Fabricante : Carrier
Arquivo Tamanho: 406.84 kb
Arquivo Nome : 33cs-13so.pdf
|
Facilidade de uso
While holding down the Mode button, press the UP and DOWN ARROW buttons simultaneously. The “Locked” icon will appear on the display. The thermostat is unlocked by performing the same procedure. Press and hold the Mode button. While holding down the Mode button, Press the UP and DOWN ARROW buttons simultaneously. The “Locked” icon will be removed from the display. Set Clock — The Set Clock function allows the user to change the time and day displayed on the thermostat. Press and hold the Mode and Override buttons at the same time until the display changes. The display will show the setup annunciator. The current time will blink on and off. Press the UP ARROW or DOWN ARROW button until the correct time is shown. Hold down the buttons to quickly move through the time display. The AM and PM annunciators will automatically change. To scroll through by hours instead of minutes, hold down the Override button while pressing UP ARROW or DOWN ARROW. To ensure the schedules are properly followed, make sure that AM or PM is correct for the time chosen. When the correct time is shown, press the Mode button to modify the day of the week. The current day will blink on and off. Press the UP ARROW or DOWN ARROW button until the correct day is shown. Press and hold the Mode and Override buttons at the same time again to exit the Set Clock mode. Program Thermostat Schedules — Before programming the thermostat, plan the thermostat daily schedule. The schedule is divided into 7 days (Monday through Sunday). Each day has from 2 to 4 time periods (Occupied 1, Occupied 2, Occupied 3, Unoccupied) depending on the configuration of the thermostat. Each occupied time period has a start time, stop time, heating set point, and cooling set point. The unoccupied time period has a heating set point and a cooling set point. The unoccupied time period is active whenever an occupied time period is not active. Fill in Table 1 as an aid to programming the daily schedules. PROGRAMMING MODE — To program the daily schedules, perform the following procedure: 1. Enter Programming mode by pressing and holding the Mode and UP ARROW buttons. The Occupied 1 annunciator will appear on the thermostat display. Use the UP ARROW or DOWN ARROW button to set the maximum number of Occupied periods for each day. The thermostat can be set to 1, 2, or 3. After the number of Occupied periods has been selected, press the Mode button. See Fig. 3. Fig. 3 — Setting Occupied 1 Set Points 2. The cooling set point for Occupied 1 will be displayed. Use the UP ARROW or DOWN ARROW button to raise or lower the cooling set point until the desired temperature is shown. The range of acceptable values is 35 to 99 F (1 to 37 C). Press the Mode button to continue. See Fig. 3. 3. The heating set point for Occupied 1 will be displayed. Use the UP ARROW or DOWN ARROW button to raise or lower the heating set point until the desired temperature is shown. The range of acceptable values is 35 to 99 F (1 to 37 C). Press the Mode button to continue. See Fig. 3. 4. The cooling set point for Unoccupied will be displayed. Use the UP ARROW or DOWN ARROW button to raise or lower the cooling set point until the desired temperature is shown. The range of acceptable values is 35 to 99 F (1 to 37 C) or ‘‘OF’’ (no unoccupied cooling). To configure the Unoccupied Cooling set point to OF, press the UP ARROW button until 99 F is displayed. Press the UP ARROW button again to display OF. Press the Mode button to continue. 5. The heating set point for Unoccupied will be displayed. Use the UP ARROW or DOWN ARROW button to raise or lower the heating set point until the desired temperature is shown. The range of acceptable values is 35 to 99 F (1 to 37 C) or ‘‘OF’’ (no unoccupied heating). To 105 2 configure the Unoccupied Heating set point to OF, press If only one occupied schedule is selected, the Occupied 2 the DOWN ARROW button until 35 F is displayed. Press and 3 schedules are skipped. If the start time is set later in the the DOWN ARROW button again to display OF. Press day than the stop time, the program will run from midnight of the Mode button to continue. that day to the stop time and then from the start time to midnight. If the same start and stop times are programmed for an 6. The day of the week will be shown. Use the UP ARROW occupancy schedule, the thermostat will be in Occupied mode or DOWN ARROW button to change the day of the for 24 hours. If one occupied period starts or stops within an- week until the desired starting day is shown. Possible other occupied period, the lower numbered schedule has priori- choices are Mo (Monday) through Su (Sunday). Press the ty. For example, if schedule Occupied 3 is running for 24 hours Mode button when the desired day is shown. and Occupied 2 schedule comes on from 1 to 3 PM, the set 7. The Start Time for Occupied 1 will be displayed. Use the points from Occupied 2 are in effect from 1 to 3 PM. UP ARROW or DOWN ARROW button to raise or low- OVERRIDING THE...
Este manual também é adequado para os modelos :Os termostatos - 33CS250-FS (406.84 kb)