Instruções de Operação Aube Technologies, Modelo TH116 A/F/AF

Fabricante : Aube Technologies
Arquivo Tamanho: 275.45 kb
Arquivo Nome : TH116-A-F-AF-024T-15S.pdf

Língua de Ensino: en

O documento está colocado, por favor, espere
O documento está colocado, por favor, espere

Facilidade de uso


To test: ! Press the TEST button: • Successful: TEST warning light is ON and power to heating system is cut off. • Unsucessful: The TEST warning light is OFF. Cut power to heating system from the main power panel and call customer service. " When successful, reset thermostat (STANDBY/ON) to power heating system. NOTE: If the test warning light comes ON during normal operation, cut power to heating system from the main power panel and have an electrician verify the installation. The TH113 and TH116 are equipped with a remote input which allows connection of an optional telephone controller (CT240) or any other remote control system. When a command signal is received through this input, the thermostat automatically lowers its setpoint by 3.5°C. The LED lights up to indicate the signal’s presence (except for GA and GB models). Bypass (not available for GA and GB power base): The TEST button can be used to bypass the signal for a 2-hour period. The LED goes off to indicate the bypass. NOTE: When combined with a GA/GB power base, the TEST button is used only for GFCI testing. The bypass function is not available with these power base models. $ Models: TH113 and TH116 A / AF / F Setting range: 45°F, 59°F to 95°F (7°C, 15°C to 35°C) Potentiometers: minimum: 41°F to 77°F (5°C to 25°C) maximum: 59°F to 95°F (15°C to 35°C) Accuracy: ± 0.9°F (0.5°C) Storage: -4°F to 120°F (-20°C to 50°C) %" AUBE TECHNOLOGIES INC. ONE (1) YEAR LIMITED WARRANTY This product is guaranteed against workmanship defects for a one year period following the initial date of purchase. During this period, AUBE Technologies Inc. will repair or replace, at our option and without charge, any defective product which has been used under normal conditions. The warranty does not cover delivery costs and does not apply to products poorly installed or randomly damaged following installation. This warranty cancels and replaces any other manufacturer's express or implied warranty as well as any other company commitment. AUBE Technologies Inc. cannot be held liable for related or random damages following the installation of this product. The defective product as well as the purchase invoice must be returned to the place of purchase or mailed, prepaid and insured, to the following address: Aube Technologies Inc. 705 Montrichard Saint-Jean-sur-Richelieu, Quebec, Canada J2X 5K8 If you have any questions concerning the TH113 or the TH116 thermostat, call our technical support team at: Phone: Montreal area: (450) 358-4600 Canada / U.S.: 1-800-831-AUBE (2823) Fax: y(450) 358-4650 Email: service@aubetech.com Monday to Friday from 8:30 AM to 5:00 PM EST. For more information on our products, visit us at: & ' Follow the same procedure for the TH116. Power base Control module &' .. .. ( ' 01/08/03 920-113-001-00-1-A PB112-024T-15S Installation Instructions 24 V Low-Voltage Power Base • Install the control module onto the base. • Applications • Apply power to the heating system. The PB112-024T-15S power base can be used on any TH11x series • Verify the installation by checking that the heating system can be thermostat (with the exception of the TH110 model). This low-voltage turned on or off using the thermostat. power base operates on 15-second cycles and can be connected to a line-voltage load using a solid-state relay. The PB112-024T-15S is compatible with most solid-state relays; however, the following Aube 4.1 Single SSR with Built-in Transformer relays are optimized for use with this power base: • RT850 solid-state relay (SSR) • RT850T solid-state relay (SSR) with built-in 24-V transformer WARNING This power base MUST be used ONLY with solid-state relays. The use of electromechanical relays will result in reduced life expectancy and in the possibility of overheating of these devices. • Supplied Parts • One (1) power base • Two (2) plastic anchors • Two (2) mounting screws • Installation Guidelines • For a new installation, choose a location about 1.5 m (5 ft.) above the floor. • The thermostat must be installed on an inside wall facing the heating system (except for floor heating systems). • Avoid locations where there are air drafts (top of staircase, air outlet), dead air spots (behind a door), direct sunlight or concealed chimney or stove pipes (except for floor heating systems). • Installation Procedure The installation must be carried out by an electrician and comply with local electrical codes. • Turn off power to the heating system at the main electrical panel to avoid electrical shock. • Wire the base according to your application. See typical wiring diagrams in sections 4.1 and 4.2. • For a floor heating system installation, connect the floor sensor between the S and R terminals. • Secure the base to the wall using the provided screws and wall anchors. • Configure the switches located on the control module (if any). Refer to the user guide. 4.2 Multiple SSRs with External Transformer Electrical Panel Heater Blue Re...

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias