 SPAN +2F/-1F +1F/-1F SW8 RECOV. DISABLE ENABLE B99A p1-19 2/7/03 9:58 AM Page 15 Feature Selector Switches: Heat mode, you can select +2°F / – 1° F by sliding the switch to the ALT position. This may be necessary if your heating system F° / C° selector (Fahrenheit / Centigrade) – Switch 5 cycles too rapidly. Your thermostat is set for F° mode from the factory. In order to Auto Recovery selector - Switch 8 change to C° mode, slide the switch to C° and press the reset button on front of the thermostat with a paper clip. Your thermostat is set from the factory with the Auto Recovery Feature enabled, which complies with the EPA ENERGY STAR ® NOTE: Unless the reset button is pressed, the thermostat Program. If you prefer to use normal recovery, slide the switch will not change temperature mode. to the ALT position. 12 Hr. / 24 Hr. selector – Switch 6 Refer to page 30 for a complete discussion of the Auto Recovery feature. Your thermostat is set for normal 12 hour (AM / PM) time format. To change to 24 hour (military) time, slide the switch to Feature Selector Summary: the 24 position. This change may be made without resetting the thermostat, and will automatically change the current time Table B below summarizes the Feature Switches discussed display and all program times in memory. above. A similar table is printed directly on the circuit board for your quick reference. Span selector - Switch 7 Your thermostat is set to cycle at 1° F (0.5°C) above and below the set temperature. If you require slower temperature cycles in Switch Setting Switch Function Alternate Standard SW 5 F° / C° Celsius Fahrenheit SW 6 12 Hr. / 24 Hr. 24 Hour 12 Hour SW 7 Span +2°F / –1°F +1°F / –1°F SW 8 Auto Recovery Disable Enable Table B PAGE 15 B99A p1-19 2/7/03 9:58 AM Page 16 16-17PROGRAMMING Setting Time and Day Remove the mylar label covering the LCD display window before operating thermostat. M Initial display after power-up or reset. The LCD will show the information when batteries are first installed, or after the Reset button is pressed. The AM 12: 00 temperature will update after a few seconds. TEMP 72 EXAMPLE: Set the thermostat to the current time of 9:43 a.m. on Saturday. Refer to Figure at right. HOUR MIN DAY RETURN During time and day setting mode, the temperature and program Sa displays will go blank. AM 9: 43 Press and hold to rapid advance to the current hour. Tap to advance one hour at a time. Note the AM / PM indicator, as the display will cycle through 24 hours. Press and hold to rapid advance to the current minute. Tap to advance one minute at a time. Sa Tap to advance one day at a time. AM 9: 43 When finished, press to return to the Normal time and temperature TEMP 71 display or wait 15 seconds for it to return to Normal mode automatically. PAGE 16 B99A p1-19 2/7/03 9:58 AM Page 17 Auto Programming Studies conducted by the Department of Energy estimate that to Friday, to the same 4 programs as shown in the table, or each setting your thermostat back 10°F (6°C) for two 8-hour periods weekday can have a different set of 4 programs. Similarly weekend during winter can reduce your fuel bill by as much as 33%. By programs, Saturday and Sunday, can be the same 4 programs or setting your thermostat up 5° F (3°C) for two 8-hour periods each weekend day can have a different set of 4 programs. during summer you can reduce your fuel bill up to 25%. Your Hunter thermostat is pre-programmed to meet the ENERGY Your thermostat is capable of holding up to 4 separate programs STAR ® guidelines for energy efficienc...

Este manual também é adequado para os modelos :
Os termostatos - 44459 (255.77 kb)
Os termostatos - 44459 (255.77 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias