Log:
Assessments - 4, GPA: 5 ( )

Instruções de Operação Aube Technologies, Modelo SET & SAVE 44155C

Fabricante : Aube Technologies
Arquivo Tamanho: 1.34 mb
Arquivo Nome : 42708.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Verify that the wall plate is visually level and securely tighten both screws. 16 GRCRHY/0W/BRCGY1Y/0W/ BY1Terminal Shield GRCRHY/0W/BRCGY1Y/0W/ BY1Terminal Shield 17 inSTalling ThE ThErMoSTaT, ConT. ConnECTing ThE WirES 1. Loosen, but do not remove, the terminal screws. note: a jumper wire has been provided, connecting the rC and rh terminals for systems that do not provide both an rh and rC wire. if you have both an rh and rC wire, remove this jumper. if you do not have both an rh and rC wire, leave the jumper in place. 2. Match and connect the wires from the wall to the terminals as shown. Wires should be inserted behind the black terminal shields. Tighten each screw after the connection has been made. (The ends of any extra wires should be wrapped in electrical tape and carefully pushed back into the wall.) 3. Push any excess wire length back into the wall to prevent interference. GRCRHYWJumper inSTalling ThE ThErMoSTaT, ConT. ConnECTing ThE WirES 1. Loosen, but do not remove, the terminal screws. note: a jumper wire has been provided, connecting the rC and rh terminals for systems that do not provide both an rh and rC wire. if you have both an rh and rC wire, remove this jumper. if you do not have both an rh and rC wire, leave the jumper in place. 2. Match and connect the wires from the wall to the terminals as shown. Wires should be inserted behind the black terminal shields. Tighten each screw after the connection has been made. (The ends of any extra wires should be wrapped in electrical tape and carefully pushed back into the wall.) 3. Push any excess wire length back into the wall to prevent interference. GRCRHYWJumper 18 DISABLE ENABLE RECOVERY HG HE W/B Y/O RH RC G SYSTEM TYPE STD HP Y1 FAN OPTION AMHEATTThermostat Cover System Switch G RC RH Y/O W/B Y1 DISABLE ENABLE RECOVERY HG HE W/B Y/O RH RC G SYSTEM TYPE STD HP Y1 FAN OPTION AMHEATTThermostat Cover System Switch G RC RH Y/O W/B Y1 inSTalling ThE ThErMoSTaT, ConT. aTTaChing ThE ThErMoSTaT Lift the thermostat cover and set the SYSTEM switch to OFF and the FAN switch to AUTO. 1. Locate the HE/HG switch on the back of the thermostat. Set the switch to HG (default) for gas furnace and oil burners. Set the switch to HE for electric furnaces. (The switch has no effect when the system is set to cooling mode.) 2. Locate the Auto Recovery switch on the back of the thermostat. If you wish to use the Auto Recovery feature, verify that the switch is in the ENABLE position. If you do not wish to use this feature, simply change the switch to the DISABLE position. See pages 44-45 for more information. 3. System type - Locate the SyStem type switch on the back of the thermostat. Select either STD (Standard) or HP (Heat Pump) to match your system. 20 12Tab 12Tab inSTalling ThE ThErMoSTaT, ConT. 4. Place the top of the thermostat over the two tabs on the wall plate. Press the thermostat onto the wall plate and press to snap the bottom tab into place. note: Do not force the thermostat onto the wall plate, as the terminal pins may be damaged. if the thermostat does not snap into place properly, the unit may not work. 5. Insert two AA alkaline batteries. 6. Restore power at the electrical panel or furnace. 22 resetreset SETTingS The default setting of the thermostat is Fahrenheit (Fo). noTiCE: Changing ThiS SETTing Will rESET ThE ThErMoSTaT To faCTorY DEfaulT prograMS. (If no button is pressed for 5 seconds, the unit will return to the Normal Display mode.) To change to Celcius (Co): 1. Press and hold the Up button. 2. Use a paperclip to press the Reset button. 3. Continue to press the Up button, but release the Reset button when the LCD turns on. To reset the unit to Fo, press only the Reset button. 24 day/timeAMPM day/timeAMPM SETTingS, ConT. The default for this thermostat setting is in a 12 hour format. You can change the format to 24 hour format by pressing Day/Time and then Program. The aM/pM indicator will be off when the thermostat is in 24 hour mode. Setting day and time: 1. Press Day/Time. (AM/PM and current hour will flash) 2. Press Up or Down to adjust the setting. 3. Press Day/Time again to adjust the minute setting. 4. Press Day/Time again to adjust the day of the week. 5. Press Day/Time to return to the normal display. You may also press hold/return at any time to return to the normal display. 26 AMHEAT4T AMHEAT4T METhoDS of opEraTion This thermostat gives you the ability to program up to 4 custom temperature settings per day or utilize pre-programmed settings. For manual operation instructions, see pages28-31. To utilize the pre-programmed settings, see pages 32-33. To create custom programs, see pages 34-37. 28 AMHEAT2TH AMHEAT2TH METhoDS of opEraTion, ConT. 1. Manual opEraTion Many people prefer to operate their thermostats manually, adjusting settings as needed. You can either temporarily override the settings for the current program, or permanently override all settings and adjust temperatures manually. If you want to only override the curre...

Este manual também é adequado para os modelos :
Os termostatos - SET & SAVE 44155C (1.34 mb)
Os termostatos - SET & SAVE 44155C (1.34 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias