Log:
Assessments - 3, GPA: 3.7 ( )

Instruções de Operação Bryant, Modelo TSTATBBN2S01-C

Fabricante : Bryant
Arquivo Tamanho: 63.68 kb
Arquivo Nome : iitstat-0-34.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


TO ADJUST: 1. Enter configuration mode (if not already there). 2. Use up and down buttons to display Option 01. The SET icon should be off. 3. Press MODE button once. The SET icon will come on. The display now shows Option 01 setting. 4. Use up and down buttons to move between the available Option 01 values of 1 to 9. Factory default is 3. 5. Press MODE button again to return to Option 01. The SET icon will now be off. 6. Use up and down buttons to select another Option, or press FAN button to exit configuration mode. B. Option 02—Clean Filter Timer This option selects the number of hours of blower operation (heating, cooling, or fan) before SERVICE FILTER icon is displayed. With OF selected, the icon will never come on, disabling this feature. Time selection can be from 400 to 3600 hours by selecting numbers 1 through 9. (Time is 400 X number selected.) Factory default is 2 (800 hours). Recommended selections are: disposable filter 800 hr, media filter 1200 to 1600 hr, or electronic air cleaner 1600 to 2400 hr of blower operation. TO ADJUST: 1. Enter configuration mode (if not already there). 2. Use up and down buttons to display Option 02. The SET icon should be off. 3. Press MODE button once. The SET icon will come on. The display now shows Option 02 setting. 4. Use up and down buttons to move between the available Option 02 values of OF and 1 through 9. Factory default is 2. 5. Press MODE button again to return to Option 02. The SET icon will now be off. 6. Use up and down buttons to select another Option, or press FAN button to exit configuration mode. C. Option 03—Fahrenheit/Celsius Selection This option selects Fahrenheit or Celsius operation. TO SELECT: 1. Enter configuration mode (if not already there). 2. Use up and down buttons to display Option 03. The SET icon should be off. 3. Press MODE button once. The SET icon will come on. The display now shows Option 03 setting. 4. Use up and down buttons to move between the available Option 03 choices of F (Fahrenheit) or C (Celsius). Factory default is F. 5. Press MODE button again to return to Option 03. The SET icon will now be off. 6. Use up and down buttons to select another Option, or press FAN button to exit configuration mode. D. Option 04—G (Fan) On With W/W1 Output This selection determines whether the G (fan) output is to be ON or OFF when any W (furnace or strip heat) output is ON. Most furnaces and fan coils manage their own blowers and do not require a separate G signal. For these applications, select OFF. Some auxiliary heaters require a separate G signal to turn on the blower. In this case, select On. Factory default is OF (off). TO SELECT: 1. Enter configuration mode (if not already there). 2. Use up and down buttons to display Option 04. The SET icon should be off. 3. Press MODE button once. The SET icon will come on. The display now shows Option 04 setting. 4. Use up and down buttons to move between available Option 04 choices of ON or OF. Factory default is OF. 5. Press MODE button again to return to Option 04. The SET icon will now be off. 6. Use up and down buttons to select another Option, or press FAN button to exit configuration mode. E. Option 05 — HP and 2S / AC Configuration This configuration is available on HP and 2S models only. Selecting AC allows the installer to use an HP or 2S thermostat in an AC application. TO SELECT: 1. Enter configuration mode (if not already there). 2. Use up and down buttons to display Option 05. The SET icon should be off. 3. Press MODE button once. The SET icon will come on. The display now shows Option 05 setting. 4. Use up and down buttons to move between available Option 05 choices of AC or HP. Factory default is HP. 5. Press MODE button again to return to Option 05. The SET icon will now be off. 6. Use up and down buttons to select another Option, or press FAN button to exit configuration mode. F. Option 06—Cooling Lockout An outdoor air sensor is required for this function. In OF mode, cooling is available regardless of outdoor temperature. In ON mode, cooling will not be initiated if the outdoor air temperature is below 55° F. If the compressor is already operating and the outdoor air temperature drops below 55° F, the compressor will continue to operate until the cooling cycle has completed. If the mode has been set to ON and the outdoor air sensor fails, an E3 error will be displayed. TO SELECT: 1. Enter configuration mode (if not already there). 2. Use up and down buttons to display Option 06. The SET icon should be off. 3. Press MODE button once. The SET icon will come on. The display now shows Option 06 setting. 4. Use up and down buttons to move between available Option 06 choices of OF or ON. Factory default is OF. 5. Press MODE button again to return to Option 06. The SET icon will now be off. 6. Use up and down buttons to select another Option, or press FAN button to exit configuration mode. G. Option 07—Zoning On/Off Configuration This selection enables or defeats the cycle timer...

Este manual também é adequado para os modelos :
Os termostatos - TSTATBBNAC01-C (63.68 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias