Log:
Assessments - 2, GPA: 5 ( )

Instruções de Operação Aprilaire, Modelo 8400

Fabricante : Aprilaire
Arquivo Tamanho: 1.32 mb
Arquivo Nome : 8400.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


61000651B 8400 Tstat Owners.indd 3 7/23/09 10:43:02 AM AbOUT yOUR NEw THERmOSTAT – NON-pROgRAmmAblE mODElS AbOUT yOUR NEw THERmOSTAT – NON-pROgRAmmAblE mODElS CONTROlS & DISplAy OVERVIEw – mODElS 8444, 8446, 8448 CURRENT INDOOR TEMPERATURE SySTEM MODE SETTINg SySTEM MODE (PAgE 6) FAN SETTINg (PAgE 7) FAN SETTINg BATTERy DOOR OUTDOOR TEMPERATURE (OPTIONAL) TEMPERATURE SETTINg EQUIPMENT STATUS UP DOWN HEAT pUmp mODElS ONly EMERgENCy HEAT (RED) SySTEM FAULT (yELLOW) INDICATOR SHOWS THROUgH HOUSINg QUICk REFERENCE CARD MESSAgE CENTER LOW BATTERy WARNINg (PAgE 7) NOTE: BACkLIgHT IS ACTIVATED WITH FIRST BUTTON PRESS AND AUTOMATICALLy TURNS OFF. 61000651B 8400 Tstat Owners.indd 4 7/23/09 10:43:02 AM AbOUT yOUR NEw THERmOSTAT – pROgRAmmAblE mODElS AbOUT yOUR NEw THERmOSTAT – pROgRAmmAblE mODElS CONTROlS & DISplAy OVERVIEw – mODElS 8463, 8465, 8466 CURRENT INDOOR TEMPERATURE CURRENT TIME SySTEM MODE SETTINg FAN SETTINg SySTEM MODE (PAgE 6) FAN SETTINg (PAgE 7) PROgRAM CURRENT SCHEDULE PERIOD (PAgE 8) BATTERy DOOR OUTDOOR TEMPERATURE (OPTIONAL) TEMPERATURE SETTINg EQUIPMENT STATUS UP DOWN HOLD HEAT pUmp mODElS ONly EMERgENCy HEAT (RED) SySTEM FAULT (yELLOW) INDICATOR SHOWS THROUgH HOUSINg QUICk REFERENCE CARD MESSAgE CENTER LOW BATTERy WARNINg (PAgE 7) NOTE: BACkLIgHT IS ACTIVATED WITH FIRST BUTTON PRESS AND AUTOMATICALLy TURNS OFF. 61000651B 8400 Tstat Owners.indd 5 7/23/09 10:43:02 AM OpERATION – All mODElS OpERATION – All mODElS SElECT SySTEm mODE (Off/HEAT/Em-HEAT/COOl/AUTO) Applies to programmable versions (8463, 8465, 8466) when in HOLD mode. CHANgE TEmpERATURE SETTINg 6 press to select: AUTO: Thermostat automatically selects heating or cooling depending on the indoor temperature. Off: Heating and cooling systems are off. HEAT: Thermostat controls only the heating system. COOl: Thermostat controls only the cooling system. Em-HEAT: Thermostat controls emergency/auxiliary heat. Heat pump will not operate. (only for heat pumps with auxiliary heat on models 8446, 8465, and 8466) press or In AUTO use COOL setting. to adjust the current setting. to switch between the HEAT and 61000651B 8400 Tstat Owners.indd 6 7/23/09 10:43:03 AM 7 Select fan setting (ON/AUTO/CIRC) Press to select: ON: Fan runs continuously. Use this mode for maximum air circulation/air cleaning. AUTO: Fan runs only when the heating or cooling system is on. CIRC: Same as AUTO, but if the fan has been off for 20 minutes the fan will be activated for a 10 minute cycle. Use this mode for a balance of energy savings and air circulation/cleaning. Operation – ALL MODELS Batter y insta llation and reset button The thermostat can either be AC or battery powered, or both. When wired to be AC powered, the batteries are optional and only provide backup power to the clock. The thermostat has a memory backup that saves the thermostat’s settings in case of a power interruption. The reset button located under the battery cover can be used to reset the thermostat back to factory defaults. RESET BUTTON Reset service reminder messages Press and hold and together for three seconds to reset a service reminder message. 61000651B 8400 Tstat Owners.indd 7 7/23/09 10:43:03 AM OpERATION & pROgRAmmINg – pROgRAmmAblE mODElS ONly (8463, 8465, 8466) OpERATION & pROgRAmmINg – pROgRAmmAblE mODElS ONly (8463, 8465, 8466) SET TImE AND DAy 1 press to enter time setting mode. Hour and AM/PM are flashing. 2 press or to adjust the hour. 3 press , the minutes flash. press or to adjust the minutes. 4. press , the day flashes. press or to adjust day. 5. press to end. “DONE” will display. The thermostat will return to normal mode if no key is pressed within 3 seconds. UNDERSTANDINg pROgRAm SCHEDUlES The daily schedule is split into four sections: wAKE: 6am-8am – Temperature you would prefer to wake up to, until you leave for the day. lEAVE: 8am-5pm – Temperature when you are away from the house during the day. RETURN: 5pm-10pm – Temperature you would prefer to return to, until bedtime. SlEEp: 10pm-6am – Temperature you would prefer during the night. The times shown are the defaults. The start time and temperature of each section can be changed to fit your schedule (see page 10). This thermostat is pre-set to use EnergyStar® program settings (see the chart that follows). We recommend these settings, since they can reduce your heating/ cooling expenses. 61000651B 8400 Tstat Owners.indd 8 7/23/09 10:43:05 AM OpERATION & pROgRAmmINg – pROgRAmmAblE mODElS ONly (8463, 8465, 8466) OpERATION & pROgRAmmINg – pROgRAmmAblE mODElS ONly (8463, 8465, 8466) UNDERSTANDINg pROgRAm SCHEDUlES (CONTINUED) Event Event designator Start time Set temps Heat Cool 1 WAkE 6:00AM 70°F (21°C) 78°F (26°C) 2 LEAVE 8:00AM 62°F (17°C) 85°F (29°C) 3 RETURN 5:00PM 70°F (21°C) 78°F (26°C) 4 SLEEP 10:00PM 62°F (17°C) 82°F (28°C) pROgRESSIVE RECOVERy The Progressive Recovery feature allows the thermostat Example: to activate the heating and cooling equipment prior to Set the Wake time to 6 am, and the temperature to 70°. an eve...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias