Log:
Assessments - 2, GPA: 5 ( )

Instruções de Operação Accusplit, Modelo AE790M

Fabricante : Accusplit
Arquivo Tamanho: 479.82 kb
Arquivo Nome : AE790M500DEC_Instructions_LONG.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Data Mode (AE760M & AE790M Model only) Press [MODE] until you enter DATA mode The mode message "DATA" will be shown for one to two seconds before the number of free memories is to be shown. FREE 95 LAP You can press [START] to scroll through all segments. The current segment will come first. RECALL {008} 2 0 0 1 SEG {002} 2 - 1 9 A 10: 15' 30 The header consisting of the date/time stamp will be shown. The number of laps in the segment will appear in the upper left while the segment number is displayed in the middle left. If the segment shown is not your desired segment, press [START] to reach the desired segment. The current segment will be accessed first, then it will cycle back to the 1st, then 2nd and so on. When you have found the segment you want, you can press [RECALL] button consecutively to read the lap records from the first to the last lap. RECALL {001} 0: 01' 00" 55 SEG SPLIT {002} 0: 00' 12" 86 LAP 0: 01' 00" 55 RUN As you continue to press [RECALL] during the display of the last lap, you can advance to the next segment by pressing [START], The front page of the segment will be shown. Say the next segment is SEG 1. RECALL {012} 2 0 0 1 SEG {001} 2 - 1 8 A 10: 00' 15 How to delete individual memory segments: Search the desired segment first as described above. During the display of the segment front page, press [RESET] for 2 seconds to activate Delete One function. "DELETE ONE" will be shown in blinking and beep sound will be generated. dELETE OnE A "ready" period of 2 seconds will be counted. At the end of the ready period, all the lap records of the corresponding segment will be erased. And a long beep sound will be heard. Then the display will show the next segment. If you don't want to delete the records, you can press any key to exit from delete ready state before the end of the ready period and resume the display of the segment front page. How to delete all memory segments: Instead of deleting one segment, you can also delete all memory segments. When you enter the Data mode, you see the screen "FREE XXX LAP". Press and hold the [RESET] for 3 seconds.You will hear "Beep, beep, beep" for 3 seconds, then a long "Beep". At this point all data in the memory will be deleted and "DELETE ALL " will show on the display. If you don't want to delete the records, you can press any key to exit "DELETE ALL " state before the end of the ready period and resume the display of the segment front page. dELETE ALL Timer Mode Press [MODE] until you enter the Timer mode. 3 count-down operation modes are available on this stopwatch: -Count down repeat ( CR ) -Count down stop ( CS ) -Count down, then count up ( CU ) The timer is set at the factory to the count-down repeat (CR) mode. At entering timer mode, the mode message "TIMER" will be shown for a second before the timer counting is to be displayed. {000} 0: 00' 00" 0 CR 0: 00' 00" 0 A 12 : 58' 20 The upper line shows the programmable timer value (initially set at 0:00:00:0) while the middle line displays the current timer counting. Time of Day clock display is at the lower line of the display. "CR" indicates the current timer operating mode while the timer cycle counter is located at the upper left of the display. Before starting the timer, enter a countdown time first. Then press [START] to start timer running. When the timer counts down to zero, a 3 second "beep ... beep" sound will be generated for a timer setting within one minute; 15 second "beep ... beep" sound for 1 minute to 10 minutes setting and 30 second "beep ... beep" sound for over 10 minutes. Pressing any key will stop the beep sound. Under CR operation mode, the timer value will be reloaded and count down will start again. The timer cycle 12 counter will be increased by one and updated on the display. Under CS operation mode, the timer, after counting down to 0:00'00", will stay at 0:00'00"0 until you press [RESET] to reload the timer value. Under CU operation mode, the timer, after counting down to 0:00'00"0, will count up and stop at 19:59'59"9. How to set the timer Press and hold [RECALL] for 2 seconds to activate timer setting. Timer setting starts with second digits, which are shown blinking. You can press [START] to advance the flashing digits. Or you can press [RESET] to select other digits. The setting is in sequence of second, minute, hour and timer operating mode (CR, CS and CU). NOTE: You can only set Hour, Minute and Seconds. The 1/10 second cannot be set. Press and hold [RECALL] for 2 seconds. Timer setting starts with second digits. Press [RESET] to move to minute digits. Press [RESET] further to go to hour digits. Hour digits can be adjusted from 0 to 19. {000} 0: 00' 00" 0 CR 0: 00' 00" 0 A 12 : 58' 55 {000} 0: 00' 00" 0 CR 0: 00' 00" 0 A 12 : 58' 57 {000} 0: 00' 00" 0 CR 0: 00' 00" 0 A 12 : 59' 02 Press [RESET] again to adjust the operating mode. Press [START] to switch the operating modes among CR, CS and CU. {000} 0: 00' 00" 0 CR 0: 00' 00" 0 A 12 : 59' 11 At the end of sett...

Este manual também é adequado para os modelos :
Monitores de pressão arterial - AE760M (479.82 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias