Instruções de Operação Omega Engineering, Modelo DPG1100B

Fabricante : Omega Engineering
Arquivo Tamanho: 191.18 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Entering the Calibration Mode a. Remove the back cover and note the locations of the two internal calibration pushbuttons marked UP and DOWN. These buttons are disabled unless the gauge is in calibration mode. b. With the gauge off, press and hold the DOWN calibration button, and also press the front button to power up the gauge in calibration mode. 2. Calibration Mode Functions a. The display first indicates the gauge’s full-scale pressure range, tests all display segments, and then indicates CAL to indicate that the gauge is in the calibration mode. Release all pushbuttons. b. The display will then indicate the current pressure reading, updating approximately 3 times per second. The gauge will remain in the calibration mode until powered down or reset manually. While in the calibration mode, the shutoff timer, One Touch Zero (gauge reference models only), Min/Max (for applicable models) are all disabled, and the calibration pushbuttons are active. c. Each press of the UP or DOWN button makes a small correction, which may not always be indicated on the digital display. Press and hold the pushbutton for one second or longer to make larger continuous corrections. The display of the gauge being calibrated is adjusted to match the calibrator’s setting or readout. d. If the battery pack is unplugged or the power removed during calibration, calibration settings will not be saved. 3. Gauge Reference Gauges (3 Points) a. With the gauge port open to atmosphere, the character display will alternate between ZERO and CAL. Press the UP and DOWN buttons to obtain a display indication of zero. b. Apply full-scale pressure. The character display will alternate between +SPAN and CAL. Press the UP and DOWN buttons to obtain a display indication equal to full-scale pressure. c. Apply 50% of full-scale pressure. The character display will alternate between +MID and CAL. Press the UP and DOWN buttons to obtain a display indication equal to 50% of full-scale pressure. 4. Exit Calibration Mode and Verify Calibration a. Exit the calibration mode and save the calibration data by pressing and holding the front button until the display indicates OFF. b. Verify pressure indications at 0%, 25%, 50%, 75%, and 100% of full scale. c. Replace the rear cover and screws, taking care not to pinch the power leads between the case and the rear cover. OMEGAnet® Online Service Internet e-mail info@omega.com OMEGAnet® Online Service Internet e-mail info@omega.com Servicing North America: USA: One Omega Drive, Box 4047 ISO 9001 Certified Stamford CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: USA and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA® Customer Service: 1-800-622-2378 / 1-800-622-BEST® Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN® TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA Mexico: En Espan.ol: (001) 203-359-7803 e-mail:espanol@omega.com FAX: (001) 203-359-7807 info@omega.com.mx Servicing Europe: Benelux: Postbus 8034, 1180 LA Amstelveen, The Netherlands Tel: +31 (0)20 3472121 FAX: +31 (0)20 6434643 Toll Free in Benelux: 0800 0993344 e-mail: sales@omegaeng.nl Czech Republic: Frystatska 184, 733 01 Karvina, Czech Republic Tel: +420 (0)59 6311899 FAX: +420 (0)59 6311114 Toll Free: 0800-1-66342 e-mail: info@omegashop.cz France: 11, rue Jacques Cartier, 78280 Guyancourt, France Tel: +33 (0)1 61 37 2900 FAX: +33 (0)1 30 57 5427 Toll Free in France: 0800 466 342 e-mail: sales@omega.fr Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany Tel: +49 (0)7056 9398-0 FAX: +49 (0)7056 9398-29 Toll Free in Germany: 0800 639 7678 e-mail: info@omega.de United Kingdom: One Omega Drive, River Bend Technology Centre ISO 9002 Certified Northbank, Irlam, Manchester M44 5BD United Kingdom Tel: +44 (0)161 777 6611 FAX: +44 (0)161 777 6622 Toll Free in United Kingdom: 0800-488-488 e-mail: sales@omega.co.uk It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification. The information contained in this document is believed to be correct, but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, human applications. WARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purcha...

Este manual também é adequado para os modelos :
Monitores de pressão arterial - DPG1000B (191.18 kb)
Monitores de pressão arterial - DPG1000BBL (191.18 kb)
Monitores de pressão arterial - DPG1001B (191.18 kb)
Monitores de pressão arterial - DPG1100BBL (191.18 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias