Log:
Assessments - 5, GPA: 3.8 ( )

Instruções de Operação Honeywell, Modelo 47350A

Fabricante : Honeywell
Arquivo Tamanho: 460.63 kb
Arquivo Nome : 47350.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


If you have a normal furnace or electric system, leave the switch in the Standard position. Refer to the System Selector section on the back for more information on this switch. ¦ Be sure to tighten the terminal screws securely, otherwise a loose wire could cause operational problems with your system or thermostat. ¦ Push excess wire back into the hole to prevent interference when installing the thermostat to the wallplate. ¦ Make sure the System Switch is set to OFF, and the Fan Switch is set to AUTO. ¦ Insert the bottom tab on the thermostat body into the slot at the bottom of the wallplate. Press the top of the thermostat body to snap it into the wallplate. Refer to Figure 6. (NOTE: Do not force the thermostat onto the wallplate, as the terminal pins may be damaged. If it does not snap properly, the thermostat may not work.) ¦ Insert the two AA size alkaline batteries, observing the polarity marked inside the battery compartment. ¦ Switch on the main power at the panel or furnace. x RH Figure 4 Figure 5 G Rc Rh Y/O W/B Y1 Figure 6 41659_model47350A_web.pmd 13 Selector Switches 13 In order for this Hunter thermostat to control your system, the system type must be specified by selector switches on the printed circuit board inside the thermostat. NOTE: When changing these features after installation, move the HEAT / COOL selector switch to OFF before removing the thermostat from the wall. System Selector Switches: ¦ Heating system selector (HG – HE switch) The factory position for this switch is in the “HG” position. Leave it in this position if you have a gas furnace or an oil burner. If you have an electric furnace, test to see whether the Heat and Fan come on as expected. If Fan operation is normal, leave the switch in the “HG” position. If the Fan does not come on within a minute of the thermostat calling for Heat, change the switch position to “HE.” The system selector has no effect in the cooling mode. NOTE: “HG” position is for gas and most other systems. “HE” position is for certain electric systems having a fan relay. ¦ Furnace or Heat Pump selector (STD - HP switch) The factory position for this switch is in the STD position. Leave it in this position if you have ANY system that uses gas, oil, electric, or hot water heating. If you have a single-stage Heat Pump (no auxiliary or emergency heat source), then slide the switch to the HP position. ¦ Auto Recovery selector (DISABLE / ENABLE) Your thermostat is set from the factory with the Auto Recovery Feature enabled, which complies with the EPA ENERGY STAR® Program. If you prefer to use normal recovery, slide the switch to the ALT position. Refer to page 32 for a complete discussion of the Auto Recovery feature. Figure 7 Fan Option (SW6) System Selector (SW5) DISABLE Auto Recovery ENABLE (SW2) STD HP HG HE 41659_model47350A_web.pmd 14 PROGRAMMING Setting Time and Day ¦ The LCD will show this information when batteries are first installed, or after the Reset button is pressed. The temperature will update after a few seconds. ¦ During time and day setting mode, the temperature and program displays will go blank. ¦ Example: Set the Thermostat to the current time of 2:16 pm on Saturday. Refer to the Steps below. M AM 4 TEMP STEP 1: STEP 2: day/time day/time 15 STEP 3: day/time STEP 4: day/time or ¦ Press to enter time and day setting mode. The cur-M rent hour and the AM / PM indicator will be flashing. AM ¦ Press to change the Hour up or down to the current hour. Note the AM / PM indicator, as the display will change at 12 AM and 12 PM. ¦ Press again to change from hour setting to minute setting. The current minute will be flashing. ¦ Press to change the Minute up or down to the current minute. PM M ¦ Press again to change from minute setting to day setting. The current day will be flashing. ¦ Press to change the Day up or down to the current day. PM M ¦ Press again to change back to the SA normal display. PM 2 hold TEMP /return NOTE: You may press hold at any time during Day and Time setting to return to the /return normal display. DAYLIGHT SAVING TIME day/time ¦ Press and hold. ¦ Press to enter Daylight Saving Time. or SA SET TEMP AM 2 TEMP (continued) 41659_model47350A_web.pmd 16 PROGRAMMING Setting Time and Day (continued) 12 HR. / 24 HR. TIME FORMAT Your thermostat is set from the factory in normal 12 (AM / PM) time format. To change to 24 hour (military) time, press program at any time while the Hour, Default Programs Minute, or Day is flashing to toggle between the 12 hour and 24 hour formats. The AM / PM indicator will not be displayed in 24 hour mode. Both the current time and all programs will automatically change to the selected format. Studies conducted by the Department of Energy esti-3°C (5°F) for two 8-hour periods during summer you mate that setting your thermostat back 6°C (10°F) for can reduce your fuel bill up to 25%. two 8-hour periods during winter can reduce your fuel Your Hunter thermostat is pre-programmed to meet bill by as much ...

Este manual também é adequado para os modelos :
Os termostatos - 47350A (460.63 kb)
Os termostatos - 47350A (460.63 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias