Log:
Assessments - 3, GPA: 3.3 ( )

Instruções de Operação Aube Technologies, Modelo 43355

Fabricante : Aube Technologies
Arquivo Tamanho: 454.04 kb
Arquivo Nome : 43355.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


¦ You may also press the HOME TODAY key while in Temporary Manual Override. The operation is the same as the previous point above. 30OPERATION Energy Monitor The Energy monitor feature measures and stores the 999 Hrs. 59 Min.). By monitoring your energy amount of time the heating and air conditioning sys-usage, you see how much the set-back periods tem operates. Usage can be displayed for Today (since are saving and you can test program adjustment 12am), Yesterday, This Week (since Monday), Last to save even more. Use table on page 17. Week (last Monday through Sunday), and Total (up to ¦ To review energy usage, press to cycle through Today, Yesterday, This Week, Last Week, and Total. Press again to return to normal mode, or wait 15 energy seconds for the display to return to normal mode. You can also return to normal mode at any time by pressing RETURN. ¦ For example: This LCD display shows Today’s usage to be 10 Hours, 26 minutes. ¦ Press and hold for 3 seconds to reset the Energy Monitor’s counters. The display will blink, and all counters will be cleared to zero. energy NOTE: Clearing the Energy Monitor counter will also clear the Filter Monitor counter, as Filter usage and Total Energy usage are the same. Also, clearing the Filter Monitor counter will clear ALL Energy Monitor counters as well. Filter Monitor 2 FILTER Your thermostat also keeps a record of the number of hours your filter has been in use. To maximize your system’s performance and energy efficiency, change or clean your filter regularly. ¦ When the total system run time for heat and cool reaches 400 hours, FILTER will flash on the LCD display to remind you to clean or change your system’s filter. FILTER will continue to flash until the counter is set back to zero. ¦ Press to review total filter usage. The display will filter blink FILTER ,then show the Filter Monitor counter. After 15 seconds, the display will return to normal mode, or you can hit RETURN to exit immediately. The Filter Monitor will display up to 999 hours and 59 minutes of usage. In this example, the counter is at 410 Hours, 26 minutes. ¦ To reset the Filter Monitor counter, depress FILTER for 3 seconds. The display will blink, and the counter will be reset to zero. FILTER NOTE: Clearing the Filter Monitor counter will also clear ALL Energy Monitor counters, as Filter usage and Total Energy usage are the same. Also, clearing the Energy Monitor counters will clear the Filter Monitor counter as well. 32OPERATION Auto Recovery Climate Technology’s Auto Recovery feature meets the ENERGY STAR® guidelines for energy efficiency by allowing the heating or cooling system to recover gradually from an energy-saving setpoint temperature to a comfort setpoint temperature. Auto Recovery calculates how early to turn your system back On, so that the room temperature is already comfortable by the start of the comfort temperature program period. Auto Recovery works in both Heat and Cool modes. For example, in Heat mode, you could have the follow ing programs: Program #4 (Overnight) Program #1 (Morning) Set Temp = 60°F Set Temp = 68°F Time = 10pm Time = 6am The room temperature fell to 60°F overnight. Rather than having the thermostat turning on at 6am, Auto Recovery would note the temperature difference between 60°F and 68°F and turn the Heat on approximately 30 minutes early. Therefore, the room temperature at 6am would be about 68°F instead of 60°F. ¦ When the thermostat is in Auto Recovery mode, the display will alternate RECO with time, and the program indicator will flash. 4 Details of Auto Recovery Operation: ¦ Auto Recovery can be disabled by sliding the Recovery switch on the circuit board to the DISABLE position. Refer to page 13. ¦ Auto Recovery will not operate if Permanent hold, Temporary hold or Home Today is in operation. ¦ Auto Recovery can be canceled manually if HOLD/ RETURN is pressed during the recovery process. If a recovery process is canceled manually then the recovery process will not start again until the next program period starts (an exception is that if time or program is changed then the thermostat will check Auto Recovery conditions immediately). ¦ Auto Recovery will be canceled and change to Home Today mode if HOME TODAY is pressed during the recovery process. ¦ Auto Recovery will be canceled and change to Temporary Manual Override mode if the setpoint is adjusted during the recovery process. ¦ If the system is changed between heat and cool then the thermostat will recalculate Auto Recovery again. Setpoint temperature will be changed to the opposite system’s comfort temperature if the recovery entry criteria are still met. Otherwise, the recovery process will be canceled and return to program control mode. 34OPERATION SPAN Setting Mode Your thermostat is set at the factory to cycle at all conditions. However, if you find your system 1°F (0.5°C) above and below the set temperature. cycling too fast or too slow, then the Span can be (Span = 2) This setting has b...

Este manual também é adequado para os modelos :
Os termostatos - 43355 (454.04 kb)
Os termostatos - 43355 (454.04 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias