Log:
Assessments - 1, GPA: 4 ( )

Instruções de Operação Aube Technologies, Modelo TH115 A/F/AF

Fabricante : Aube Technologies
Arquivo Tamanho: 389.37 kb
Arquivo Nome : TH115-A-F-AF-024T-15S.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


1 to 20% 21 to 40% 41 to 60% 61 to 80% 81 to 100% Notes: ..You can program up to 4 different programs per day. Each day can have different programs. ..It is sometimes faster to program the same schedule for the entire week and then to modify the exception days. To modify: ..Press PGM to access the programming mode ..Press DAY to select the day to be programmed (hold for 3 seconds to select all days of the week). ..Press PGM to select the program number. ..Press HOUR and MIN to set the time or press CLEAR to clear the time (--:-- is disregarded). ..Repeat steps 2 to 4 for remaining programs. ..When completed, press RET to exit mode. NOTE: After 60 seconds of inactivity, the thermostat will automatically exit programming mode. Modify the Schedule Technical Specifications Model: TH115 A / AF / F Display range: 32°F to 140°F (0°C to 60°C) Setting range (ambient): 40°F to 86°F (5°C to 30°C) Setting range (floor limit): 40°F to 104°F (5°C to 40°C) Pre-programmed temperature setpoints: ..Comfort: A/AF: 70°F (21°C) and F: 82°F (28°C) ..Economy: A/AF: 64°F (18°C) and F: 68°F (20°C) ..Vacation: A/F/AF: 50°F (10°C) ..Floor limit:AF: 82°F (28°C) Accuracy:± 0.9°F (0.5°C) Storage:-4°F to 120°F (-20°C to 50°C) Temperature control: Proportional integral adaptive, 15-minute or 15-second heating cycles according to the application and power base. Memory backup: In the event of a power failure, an internal circuit will maintain the programming. Only the time will have to be set if the power failure is more than two (2) hours. The thermostat will return to the same operating mode as set before the power failure. Custom Grid Use this blank grid to record your new schedule. Prog Setpoint MO TU WE TH FR SA SU • Model: • A • F • AF • Temperature display: • °F • °C • Time display: • 12hrs • 24hrs Warranty AUBE TECHNOLOGIES INC. ONE (1) YEAR LIMITED WARRANTY This product is guaranteed against workmanship defects for a one year period following the initial date of purchase. During this period, AUBE Technologies Inc. will repair or replace, at our option and without charge, any defective product which has been used under normal conditions. The warranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged following installation. This warranty cancels and replaces any other manufacturer's express or implied warranty as well as any other company commitment. AUBE Technologies Inc. cannot be held liable for related or random damages following the installation of this product. The defective product as well as the purchase invoice must be returned to the place of purchase or mailed, prepaid and insured, to the following address: Aube Technologies Inc. 705 Montrichard Saint-Jean-sur-Richelieu, Quebec, Canada J2X 5K8 The TH115 is equipped with a remote input which allows connection of a telephone controller (accessory Aube CT240) or any other remote control system. When a signal is received through this input, the TH115 will automatically switch from normal operating mode to Vacation mode ( ), and vice versa when the signal is removed. Activating the Vacation mode There are two ways to activate the Vacation mode: ..From the thermostat, see “Operating Modes” above. ..From a telephone (remote location). For details on how to activate using a telephone, refer to the CT240 Instruction Manual. WARNING: When the Vacation mode is activated remotely, it must be deactivated remotely. Remote Input If you have any questions concerning the installation or programming of the TH115 programmable thermostat, call our technical support team at: Phone: Montreal area:(450) 358-4600 Canada / U.S.:1-800-831-AUBE (2823) Fax: (450) 358-4650 Email: service@aubetech.com Monday to Friday from 8:30 AM to 5:00 PM EST For more information on our products, visit us at: As an ENERGY STAR® partner, Aube Technologies has determined that this product meets the ENERGY STAR guidelines for energy efficiency. 04/08/2003 920-115-007-00-1-A PB112-024T-15S Installation Instructions 24 V Low-Voltage Power Base • Install the control module onto the base. • Applications • Apply power to the heating system. The PB112-024T-15S power base can be used on any TH11x series • Verify the installation by checking that the heating system can be thermostat (with the exception of the TH110 model). This low-voltage turned on or off using the thermostat. power base operates on 15-second cycles and can be connected to a line-voltage load using a solid-state relay. The PB112-024T-15S is compatible with most solid-state relays; however, the following Aube 4.1 Single SSR with Built-in Transformer relays are optimized for use with this power base: • RT850 solid-state relay (SSR) • RT850T solid-state relay (SSR) with built-in 24-V transformer WARNING This power base MUST be used ONLY with solid-state relays. The use of electromechanical relays will result in reduced life expectancy and in the possibility of overheating of these devices. • Suppli...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias