@name

4 I sic, pit ¡тшшт booie SALES REFERENCE (Supersedes PK428-4) PK428-5 161-048628-001 DATE OCTOBER, 1987 Chromalox General Purpose Industrial Thermostat Catalog Number PIT with Rain-Tight Enclosure Catalog Number PIT-EP with Explosion-Proof Enclosure Type PIT (rain-tight) a UL Listed Not a fail-safe device Type PIT-EP (explosion-proof) Specifications — Tabie A Catalog Number (RainTight; Catalog Number (Explosion Proof) Temp. Range (°F) Sensitive Buib with 10' Capillary V' &3. Nomi

Downloads : 11   Arquivo Tamanho: 397 kb   Fabricante : Chromalox  
Categoria : Os termostatos
@name

4 I sec, вот Inumber зоот REFERENCE PK451 161-058028-001 DATE DECEMBER, 1986 Chromalox Indicating Thermostat Control — Model BCT Model Numbers are listed below Model BCT-800 Figure 1 Specifications — Table A Thermal Element Dual Temp. Range Model Number Bulb end Cap Material Cep Length (FT) Bulb (IN) Dla. Length -40° to 1 20°F -40° to 50°C BCT-800-4BC BCT-802-4BC" Copper 6 % 6Й BCT-800-4BS BCT-802-4BS* Stainless Steel 6 % 6Й 0°F to 250 °F - 20° to 120°C BCT-B00-6BC ВСТ-Э

Downloads : 0   Arquivo Tamanho: 397 kb   Fabricante : Chromalox  
Categoria : Os termostatos
@name

Turning in lowers indicated reading. 5. Check adjustment by allowing temperature to stabilize and comparing readings. Repeat above steps if necessary. 6. Replace instrument cover and knob. Adjusting Single Switch Types (BCT-800 and 820E) 1. Remove knob and instrument cover, 2. Move the adjustment pointer up scale beyond the indicating pointer. This permits checking the set point by moving the lever arm upward with a finger or tool simulating thermal assembly movement. 3. Connect test ligh

Downloads : 11   Arquivo Tamanho: 301 kb   Fabricante : Chromalox  
Categoria : Os termostatos
@name

Specifications — Model PCN Temperature Range (°F) Volts Max Amps. Capillary Length (Ft.) Stock GNIT-5 360946 30 to 220 120/240 25 5 S GNIT-12 360954 30 to 220 120/240 25 12 S Other temperature ranges available. Contact your local Chromalox Sales office. GENERAL FIRE/EXPLOSION HAZARD. This thermostat is not intended for use in hazardous atmospheres where flammable vapors, gases, liquids or other combustible atmospheres are present as defined in the National Electrical Code. Failure to comply can

Downloads : 15   Arquivo Tamanho: 189 kb   Fabricante : Chromalox  
Categoria : Os termostatos
@name

2. Differential: 5.F. 3. Non-inductive Rating: 120V @ 25 Amperes 240V @ 25 Amperes 277V @ 22 Amperes LO HIOFFChromaloxR GENERAL The following procedure contains instructions for installing thermostat kits HVH-TK5 and HVH-TK6 in HVH-02 through HVH15 Heaters. ELECTRIC SHOCK HAZARD. Disconnect all power before installing thermostat kit. Failure to do so could result in personal injury or property damage. Thermostat kit must be installed by a qualified person in accordance with the National Electric

Downloads : 6   Arquivo Tamanho: 189 kb   Fabricante : Chromalox  
Categoria : Os termostatos
@name

} MotorBlueBlueOptional ThermostatBuilt in or field installedOptional Disconnect SwitchBuilt in or field installedPower60 HzElements1O Element Wiring(Omit for 2 ElementHeaters) CutoutTerminalBlockT1T3T2L1L3L2BlackBlackFigure 4 208-277V 1O — 2.6 & 5 kW WIRING DIAGRAMS (cont’d.) TO T1TO T1TO T2TO T3TO T3TO T2{ TRANSFORMER COLOR CODE INDEXVOLTLEAD CLRSLEAD CLRSLEAD CLRSX2BLUBLUBLUBLUBLUX2WHTWHTWHTWHTWHTH2REDORBRBLK/REDGRAYELBLKBLK575YELBLKBLK480YELBLKBLK277YELBLKBLK240YELBLKBLK208X1X1H124V SEC.120V

Downloads : 35   Arquivo Tamanho: 275 kb   Fabricante : Chromalox  
Categoria : Os termostatos
@name

Minimum capillary tube bending diameter is 1/2” I.D. (see Figure 4). Figure 3 (Sensing Bulb) 1” Do Not Bend or Kink Crimped End 1/2” Rod Figure 4 (Capillary Tube) C. Any deformations of bulb or capillary that result in leakage of fluid from control renders control inoperative. D. Avoid passing control capillary tube through zones whose temperature is in excess of controlled process temperature. Erratic control or destruction of control function may result. WIRING ELECTRIC SHOCK HAZARD. Disconect

Downloads : 7   Arquivo Tamanho: 241 kb   Fabricante : Chromalox  
Categoria : Os termostatos
@name

never above 150°F. 1. Thermostat must be mounted in a vertical position only. 2. Use sheet metal or wood screws through the four 7/32” diameter mounting holes in baseplate to mount control (see Figure 2). 3. For controlling platen or die temperatures, insert entire sensing bulb into drilled holes selected for snug slip fit. The longer, more sensitive Style 9 bulbs should be used for controlling air temperatures or pipe line heating. 4. NOTICE: A. Bending or deforming sensing bulb will alter cont

Downloads : 0   Arquivo Tamanho: 241 kb   Fabricante : Chromalox  
Categoria : Os termostatos
@name

Figure 3 (Sensing Bulb) Figure 4 (Capillary Tube) 1” 1/2” Rod Do Not Bend or Kink Crimped End D. Avoid passing control capillary tube through zones whose temperature is in excess of controlled process temperature. Erratic control or destruction of control function may result. WIRING 6. Connect wires according to wiring diagrams (Figures 8 thru 12). Note: Electrical connections should be made with gener- ELECTRIC SHOCK HAZARD. Disconect all power to ous loops of wire — approximately 6” per lead.

Downloads : 3   Arquivo Tamanho: 201 kb   Fabricante : Chromalox  
Categoria : Os termostatos
@name

CAUTION: Users should install adequate back-up controls and safety devices with their electric heating equipment. Where the consequences of failure may be severe, back-up controls are essential. Although the safety of the installation is the responsibility of the user, Chromalox will be glad to make equipment recommendations. Principle of Operation – Control action of these thermostats is provided through the principle of liquid volume change. With a variation in temperature, the liquid in the s