Instruções de Operação Aube Technologies, Modelo 44132

Fabricante : Aube Technologies
Arquivo Tamanho: 1.41 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Failure to do so could result in damage to your thermostat and/or your heating and cooling system. Do not restore power until your installation is complete. • This thermostat is designed for use with 24V AC/millivolt systems with a maximum of 1 amp. Higher amp or line voltage systems will cause damage to your system and increase the risk of fire. 44127, 44132 Programmable Thermostat 1 Preparation Gathering Tools and Warnings 1 Old Thermostat Removal 1. Turn off power to your compressor and furnace. 2. Remove the cover to your existing thermostat. Some thermostats may have screws or other locking devices that must first be removed. Once the wallplate is exposed, locate the wire terminals and try to identify the wire designations. If the wire terminals are not visible, they may be connected to the back of the wallplate. Look for any additional screws, tabs, or locking devices to remove the wallplate. See Figure 1. If you are still unable to find the terminals for the wires, it may be necessary to contact the manufacturer of the original thermostat. Installation Mounting the Wallplate 2 Wire Color Wire letter Figure 2. Figure 3b. R, V R Y, Y1, M Y G, F G L, F, X L O, R O B B W2, E, X, Aux E Y2 Y2 C, X, X1, B C Heat Pump W G Y RH C Figure 6. 1. Remove the mounting plate by pulling it straight off the back of the Thermostat. Figure 5. Figure 5. 2. Pull the wires through the back of the mounting plate, ensuring none of the wire labels are removed. Figure 6. Figure 7. bubble level Figure 8. W G Y RH C 3. Using a Phillips Screwdriver, Partially install 1 screw into the top hole of the thermostat. Ensure the thermostat is level using the bubble level on the mounting plate Figure 7., then install the other screw. Tighten both screws until secure. Figure 8. Figure 11. 4. Check the charts on the back of this sheet and identify your system type. They are divided by Conventional and Heat Pump installations. 5. Raise all of the levers on the terminals you will be using. Heat Pump Installation labels are located on the left of the terminal blocks on the mounting plate and Conventional labels are on the right. If your installation does not call for the jumper, remove it now. It is located underneath the wire holes, between the RH and RC terminals on the conventional side. Figure 9. 6. If one of the terminals you need has a tab in front of it, use your finger to break the tab away. Figure 9. Note: Only break tabs you know you will be using. Double check your wiring configuration and make sure you are familiar with the terminals you will be using. 7. Insert the bare end of each wire all the way into the appropriate hole in the terminal block that matches the wire label then lower the lever. This will lock each of the wires in place. Tuck excess wire back into wall after they have been locked in the mounting plate. Note: Do not insert the wires into the holes in the top of the mounting block. The wires should be inserted into the front close to the hole in the mount...

Este manual também é adequado para os modelos :
Os termostatos - 44132 (1.41 mb)
Os termostatos - 44127 (1.41 mb)
Os termostatos - 44132 (1.41 mb)
Os termostatos - 44127 (1.41 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias