Instruções de Operação HoMedics, Modelo IB-BPA060A

Fabricante : HoMedics
Arquivo Tamanho: 1.34 mb
Arquivo Nome :
Língua de Ensino: enes
Ir para baixar



Facilidade de uso


23 CARE, MAINTENANCE & CLEANING 1. Clean the blood pressure monitor body and cuff carefully with a slightly damp, soft cloth. Do not press. Do not wash cuff or use chemical cleaner on it. Never use thinner, alcohol or petrol (gasoline) as cleaner. 2. Leaky batteries can damage the unit. Remove the batteries when the unit will not be used for a long time. 3. If the unit is stored near freezing, allow it to acclimate to room temperature before use. 4. This blood pressure monitor is not field serviceable. You should not use any tool to open the device nor should you attempt to adjust anything inside the device. If you have any problems with this device, please contact HoMedics Consumer Relations (contact information can be found on the warranty page). 5. Do not immerse the unit in water as this will result in damage to the unit. 6. Do not subject the monitor and cuff to extreme temperatures, humidity, moisture, and direct sunlight. Protect from dust. 7. Do not fold the cuff and tubing tightly. 8. Do not disassemble the monitor or cuff. If in need of repair, refer to the warranty section of this manual. 9. Do not subject the monitor to extreme shocks (do not drop on floor). 24 10. Do not inflate the cuff unless wrapped around arm. 11. Do not wrap the cuff around body parts other than your arm. 12. Do not drop or insert any object into any opening or hose. 13. To avoid accidental strangulation, keep this product away from children and do not drape tube around neck. 14. This monitor may not meet its performance specifications if stored or used outside of these temperature and humidity ranges: • Storage Environment • Operating Environment Temperature: Temperature: -4°F~140°F (-20°C~60°C) 50°F~104°F (10°C ~40°C) Humidity:Humidity: less than 85% RH less than 85% RH POTENTIAL FOR ELECTROMAGNETIC INTERFERENCE To avoid inaccurate results caused by electromagnetic interference between electrical and electronic equipments, do not use the device near a cell phone or microwave oven. 25 26 TROUBLESHOOTING SPECIFICATIONS If any abnormality arises during use, please check the following points SYMPTOMS POSSIBLE CAUSES CORRECTION Unit does not turn on when the START/STOP button is pushed. Batteries have run down. Replace them with four new AA alkaline batteries. Battery polarities have been positioned incorrectly. Re-insert the batteries in the correct positions. EE measurement error symbol shown on display or the blood pressure value is displayed excessively low (or high). Cuff has been placed incorrectly. Wrap the cuff properly so that it is positioned correctly. Did you talk or move during measurement? Measure again. Keep arm steady during measurement.Shaking of the arm with the cuff on. E1 error symbol shown on display Air circuit abnormality. Cuff tube may not be plugged into monitor correctly. Check cuff connection. Measure again. E2 error symbol shown on display Inflation pressure exceeding 300 mmHg. Switch the unit off, then measure again. E3 error symbol shown on display Error determining measurement data. Measure again. Note: If the unit still does not work, contact HoMedics Consumer Relations. Under no circumstance should you disassemble or attempt to repair the unit by yourself. Contact information for HoMedics Consumer Relations Department can be found on the warranty page. Power Source: Four 1.5V DC (AA) batteries or 6V DC AC adapter (NOT INCLUDED) Measurement Method: Oscillometric Measurement Range: Pressure: 40~280 millimeters mercury (mmHg) Pulse: 40~199 beats/minute Accuracy: Pressure: ±3 mmHg Pulse: ±5% of reading Pressure Sensor: Semi-conductor Inflation: Pump driven Deflation: Automatic Pressure release valve Memory Capacity: 50 memories for each User (100 total) Auto-shut-off: 1 minute after last button operation Operation Environment: Temperature: 50°F~104°F (10°C ~40°C) Humidity: Less Than 85% RH Storage Environment: Temperature: -4°F~140°F (-20°C~60°C) Humidity: Less Than 85% RH Weight: 0.72 lb (325 g) (without batteries) Arm Circumference: Standard size cuff: 9"–13" (23-33 cm) Large size cuff:13"–17" (33-43 cm) Dimensions: 5.9"(L) x 4.4"(W) x 2.2"(H) 149mm(L) x 111.5mm(W) x 57mm(H) Internally Powered equipment. Type BF Equipment. IPx0-No special protection against the ingress of water. Not suitable for use in presence of flammable anesthetic mixture with air, oxygen or nitrous oxide. Continuous operation with short-time loading. Note: These specifications are subject to change without notice. 27 28 - -- - -- BPA-060 INDICE INFORMACION INICIAL: Avisos importantes del producto e instrucciones de seguridad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 Sobre la presion sanguinea . . . . . . . . . . . . . . . . . . .35 .Que es la presion sanguinea? .Por que medir la presion sanguinea? Estandar de presion sanguinea . . . . . . . . . . . . . . .35 Como funciona este monitor de presion sanguinea . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37 INFORMACION DE USO: Nombre/Fun...

Este manual também é adequado para os modelos :
Monitores de pressão arterial - BPA-060 (1.34 mb)
Monitores de pressão arterial - PP-BPCUFF5 (1.34 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias