Standard long-life or rechargeable battery used to power the FR2+. (Check local regulations for disposal and recycling requirements.) On/Off button. Turns on the FR2+ and starts voice and screen prompts. Second press turns off the FR2+. Status Indicator. Shows you the readiness status of the FR2+. Display screen. Displays text prompts and incident data. The FR2+ M3860A screen also displays the patient’s ECG. Option buttons. Adjust the contrast of the screen display and control special functions. Beeper port. Broadcasts alert beeps when required. It is located under the right edge of the FR2+. Infrared (IR) communications port. A special lens, or “eye,” used to transfer data directly to or from another device. Data card port. Receptacle for data card tray. Data card (optional). Used to store and review information about an incident, including ECG and optional voice recording. Data card tray. Special sleeve that holds the data card and fits into the data card port to help seal the FR2+ against fluids. The tray should be kept installed in the FR2+ even if no data card is used. Microphone. Used optionally to record surrounding audio during an incident. It is located under the right edge of the FR2+. Shock button. Controls shock delivery. The button flashes when the HeartStart FR2+ is ready to deliver a shock. Speaker. Amplifies voice prompts during use of the FR2+. Pads placement diagram. Illustrates correct placement of pads. Diagrams are also shown on the defibrillator pads. Defibrillator pads connector socket. Receptacle for connector of the defibrillator pads cable. An adjacent LED light flashes to show socket location and is covered when connector is inserted. Adult defibrillator pads. Selfadhesive pads with attached cable and connector. A B C D E F G H I J K L M N O P P h ili ps Me dic a l Sy s t em s HEARTSTART FR2+ DEFIBRILLATOR QUICK REFERENCE CARD Intentionally left blank. Philips Medical Systems Philips Medical Systems HEARTSTART FR2+ M3860A, M3861A Defibrillator INSTRUCTIONS FOR USE Edition 10 Instructions for Use Equipment specifications are subject to alteration without notice. All changes will be in compliance with regulations governing manufacture of medical equipment. Printed in the U.S.A. Publication date: August 2003 Publication number: M3860-91900 Part number: 011120-0010 © 2003 Philips Electronics North America Corp. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system or translated into any human or computer language in any form by any means without the consent of the copyright holder. Unauthorized copying of this publication may not only infringe copyright but also reduce the ability of Philips Medical Systems to provide accurate and up-to-date information to users and operators alike. Philips Medical Systems reserves the right to make changes in specifications or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. Authorized EU Representative Philips Medizinsysteme Boeblingen GmbH Hewlett-Packard Strasse 2 71034 Boeblingen, Germany (+49) 7031-14-5151 CAUTION FEDERAL LAW (USA) RESTRICTS THIS DEVICE TO SALE BY OR ON THE ORDER OF A PHYSICIAN. The HeartStart FR2+ is designed to be used only with Philipsapproved accessories. The HeartStart FR2+ may perform improperly if non-approved accessories are used. Device Tracking In the U.S.A., this device is subject to tracking requirements by the manufacturer and distributors. If the defibrillator has been sold, donated, lost, stolen, exported, or destroyed, notify Philips Medical Systems or your distributor. Device Manufacturer The HeartStart FR2+ Defibrillator is manufactured by Philips Medical Systems, Seattle, Washington, USA. M3860A/M3861A HEARTSTART FR2+ Philips Medical Systems Philips Medical Systems Contents 1 Introduction to the HeartStart FR2+ What is the HeartStart FR2+? ................................................................. 1-1 When Is the HeartStart FR2+ Used? .................................................... 1-2 How Does the HeartStart FR2+ Work? ................................................ 1-2 How Is the HeartStart FR2+ Supplied? ................................................ 1-3 2 Preparing Your HeartStart FR2+ for Use Overview ....................................................................................................... 2-1 Installing the Battery ................................................................................... 2-1 Setting the Clock ........................................................................................ 2-3 Running the Battery Insertion Selftest .................................................... 2-4 Placing and Securing the HeartStart FR2+ .......................................... 2-5 3 Using Your HeartStart FR2+ Overview ....................................................................................................

Este manual também é adequado para os modelos :
Monitores de pressão arterial - M3860A (1.83 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias