Log:
Assessments - 4, GPA: 4.3 ( )

Instruções de Operação Carrier, Modelo RAK148P1

Fabricante : Carrier
Arquivo Tamanho: 558.98 kb
Arquivo Nome : 2ee75b2a-1a5d-4c16-bac3-46a65de149a3.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Only one can be selected. Table 2: Terminals for six wires 2 heat/1 cool system (RAK148P1 only) Note: Connect G terminal of thermostat to Zoneline Gl terminal for low fan speed or terminal Gh for high fan speed. Only one can be selected. Configuration mode. The configuration mode is used to set the RAK148P1 and RAK164P1 to match your heating/cooling system. These thermostats function with up to 2-stage heat pump systems (RAK148P1 only). To configure the RAK148P1 and RAK164P1, perform the following steps: Note: Operation being set will blink in the display. 1. Slide the Function switch to the OFF position. 2. Simultaneously hold the < and > buttons in for 6 seconds while the thermostat is in OFF mode. 3. Press the < or > button to change settings within each screen. 4. Press the Hold button to advance to the next screen. Note: The Mode button will return you to the previous screen. 5. To exit configuration mode, slide the Function switch to Heat or Cool. Configuration Mode Settings The setup screens for Configuration Mode are as follows: 1. Temperature Scale (F or C)— Choose Fahrenheit or Celsius. Press the < or > button to select. Press the Hold button to advance to the next screen. 2. Temperature Differential— Stage 1—(1–9°F) (1–5°C)— (Factory Setting is 2°F/1°C for Each Stage)—Set the number of degrees between your “setpoint” temperature and your “turn on” temperature for first stage. Press the < or > button to set differential value. Press the Hold button to advance to the next screen. 3. Temperature Differential—Stage 2—(RAK148P1 only) (1–9°F) (1–5°C)—Set the number of degrees between when stage 1 turns on and stage 2 turns on. Press the < or > button to set differential value. Press the Hold button to advance to the next screen. 4. Minimum Cool Setpoint (60, 64, 66, 68, 70, 72, 74, 76°F) (15, 17, 19, 20, 21, 22, 23, 24°C) Adjust to control the minimum Cool set temperature allowed. Press the < or > button to select. Press the Hold button to advance to the next screen. 5. Maximum Heat Setpoint (65, 70, 72, 74, 76, 78, 80, 85°F) (18, 21, 22, 23, 24, 26, 27, 29°C) Adjust to control the maximum Heat set temperature allowed. Press the < or > button to select. Press the Hold button to advance to the next screen. 6. Room temperature offset (+9°F to –9°F) (+5°C to –5°C) Adjust to calibrate displayed room temperature to match actual room temperature. Press the < or > button to select. Press the Hold button to advance to the next screen. Move the Function switch to Heat or Cool position to lock the settings into memory. Operation. The RAK148P1 and RAK164P1 thermostats have buttons that are used to: • Adjust the setpoints of the thermostat • Set the modes • Program the schedule Setting the Room Temperature (Setpoint Temperature) 1. With the Function switch at Cool or Heat, the current temperature setpoint displays. 2. Press the < or > button until the desired temperature setpoint displays. 3. The new temperature setpoint is automatically saved in memory. Starting the thermostat. CAUTION! Do not use air conditioning when the outdoor temperature is below 50 degrees. This can damage your air conditioning system and cause personal injuries. 1. Move the Fan Auto/On switch to the Auto position. On position runs indoor fan continuously. 2. Move the Function switch AMOFF Time to Cool or Heat, depending Room Temperature on the season. OFF Indicator Testing the thermostat. Once the thermostat is installed, it should be thoroughly tested. CAUTION! Do not use air conditioning when the outdoor temperature is below 50 degrees. This can damage your air conditioning system and cause personal injuries. Note: Before testing the thermostat, move the Fan Auto/On switch to the Auto position. Cool Test 1. Slide Function switch to Cool position. Cool mode screen is displayed. 2. Adjust set temperature so it is 5 degrees below room temperature. AM COOL 3. Air conditioning should come on within a few seconds. 4. Adjust the set temperature so it is 2 degrees above the room temperature and the A/C should turn off. Note: There is a 3 minute time delay and a 3 minute minimum run time for the compressor when it turns on/off. (On some models, the fan may also have a 3 minute minimum run time/off time delay.) Testing the thermostat. Heat Test 1. Slide Function switch to Heat position. Heat mode screen is displayed. 2. Adjust set temperature so it is 5 degrees above room temperature. AM HEAT 3. Heat should come on within a few seconds. 4. Adjust the set temperature so it is 2 degrees below the room temperature and the heat should turn off. Note: There is a 3 minute time delay and a 3 minute minimum run time for the compressor when it turns on/off. (On some models, the fan may also have a 3 minute minimum run time/off time delay). Note: “Quick Heat Recovery” is activated each time the thermostat is switched from Off or Cool modes to Heat mode. Electric heaters are energized until the thermostat set point is reached. Heat pump operation will resume...

Este manual também é adequado para os modelos :
Os termostatos - RAK148P1 (558.98 kb)
Os termostatos - RAK164P1 (558.98 kb)
Os termostatos - RAK164P1 (558.98 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias